Nära-nollenergibyggnader

Det nya EU-direktivet EPBD2, Energy Performance of Buildings Directive (recast), som antogs 2010, specificerar att alla nya byggnader ska vara så kallade nära-nollenergibyggnader år 2021. En nära-nollenergibyggnad definieras som en byggnad med mycket hög energiprestanda, som till mycket hög grad för...

Full description

Bibliographic Details
Main Author: Allard, Ingrid
Format: Bachelor Thesis
Language:Swedish
Published: Umeå universitet, Institutionen för tillämpad fysik och elektronik 2011
Subjects:
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-58946
Description
Summary:Det nya EU-direktivet EPBD2, Energy Performance of Buildings Directive (recast), som antogs 2010, specificerar att alla nya byggnader ska vara så kallade nära-nollenergibyggnader år 2021. En nära-nollenergibyggnad definieras som en byggnad med mycket hög energiprestanda, som till mycket hög grad förses med förnybar energi. Hur detta ska tolkas och var kravnivån ska sättas för energianvändningen är upp till varje land att besluta. I Sverige pågår just nu en debatt om detta och Energimyndigheten har fått i uppdrag att utforma en svensk strategi för att möta kravet om nära-nollenergibyggnader. Nära sammanlänkat med detta är också miljömålen om minskad klimatpåverkan till 2020 och 2050. För att sätta en rimlig kravnivå för energianvändning måste både ekonomiska-, tekniska och miljöaspekter tas hänsyn till. I denna rapport undersöks ett planerat bostadsområde i Västra Sörhaga, Alingsås, för att utvärdera hur det skulle kunna bebyggas för att nå upp till standarden för näranollenergibyggnader. En större undersökning görs också för att studera en rimlig kravnivå för nära-nollenergibyggnader i hela landet. Energiberäkningsprogrammet VIP-energy används för detta ändamål, fyra byggnader i olika storlekar simuleras. Var man sätter systemgränsen har stor inverkan på resultatet vid bedömningen av en byggnads energianvändning. EPBD2 fastställer att byggnadens energiprestanda ska prioriteras före tillförseln av förnybara energikällor. För att uppnå en byggnad med god energiprestanda krävs först en optimerad byggnadsprestanda (vilken innefattar de mest långlivade delarna av byggnaden, t.ex. klimatskalet), sedan ett effektivt energisystem och en effektiv energitillförsel. När detta är uppnått kan man sedan fokusera på att den tillförda energin i så hög grad som möjligt ska vara förnybar. Det är således viktigt att först optimera byggnadens prestanda, för att sedan väga in energitillförselsystem och energikälla varmed byggnaden också förses med så låg primärenergi och så mycket förnybar och miljövänlig energi som möjligt. Energimyndighetens strategi föreslår ett energikrav som mål för nära-nollenergibyggnader på halva dagens energikrav i Boverkets byggregler. Resultaten visar att det skulle innebära ganska höga krav för små byggnader längst upp i norr. Ett exempel på åtgärder som skulle innebära att denna nivå uppnås även för en villa i Kiruna är eliminering av köldbryggor, värmeväxling av ventilationsluften med 90 % verkningsgrad, fönster med u-värde på 0.7 W/m2K, dörrar med 0.6 W/m2K, täthet på 0.2 l/s,m2 och en fönsterandel på 10 %. Detta ligger i överkant med vad som är möjligt att uppnå med dagens teknik. Värmeväxlare med 90 % verkningsgrad finns idag, men eftersom värmeväxlare behöver avfrostas i kallt klimat, vilket sänker den verkliga verkningsgraden, kan det vara svårt att uppnå denna verkningsgrad praktiken i Kiruna. Med framtida teknikutveckling och större erfarenheter av lågenergibyggnationer är dock energimyndighetens förslag en rimlig standard för näranollenergibyggnader i hela landet. Det skulle dock vara fördelaktigt med en uppdelning av landet i fler klimatzoner, eller åtminstone en jämnare uppdelning, eftersom variationen i energianvändning för likadana byggnader idag är betydligt större i den nordligaste klimatzonen än i den sydligaste. I de södra delarna av Sverige skulle det vara möjligt att sätta passivhusstandarden som kravnivå för nära-nollenergibyggnader, men det rekommenderas inte i de norra delarna eftersom speciellt små byggnader i dagsläget är mycket svåra att bygga i passivhusstandard i kallt klimat. Att uppnå passivhusstandard för villor i den nordligaste delen av landet skulle kunna kräva en inomhustemperatur som inte överstiger 20°C och en täthet på 0. l/s,m2. Detta är inte rimligt, främst för att det enligt brukardata är vanligt med högre inomhustemperaturer i Sverige och för att en så hög täthet inte kan garanteras idag. Området i Västra Sörhaga, Alingsås, är däremot realistiskt att bygga i passivhusstandard eftersom det ligger i klimatzon III och det skulle då med största säkerhet också uppfylla standarden för näranollenergibyggnader. Om området byggdes i passivhusstandard skulle det resultera i en total specifik energianvändning i storleksordningen 50 kWh/m2,år, och en total energianvändning som motsvarar 45 % av energianvändningen för ett likadant område som uppfyller dagens energikrav i Boverkets byggregler. Kring 180 000 kWh/år skulle kunna tas från fjärrvärme. Boverkets förslag till revideringen av energikraven 2011 bedöms inte vara tillräckligt ambitiösa och gör det mycket svårt att uppnå miljömålen till 2020. Ytterligare studier behöver göras på den ekonomiska lönsamheten för lågenergibyggander, och för att kunna värdera den tillförda energin på ett enhetligt sätt behöver primärenergifaktorer tas fram. Dessa bör inkludera både effektivitet i framställningen, energiform och energislag. Energislagen bör i sin tur bedömas efter grad av förnybarhet, tillgång och lagringsmöjlighet. Lågenergibebyggelse kräver en stor omställning av den befintliga byggmarknaden och energistrukturen. För att hinna med detta till 2021 måste vi börja nu! The new EU directive EPBD2, Energy Performance of Buildings Directive (recast), adopted 2010, specifies that all new buildings must be so-called nearly-zero-energy-buildings by year 2021. A nearly-zero-energy-building is a building with very high energy