PM-3A Nuclear Power Plant Secondary Shield Design

"The design, analysis, and selection of system components for functions related to secondary shielding and associated auxiliary systems for the Antarctic PM-3A Nuclear Power Plant are described. Backfill material characteristics, shielding and activation analyses, heat transfer analysis, backfi...

Full description

Bibliographic Details
Main Author: Siler, W C
Other Authors: {{{lab/organization}}}, U.S. Atomic Energy Commission. New York Operations Office.
Format: Report
Language:English
Published: United States. Government Printing Office. 1961
Subjects:
Online Access:https://digital.library.unt.edu/ark:/67531/metadc1463653/
Description
Summary:"The design, analysis, and selection of system components for functions related to secondary shielding and associated auxiliary systems for the Antarctic PM-3A Nuclear Power Plant are described. Backfill material characteristics, shielding and activation analyses, heat transfer analysis, backfill cooling system, water exclusion and removal system, and instrumentation and control are discussed."