Gas hydrate and free gas detection using seismic quality factor estimates from high-resolution P-cable 3D seismic data
Source at http://dx.doi.org/10.1190/INT-2015-0023.1 . Reuse is subject to Society of Exploration Geophysicists terms of use and conditions. We have estimated the seismic attenuation in gas hydrate and free-gas-bearing sediments from high-resolution P-cable 3D seismic data from the Vestnesa Ridge on...
Published in: | Interpretation |
---|---|
Main Authors: | , , , |
Format: | Article in Journal/Newspaper |
Language: | English |
Published: |
Society of Exploration Geophysicists
2015
|
Subjects: | |
Online Access: | https://hdl.handle.net/10037/10762 https://doi.org/10.1190/INT-2015-0023.1 |
_version_ | 1829303339428347904 |
---|---|
author | Singhroha, Sunny Bünz, Stefan Plaza-Faverola, Andreia Chand, Shyam |
author_facet | Singhroha, Sunny Bünz, Stefan Plaza-Faverola, Andreia Chand, Shyam |
author_sort | Singhroha, Sunny |
collection | University of Tromsø: Munin Open Research Archive |
container_issue | 1 |
container_start_page | SA39 |
container_title | Interpretation |
container_volume | 4 |
description | Source at http://dx.doi.org/10.1190/INT-2015-0023.1 . Reuse is subject to Society of Exploration Geophysicists terms of use and conditions. We have estimated the seismic attenuation in gas hydrate and free-gas-bearing sediments from high-resolution P-cable 3D seismic data from the Vestnesa Ridge on the Arctic continental margin of Svalbard. P-cable data have a broad bandwidth (20–300 Hz), which is extremely advantageous in estimating seismic attenuation in a medium. The seismic quality factor (Q), the inverse of seismic attenuation, is estimated from the seismic data set using the centroid frequency shift and spectral ratio (SR) methods. The centroid frequency shift method establishes a relationship between the change in the centroid frequency of an amplitude spectrum and the Q value of a medium. The SR method estimates the Q value of a medium by studying the differential decay of different frequencies. The broad bandwidth and short offset characteristics of the P-cable data set are useful to continuously map the Q for different layers throughout the 3D seismic volume. The centroid frequency shift method is found to be relatively more stable than the SR method. Q values estimated using these two methods are in concordance with each other. The Q data document attenuation anomalies in the layers in the gas hydrate stability zone above the bottom-simulating reflection (BSR) and in the free gas zone below. Changes in the attenuation anomalies correlate with small-scale fault systems in the Vestnesa Ridge suggesting a strong structural control on the distribution of free gas and gas hydrates in the region. We argued that high and spatially limited Q anomalies in the layer above the BSR indicate the presence of gas hydrates in marine sediments in this setting. Hence, our workflow to analyze Q using high-resolution P-cable 3D seismic data with a large bandwidth could be a potential technique to detect and directly map the distribution of gas hydrates in marine sediments |
format | Article in Journal/Newspaper |
genre | Arctic Arctic Svalbard |
genre_facet | Arctic Arctic Svalbard |
geographic | Arctic Svalbard |
geographic_facet | Arctic Svalbard |
id | ftunivtroemsoe:oai:munin.uit.no:10037/10762 |
institution | Open Polar |
language | English |
op_collection_id | ftunivtroemsoe |
op_container_end_page | SA54 |
op_doi | https://doi.org/10.1190/INT-2015-0023.1 |
op_relation | Singhroha, S. (2019). Distribution and quantification of gas hydrates and free gas in marine sediments of Vestnesa Ridge, offshore W-Svalbard. (Doctoral thesis). https://hdl.handle.net/10037/15824 . Interpretation info:eu-repo/grantAgreement/RCN/SFF/223259/Norway/Centre for Arctic Gas Hydrate, Environment and Climate/CAGE FRIDAID 1329455 https://hdl.handle.net/10037/10762 |
op_rights | openAccess |
publishDate | 2015 |
publisher | Society of Exploration Geophysicists |
record_format | openpolar |