performance, which is provided with renewable energy to a large extent. How this should be interpreted and where the requirement is to be placed on energy usage is up to each country to decide. There is currently a debate about this going on in Sweden, and the Swedish Energy Agency has been asked to design a strategy to meet the goals for nearly-zero-energy-buildings. The environmental goal for reducing the carbon footprint by 2020 and 2050 is also closely linked to this question. In order to set a reasonable level of requirement for energy use, both economic-, technical- and environmental aspects must be taken into account. This report studies a new building area in Västra Sörhaga, Alingsås, to find out how to build it in order to achieve the standard for nearly-zero-energy-buildings. A wider study is also made to find out where it is reasonable to set the level of requirements for energy use for nearly-zero-energybuildings throughout the country. The energy calculation software VIP-energy is used for simulating four buildings, off different sizes, and studying their energy consumption. Where the system boundary is placed has a big impact on the outcome of the measurement of a building's energy use. EPBD2 determines that the building's energy performance should be a priority, before the supply of renewable energy sources. In order to attain a building with a high energy performance, an optimized construction performance is first required, with an airtight and highly insulated building envelope and a ventilation system with heat recovery, and then an efficient energy system and an efficient energy supply should be ensured. When this is reached, the focus can then be put on making sure that the energy supplied is renewable to as large extent as possible. It is therefore important to optimize the building performance first and then take the energy supply system and energy sources into account, whereby the building also has a low primary energy use and is supplied with as much renewable and environmentally friendly energy as possible. The Swedish Energy Agency’s proposes an energy requirement of half the current energy requirements as a goal for nearly-zero-energy-buildings. One example of energy reducing measures that would result in achieving this standard for a cottage in Kiruna is: elimination of thermal bridges, heat exchange of the ventilation air with 90 % efficiency, windows with a heat transfer coefficient of 0.7 W/m2K and doors with 0.6 W/m2K, airtightness of 0.2 l/s,m2 and a window proportion of 10 %. This is a stretch of what is possible to achieve with today’s technology. Heat exchangers with an efficiency of 90 % exist today, but since they require defrosting in cold climate, which decreases the real efficiency, it could be difficult to achieve in Kiruna. However, with future technological developments and experiences of building low energy buildings, this would be a reasonable standard for nearly-zero-energy-buildings throughout the country. It would also be advantageous to divide the country into more climate zones, or at least divide them more equally. The variation in energy use for a building is today much larger in the most northern climate zone than in the southernmost. thermal bridges, heat exchange of the ventilation air with 90 % efficiency, windows with a heat transfer coefficient of 0.7 W/m2K and doors with 0.6 W/m2K, airtightness of 0.2 l/s,m2 and a window proportion of 10 %. This is a stretch of what is possible to achieve with today’s technology. Heat exchangers with an efficiency of 90 % exist today, but since they require defrosting in cold climate, which decreases the real efficiency, it could be difficult to achieve in Kiruna. However, with future technological developments and experiences of building low energy buildings, this would be a reasonable standard for nearly-zero-energy-buildings throughout the country. It would also be advantageous to divide the country into more climate zones, or at least divide them more equally. The variation in energy use for a building is today much larger in the most northern climate zone than in the southernmost. It would be possible to use the passive house standard requirements for nearly-zero-energybuildings in the southern parts of Sweden, but it is not recommended in the north. Especially small buildings are very difficult to build in the passive house standard in cold climates today. To reach passive house standard for a small building in the northern most part of Sweden could require an indoor temperature no higher than 20°C and an airtightness of 0.1 l/s,m2. This is not reasonable, mostly because it is common to have a higher indoor temperature in Sweden and because this very high air tightness cannot be guaranteed today. The area in Västra Sörhaga, Alingsås, is realistic to build with requirements of passive house standard because it is in climate zone III, and that would almost certainly also satisfy the standard for nearly-zero-energy-buildings. If the area was built in the passive house standard it would result in a total specific energy consumption of around 50 kWh/m2 per year, which is 45 % of the energy use for the same area built to meet today’s energy requirements. The national board of housing’s proposed energy requirements for the revision of the construction rules for 2011 are deemed not to be ambitious enough and makes it very difficult to achieve environmental objectives by 2020. Further studies need to be made on the economic viability of buildings with low energy use, and in order to assess the amount of energy in a uniform manner, primary energy factors need to be developed. These should include both efficiency in manufacturing, energy form and energy sources. Energy sources, in turn, should be judged by the degree of renewability, access and storage capacity. Construction of low-energy buildings requires a large change in the existing construction market and energy structure. We have to start now to achieve this by 2021!