Low emission geothermal power plants with absorption and reinjection of non-condensable gases

The gas content in the steam produced by some Italian geothermal fields is far from negligible, being around 5-10%. Several abatement methods are available to reduce the hydrogen sulfide and mercury emissions in dry steam and flash geothermal power plants, most of them relying on the use of chemical...

Full description

Bibliographic Details
Main Authors: Giovanni Manente, Andrea Lazzaretto, Alessio Bardi, Marco Paci, BERTANI, RUGGERO
Other Authors: José Carlos Teixeira, Manente, Giovanni, Lazzaretto, Andrea, Alessio, Bardi, Marco, Paci, Bertani, Ruggero
Format: Conference Object
Language:English
Published: Universidade do Minho, Departamento de Engenharia Mecânica, Campus Azurém, Guimarães Portugal 2018
Subjects:
Online Access:http://hdl.handle.net/11577/3279422
_version_ 1821557621034844160
author Giovanni Manente
Andrea Lazzaretto
Alessio Bardi
Marco Paci
BERTANI, RUGGERO
author2 José Carlos Teixeira
Manente, Giovanni
Lazzaretto, Andrea
Alessio, Bardi
Marco, Paci
Bertani, Ruggero
author_facet Giovanni Manente
Andrea Lazzaretto
Alessio Bardi
Marco Paci
BERTANI, RUGGERO
author_sort Giovanni Manente
collection Padua Research Archive (IRIS - Università degli Studi di Padova)
description The gas content in the steam produced by some Italian geothermal fields is far from negligible, being around 5-10%. Several abatement methods are available to reduce the hydrogen sulfide and mercury emissions in dry steam and flash geothermal power plants, most of them relying on the use of chemicals. Recently, the reinjection of H2S in the reservoir was tested in Iceland, a country having limited amounts of non-condensable gases (NCG) in the geothermal reservoirs. The reinjection of NCG in the Italian geothermal fields raises new challenges due to the high content of NCG, especially in the Mt. Amiata area. This paper examines the viability of NCG absorption and reinjection in retrofitting a geothermal plant fed by steam with a high NCG content (8%). The proposed layout includes an absorption column, in place of the AMIS® unit equipping the existing power stations, where H2S and CO2 are absorbed in water at high pressure. From preliminary calculations carried out in Aspen Plus®, it appears that the reinjection of the entire flow of NCG asks for considerable amounts of water and very high pressures (>100 bar). Thus, the study searches for those conditions ensuring an overall H2S abatement similar to that achieved by the plants equipped with the AMIS® unit (>90%), while minimizing the water and power demands. The results show that an overall H2S abatement of 86.4% could be reached using a column pressure of 36 bar and a water supply of 100 ton/hr, and coping with a net power output reduction of 6%. A further increase of H2S abatement in order to match the same performance of the AMIS® plant would lead to more demanding operating conditions in terms of water consumption and power penalty. The 50% abatement of the CO2 in the geothermal fluid is certainly a positive side effect.
format Conference Object
genre Iceland
genre_facet Iceland
id ftunivpadovairis:oai:www.research.unipd.it:11577/3279422
institution Open Polar
language English
op_collection_id ftunivpadovairis
op_relation info:eu-repo/semantics/altIdentifier/isbn/978-972-99596-4-6
ispartofbook:ECOS 2018 - Proceedings of the 31 st International Conference on Efficiency, Cost, Optimisation, Simulation and Environmental Impact of Energy Systems
ECOS 2018 - 31st International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems
firstpage:1
lastpage:12
numberofpages:12
http://hdl.handle.net/11577/3279422
publishDate 2018
publisher Universidade do Minho, Departamento de Engenharia Mecânica, Campus Azurém, Guimarães Portugal
record_format openpolar
spelling ftunivpadovairis:oai:www.research.unipd.it:11577/3279422 2025-01-16T22:40:48+00:00 Low emission geothermal power plants with absorption and reinjection of non-condensable gases Giovanni Manente Andrea Lazzaretto Alessio Bardi Marco Paci BERTANI, RUGGERO José Carlos Teixeira Manente, Giovanni Lazzaretto, Andrea Alessio, Bardi Marco, Paci Bertani, Ruggero 2018 ELETTRONICO http://hdl.handle.net/11577/3279422 eng eng Universidade do Minho, Departamento de Engenharia Mecânica, Campus Azurém, Guimarães Portugal info:eu-repo/semantics/altIdentifier/isbn/978-972-99596-4-6 ispartofbook:ECOS 2018 - Proceedings of the 31 st International Conference on Efficiency, Cost, Optimisation, Simulation and Environmental Impact of Energy Systems ECOS 2018 - 31st International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems firstpage:1 lastpage:12 numberofpages:12 http://hdl.handle.net/11577/3279422 Geothermal power plants Non-condensable gases Environmental impact Hydrogen sulphide Water absorption info:eu-repo/semantics/conferenceObject 2018 ftunivpadovairis 2023-08-22T05:31:52Z The gas content in the steam produced by some Italian geothermal fields is far from negligible, being around 5-10%. Several abatement methods are available to reduce the hydrogen sulfide and mercury emissions in dry steam and flash geothermal power plants, most of them relying on the use of chemicals. Recently, the reinjection of H2S in the reservoir was tested in Iceland, a country having limited amounts of non-condensable gases (NCG) in the geothermal reservoirs. The reinjection of NCG in the Italian geothermal fields raises new challenges due to the high content of NCG, especially in the Mt. Amiata area. This paper examines the viability of NCG absorption and reinjection in retrofitting a geothermal plant fed by steam with a high NCG content (8%). The proposed layout includes an absorption column, in place of the AMIS® unit equipping the existing power stations, where H2S and CO2 are absorbed in water at high pressure. From preliminary calculations carried out in Aspen Plus®, it appears that the reinjection of the entire flow of NCG asks for considerable amounts of water and very high pressures (>100 bar). Thus, the study searches for those conditions ensuring an overall H2S abatement similar to that achieved by the plants equipped with the AMIS® unit (>90%), while minimizing the water and power demands. The results show that an overall H2S abatement of 86.4% could be reached using a column pressure of 36 bar and a water supply of 100 ton/hr, and coping with a net power output reduction of 6%. A further increase of H2S abatement in order to match the same performance of the AMIS® plant would lead to more demanding operating conditions in terms of water consumption and power penalty. The 50% abatement of the CO2 in the geothermal fluid is certainly a positive side effect. Conference Object Iceland Padua Research Archive (IRIS - Università degli Studi di Padova)
spellingShingle Geothermal power plants
Non-condensable gases
Environmental impact
Hydrogen sulphide
Water absorption
Giovanni Manente
Andrea Lazzaretto
Alessio Bardi
Marco Paci
BERTANI, RUGGERO
Low emission geothermal power plants with absorption and reinjection of non-condensable gases
title Low emission geothermal power plants with absorption and reinjection of non-condensable gases
title_full Low emission geothermal power plants with absorption and reinjection of non-condensable gases
title_fullStr Low emission geothermal power plants with absorption and reinjection of non-condensable gases
title_full_unstemmed Low emission geothermal power plants with absorption and reinjection of non-condensable gases
title_short Low emission geothermal power plants with absorption and reinjection of non-condensable gases
title_sort low emission geothermal power plants with absorption and reinjection of non-condensable gases
topic Geothermal power plants
Non-condensable gases
Environmental impact
Hydrogen sulphide
Water absorption
topic_facet Geothermal power plants
Non-condensable gases
Environmental impact
Hydrogen sulphide
Water absorption
url http://hdl.handle.net/11577/3279422