Þeistareykir high-temperature geothermal field, North-East Iceland : estimation of reservoir conditions and evaluation of pressure interference between wells

Verkefnið er unnið í tengslum við Háskóla Íslands og Háskólann á Akureyri The Þeistareykir high-temperature geothermal field is located in northern Iceland. Seven deep boreholes have been drilled there since 2002. Temperature and pressure logs, measured during different operational stages of the wel...

Full description

Bibliographic Details
Main Author: Júlía Úlfdís Jóhannsson
Other Authors: Háskólinn á Akureyri
Format: Thesis
Language:English
Published: 2011
Subjects:
Online Access:http://hdl.handle.net/1946/7763
Description
Summary:Verkefnið er unnið í tengslum við Háskóla Íslands og Háskólann á Akureyri The Þeistareykir high-temperature geothermal field is located in northern Iceland. Seven deep boreholes have been drilled there since 2002. Temperature and pressure logs, measured during different operational stages of the wells, were analyzed to estimate formation temperature and initial pressure, as well as the possible location of feed zones in the wells. A new interpretation supports the hypothesis of an up-flow around well ÞG-1. It is possible that the up-flow does not spread as far to the west as was previously assumed. The highest temperatures measured in the new wells ÞG-5B and ÞG-6 were 300°C and 311°C, respectively. The discharge enthalpy for well ÞG-5B is higher than it is for well ÞG-5. Discharge from well ÞG-6 will possibly have similar characteristics as the discharge from wells ÞG-1 and ÞG-3, i.e. high temperature steam. Pressure recovery measurements in wells, which were shut in during the summer of 2008, have been evaluated using conventional well test analysis methods. The results obtained were compared with results of the interpretation of step-rate injection test data. Transmissivities evaluated in this work for wells ÞG-1 and ÞG-3 are lower than previous estimates while skin factor estimates have become more negative. Transmissivity, estimated by the analysis of injection test data for well ÞG-5B is close to the transmissivity estimated for well ÞG-5, or in the order of 7x10-8 m3/Pa-s; transmissivity, estimated for well ÞG-6 is close to the transmissivity for well ÞG-3, and in the order of 1.3 x10-8 m3/Pa-s. There are indications of interference between well ÞG-2 and wells ÞG-3, ÞG-5, ÞG-5B, and ÞG-6, as well as between ÞG-3 and ÞG-5. Well ÞG-1 has a limited communication with wells ÞG-2 and ÞG-3, however.