spelling | ftunivtroemsoe:oai:munin.uit.no:10037/10762 2025-04-13T14:11:51+00:00 Gas hydrate and free gas detection using seismic quality factor estimates from high-resolution P-cable 3D seismic data Singhroha, Sunny Bünz, Stefan Plaza-Faverola, Andreia Chand, Shyam 2015-09-23 https://hdl.handle.net/10037/10762 https://doi.org/10.1190/INT-2015-0023.1 eng eng Society of Exploration Geophysicists Singhroha, S. (2019). Distribution and quantification of gas hydrates and free gas in marine sediments of Vestnesa Ridge, offshore W-Svalbard. (Doctoral thesis). https://hdl.handle.net/10037/15824 . Interpretation info:eu-repo/grantAgreement/RCN/SFF/223259/Norway/Centre for Arctic Gas Hydrate, Environment and Climate/CAGE FRIDAID 1329455 https://hdl.handle.net/10037/10762 openAccess VDP::Matematikk og Naturvitenskap: 400::Geofag: 450 VDP::Mathematics and natural science: 400::Geosciences: 450 Journal article Tidsskriftartikkel Peer reviewed 2015 ftunivtroemsoe https://doi.org/10.1190/INT-2015-0023.1 2025-03-14T05:17:55Z Source at http://dx.doi.org/10.1190/INT-2015-0023.1 . Reuse is subject to Society of Exploration Geophysicists terms of use and conditions. We have estimated the seismic attenuation in gas hydrate and free-gas-bearing sediments from high-resolution P-cable 3D seismic data from the Vestnesa Ridge on the Arctic continental margin of Svalbard. P-cable data have a broad bandwidth (20–300 Hz), which is extremely advantageous in estimating seismic attenuation in a medium. The seismic quality factor (Q), the inverse of seismic attenuation, is estimated from the seismic data set using the centroid frequency shift and spectral ratio (SR) methods. The centroid frequency shift method establishes a relationship between the change in the centroid frequency of an amplitude spectrum and the Q value of a medium. The SR method estimates the Q value of a medium by studying the differential decay of different frequencies. The broad bandwidth and short offset characteristics of the P-cable data set are useful to continuously map the Q for different layers throughout the 3D seismic volume. The centroid frequency shift method is found to be relatively more stable than the SR method. Q values estimated using these two methods are in concordance with each other. The Q data document attenuation anomalies in the layers in the gas hydrate stability zone above the bottom-simulating reflection (BSR) and in the free gas zone below. Changes in the attenuation anomalies correlate with small-scale fault systems in the Vestnesa Ridge suggesting a strong structural control on the distribution of free gas and gas hydrates in the region. We argued that high and spatially limited Q anomalies in the layer above the BSR indicate the presence of gas hydrates in marine sediments in this setting. Hence, our workflow to analyze Q using high-resolution P-cable 3D seismic data with a large bandwidth could be a potential technique to detect and directly map the distribution of gas hydrates in marine sediments Article in Journal/Newspaper Arctic Arctic Svalbard University of Tromsø: Munin Open Research Archive Arctic Svalbard Interpretation 4 1 SA39 SA54 |
spellingShingle | VDP::Matematikk og Naturvitenskap: 400::Geofag: 450 VDP::Mathematics and natural science: 400::Geosciences: 450 Singhroha, Sunny Bünz, Stefan Plaza-Faverola, Andreia Chand, Shyam Gas hydrate and free gas detection using seismic quality factor estimates from high-resolution P-cable 3D seismic data |
title | Gas hydrate and free gas detection using seismic quality factor estimates from high-resolution P-cable 3D seismic data |
title_full | Gas hydrate and free gas detection using seismic quality factor estimates from high-resolution P-cable 3D seismic data |
title_fullStr | Gas hydrate and free gas detection using seismic quality factor estimates from high-resolution P-cable 3D seismic data |
title_full_unstemmed | Gas hydrate and free gas detection using seismic quality factor estimates from high-resolution P-cable 3D seismic data |
title_short | Gas hydrate and free gas detection using seismic quality factor estimates from high-resolution P-cable 3D seismic data |
title_sort | gas hydrate and free gas detection using seismic quality factor estimates from high-resolution p-cable 3d seismic data |
topic | VDP::Matematikk og Naturvitenskap: 400::Geofag: 450 VDP::Mathematics and natural science: 400::Geosciences: 450 |
topic_facet | VDP::Matematikk og Naturvitenskap: 400::Geofag: 450 VDP::Mathematics and natural science: 400::Geosciences: 450 |
url | https://hdl.handle.net/10037/10762 https://doi.org/10.1190/INT-2015-0023.1 |