The Coupling of Dynamics and Chemistry in the Antarctic Stratosphere

This thesis addresses the parameterisation of chemical and dynamical processes in the Antarctic stratosphere. Statistical models for the inter- and intra-annual variability in Antarctic stratospheric ozone depletion were developed based on theory and an understanding of the coupling of dynamics and...

Full description

Bibliographic Details
Main Author: Huck, Petra Ellen
Format: Other/Unknown Material
Language:English
Published: University of Canterbury. Physics and Astronomy 2007
Subjects:
Online Access:http://hdl.handle.net/10092/1410
https://doi.org/10.26021/8162
Description
Summary:This thesis addresses the parameterisation of chemical and dynamical processes in the Antarctic stratosphere. Statistical models for the inter- and intra-annual variability in Antarctic stratospheric ozone depletion were developed based on theory and an understanding of the coupling of dynamics and chemistry in the atmosphere. It was confirmed that the primary driver of the long-term trend in the severity of the Antarctic ozone hole is halogen loading in the stratosphere. The year-to-year variability in ozone mass deficit, a measure of the severity of Antarctic ozone depletion, could be described by a linear combination of South Pole temperatures and midlatitude wave activity. A time lag of two weeks between wave activity effects and ozone depletion indicates the predictive capability of meteorological parameters for seasonal projections of the severity of the Antarctic ozone hole. The statistical model describing the inter-annual variability in ozone mass deficit was regressed against observations from 1979 to 2004. The resulting regression coefficients were applied to South Pole temperature and wave activity fields from 28 chemistry-climate models. This analysis indicates a slight increase in the year-to-year variability in the severity of Antarctic ozone depletion. As a prelude to analysing the seasonal evolution of Antarctic ozone depletion, an improved ozone mass deficit measure was derived by replacing the constant 220 DU threshold with a seasonal varying pre-ozone hole background which leads to better capturing the true extent of the depleted ozone. Furthermore, it was shown that the new measure represents the chemical ozone loss within the Antarctic vortex provided that no mixing occurs through the vortex boundary. This new measure has many advantages over previous stratospheric ozone depletion indices. The conventional ozone mass deficit omits large amounts of depleted mass of ozone, and the onset of ozone depletion does not coincide with the timing of when sunlight first reaches areas of polar ...