Indoor air quality in junior high schools in Reykjavík
Apart from the home, the school environment is probably the most important indoor environment for children and adolescents. Children spend as much as 80-90% of their indoor time either at school or at home. In Iceland, school, and thereby its environment, is compulsory for children between 6-16 year...
Main Author: | |
---|---|
Other Authors: | |
Format: | Thesis |
Language: | English |
Published: |
2009
|
Subjects: | |
Online Access: | http://hdl.handle.net/1946/3304 |
_version_ | 1821558079262556160 |
---|---|
author | Vanda Úlfrún Liv Hellsing 1980- |
author2 | Háskóli Íslands |
author_facet | Vanda Úlfrún Liv Hellsing 1980- |
author_sort | Vanda Úlfrún Liv Hellsing 1980- |
collection | Skemman (Iceland) |
description | Apart from the home, the school environment is probably the most important indoor environment for children and adolescents. Children spend as much as 80-90% of their indoor time either at school or at home. In Iceland, school, and thereby its environment, is compulsory for children between 6-16 years of age. Several recent studies have concluded that the environment at school may affect the pupils’ respiratory health and learning ability. The this study was to study the indoor air quality in junior high schools in Reykjavik with particular emphasis on levels of PM10 and ultra-fine particles(UFP). Measurements were performed in 74 classrooms in 15 public junior high schools in the Reykjavik city area. All the classrooms were occupied during measurements by children in 8th and 9th grade (13-15 years old) and their teachers. Levels of CO2, PM10, UFP, temperature and RH% were measured in each classroom. An environmental inspection was also performed in each classroom,where the fleece factor (m2/m3), shelf factor (m/m3), number of persons per room volume (pers/m3), personal outdoor air supply rate (L/s/person) and the air exchange rate (ac/hour) were measured and calculated. Levels of PM10 and UFP were measured immediately outside the 15 studied schools. A Kendall’s tau-b correlation analysis was used to study potential correlations within and/or between indoor climatic and environmental factors. The same method was used to study correlations within and/or between levels of indoor PM10 and UFP, and outdoor levels of PM10 and UFP. Results were compared with those from comparable school studies in Taiyuan, China and Uppsala, Sweden. The results indicate a need for improvement in the indoor climate in junior high schools in Reykjavik. Mean levels of CO2 in the classrooms were 1510 ppm, and significantly above the recommended max limit value of 1000 ppm. In approximately 87% of the schools mean CO2 levels lay above the recommended max limit. The mean level of PM10 in the classrooms was 40.4 µg/m3, ranging between 6.3-162 ... |
format | Thesis |
genre | Iceland Reykjavík Reykjavík |
genre_facet | Iceland Reykjavík Reykjavík |
geographic | Reykjavík |
geographic_facet | Reykjavík |
id | ftskemman:oai:skemman.is:1946/3304 |
institution | Open Polar |
language | English |
op_collection_id | ftskemman |
op_relation | http://hdl.handle.net/1946/3304 |
publishDate | 2009 |
record_format | openpolar |
spelling | ftskemman:oai:skemman.is:1946/3304 2025-01-16T22:41:12+00:00 Indoor air quality in junior high schools in Reykjavík Vanda Úlfrún Liv Hellsing 1980- Háskóli Íslands 2009-01-31T14:28:57Z application/pdf http://hdl.handle.net/1946/3304 en eng http://hdl.handle.net/1946/3304 Umhverfis- og auðlindafræði Loftgæði Loftmælingar Grunnskólar Inniloft Thesis Master's 2009 ftskemman 2022-12-11T06:56:32Z Apart from the home, the school environment is probably the most important indoor environment for children and adolescents. Children spend as much as 80-90% of their indoor time either at school or at home. In Iceland, school, and thereby its environment, is compulsory for children between 6-16 years of age. Several recent studies have concluded that the environment at school may affect the pupils’ respiratory health and learning ability. The this study was to study the indoor air quality in junior high schools in Reykjavik with particular emphasis on levels of PM10 and ultra-fine particles(UFP). Measurements were performed in 74 classrooms in 15 public junior high schools in the Reykjavik city area. All the classrooms were occupied during measurements by children in 8th and 9th grade (13-15 years old) and their teachers. Levels of CO2, PM10, UFP, temperature and RH% were measured in each classroom. An environmental inspection was also performed in each classroom,where the fleece factor (m2/m3), shelf factor (m/m3), number of persons per room volume (pers/m3), personal outdoor air supply rate (L/s/person) and the air exchange rate (ac/hour) were measured and calculated. Levels of PM10 and UFP were measured immediately outside the 15 studied schools. A Kendall’s tau-b correlation analysis was used to study potential correlations within and/or between indoor climatic and environmental factors. The same method was used to study correlations within and/or between levels of indoor PM10 and UFP, and outdoor levels of PM10 and UFP. Results were compared with those from comparable school studies in Taiyuan, China and Uppsala, Sweden. The results indicate a need for improvement in the indoor climate in junior high schools in Reykjavik. Mean levels of CO2 in the classrooms were 1510 ppm, and significantly above the recommended max limit value of 1000 ppm. In approximately 87% of the schools mean CO2 levels lay above the recommended max limit. The mean level of PM10 in the classrooms was 40.4 µg/m3, ranging between 6.3-162 ... Thesis Iceland Reykjavík Reykjavík Skemman (Iceland) Reykjavík |
spellingShingle | Umhverfis- og auðlindafræði Loftgæði Loftmælingar Grunnskólar Inniloft Vanda Úlfrún Liv Hellsing 1980- Indoor air quality in junior high schools in Reykjavík |
title | Indoor air quality in junior high schools in Reykjavík |
title_full | Indoor air quality in junior high schools in Reykjavík |
title_fullStr | Indoor air quality in junior high schools in Reykjavík |
title_full_unstemmed | Indoor air quality in junior high schools in Reykjavík |
title_short | Indoor air quality in junior high schools in Reykjavík |
title_sort | indoor air quality in junior high schools in reykjavík |
topic | Umhverfis- og auðlindafræði Loftgæði Loftmælingar Grunnskólar Inniloft |
topic_facet | Umhverfis- og auðlindafræði Loftgæði Loftmælingar Grunnskólar Inniloft |
url | http://hdl.handle.net/1946/3304 |