Analysis of Oxygen Injection in the Keewatin Taconite Kiln Transfer Chute Using Medusa Heat and Mass Balance Simulation and Mini-Pot Firing Tests
Final Report For Minnesota Department of Natural Resources Iron Ore Cooperative Research Performance of the Medusa modeling and simulation of the Keewatin Taconite Line 2 furnace, simulating oxygen injection in the first few feet of the kiln to determine oxygen required to achieve magnetite oxidatio...
Main Author: | |
---|---|
Format: | Report |
Language: | English |
Published: |
University of Minnesota Duluth
2004
|
Subjects: | |
Online Access: | http://hdl.handle.net/11299/188316 |
Summary: | Final Report For Minnesota Department of Natural Resources Iron Ore Cooperative Research Performance of the Medusa modeling and simulation of the Keewatin Taconite Line 2 furnace, simulating oxygen injection in the first few feet of the kiln to determine oxygen required to achieve magnetite oxidation levels equivalent to ported kiln performance, greater than 95% complete at the kiln discharge point. University of Minnesota Duluth, Natural Resources Research Institute, 5013 Miller Trunk Highway, Duluth, MN 55811-1442; Coleraine Minerals Research Laboratory, One Gayley Avenue, Box 188, Coleraine, MN 55722 |
---|