Environmental regulation of xylem sap flow and total conductance of Larix gmelinii (Rupr.) Rupr. trees in Eastern Siberia

Xylem sap flow and environmental variables were measured on seven consecutive midsummer days in a 130-year-old Larix gmelinii (Rupr.) Rupr. forest located 160 km south of Yakutsk in eastern Siberia, Russia (61° N, 128° E, 300 m asl). The site received 20 mm of rainfall during the 4 days before measu...

Full description

Bibliographic Details
Published in:Tree Physiology
Main Authors: Arneth, A., Kelliher, F., Bauer, G., Hollinger, D., Byers, J., Hunt, J., McSeveny, T., Ziegler, W., Vygodskaya, N., Milukova, I., Sogachev, A., Varlagin, A., Schulze, E.
Format: Article in Journal/Newspaper
Language:unknown
Published: 1996
Subjects:
Online Access:http://hdl.handle.net/21.11116/0000-0004-AC4B-7
http://hdl.handle.net/21.11116/0000-0004-AC4D-5
Description
Summary:Xylem sap flow and environmental variables were measured on seven consecutive midsummer days in a 130-year-old Larix gmelinii (Rupr.) Rupr. forest located 160 km south of Yakutsk in eastern Siberia, Russia (61° N, 128° E, 300 m asl). The site received 20 mm of rainfall during the 4 days before measurements, and soil samples indicated that the trees were well watered. The tree canopy was sparse with a one-sided leaf area index of 1.5 and a tree density of 1760 ha−1. On a clear day when air temperature ranged from 9 to 29 °C, and maximum air saturation deficit was 3.4 kPa, daily xylem sap flux (F) among 13 trees varied by an order of magnitude from 7 l day−1 for subcanopy trees (representing 55% of trees in the forest) to 67 l day−1 for emergent trees (representing 18% of trees in the forest). However, when based on xylem sap flux density (F′), calculated by dividing F by projected tree crown area (a surrogate for the occupied ground area), there was only a fourfold range in variability among the 13 trees, from 1.0 to 4.4 mm day−1. The calculation of F′ also eliminated systematic and large differences in F among emergent, canopy and subcanopy trees. Stand-level F′, estimated by combining half-hourly linear relationships between F and stem cross-sectional area with tree size distribution data, ranged between 1.8 ± 0.4 (standard deviation) and 2.3 ± 0.6 mm day−1. These stand-level F′ values are about 0.6–0.7 mm day−1 (30%) larger than daily tree canopy transpiration rates calculated from forest energy balance and understory evaporation measurements. Maximum total tree conductance for water vapor transfer (Gtmax, including canopy and aerodynamic conductances), calculated from the ratio of F′ and the above-canopy air saturation deficit (D) for the eight trees with continuous data sets, was 9.9 ± 2.8 mm s−1. This is equivalent to a leaf-scale maximum stomatal conductance (gsmax) of 6.1 mm s−1, when expressed on a one-sided leaf area basis, which is comparable to the published porometer data for Larix. Diurnal variation ...