Analysis of a Benchmark Building Installed with Tuned Mass Dampers under Wind and Earthquake Loads

Publisher's version (útgefin grein) This study presents analysis of a benchmark building installed with tuned mass dampers (TMDs) while subjected to wind and earthquake loads. Different TMD schemes are applied to reduce dynamic responses of the building under wind and earthquakes. The coupled e...

Full description

Bibliographic Details
Published in:Shock and Vibration
Main Authors: Elias, Said, Rupakhety, Rajesh, Olafsson, Stefan
Other Authors: Rannsóknarmiðstöð í jarðskjálftaverkfræði (HÍ), Earthquake Engineering Research Centre (UI), Verkfræði- og náttúruvísindasvið (HÍ), School of Engineering and Natural Sciences (UI), Háskóli Íslands, University of Iceland
Format: Article in Journal/Newspaper
Language:English
Published: Hindawi Limited 2019
Subjects:
Online Access:https://hdl.handle.net/20.500.11815/1879
https://doi.org/10.1155/2019/7091819
id ftopinvisindi:oai:opinvisindi.is:20.500.11815/1879
record_format openpolar
spelling ftopinvisindi:oai:opinvisindi.is:20.500.11815/1879 2023-05-15T16:50:51+02:00 Analysis of a Benchmark Building Installed with Tuned Mass Dampers under Wind and Earthquake Loads Elias, Said Rupakhety, Rajesh Olafsson, Stefan Rannsóknarmiðstöð í jarðskjálftaverkfræði (HÍ) Earthquake Engineering Research Centre (UI) Verkfræði- og náttúruvísindasvið (HÍ) School of Engineering and Natural Sciences (UI) Háskóli Íslands University of Iceland 2019-11-19 1-13 https://hdl.handle.net/20.500.11815/1879 https://doi.org/10.1155/2019/7091819 en eng Hindawi Limited Shock and Vibration;2019 https://www.hindawi.com/journals/sv/2019/7091819/ Elias, S., et al. (2019). "Analysis of a Benchmark Building Installed with Tuned Mass Dampers under Wind and Earthquake Loads." Shock and Vibration 2019: 7091819. 1070-9622 1875-9203 (eISSN) https://hdl.handle.net/20.500.11815/1879 Shock and Vibration doi:10.1155/2019/7091819 info:eu-repo/semantics/openAccess Earthquakes Buildings Tuned mass dampers Jarðskjálftar Byggingar info:eu-repo/semantics/article 2019 ftopinvisindi https://doi.org/20.500.11815/1879 https://doi.org/10.1155/2019/7091819 2022-11-18T06:51:57Z Publisher's version (útgefin grein) This study presents analysis of a benchmark building installed with tuned mass dampers (TMDs) while subjected to wind and earthquake loads. Different TMD schemes are applied to reduce dynamic responses of the building under wind and earthquakes. The coupled equations of motion are formulated and solved using numerical methods. The uncontrolled building (NC) and the controlled building are subjected to a set of 100 earthquake ground motions and wind forces. The effectiveness of using different multiple TMD (MTMD) schemes as opposed to single TMD (STMD) is presented. Optimal TMD parameters and their location are investigated. For a tall structure like the one studied here, TMDs are found to be more effective in controlling acceleration response than displacement, when subjected to wind forces. It is observed that MTMDs with equal stiffness in each of the TMDs (usually considered for wind response control), when optimized for a given structure, are effective in controlling acceleration response under both wind and earthquake forces. However, if the device is designed with equal mass in every floor, it is less effective in controlling wind-induced floor acceleration. Therefore, when it comes to multihazard response control, distributed TMDs with equal stiffnesses should be preferred over those with equal masses. The authors acknowledge the support from the University of Iceland Research Fund. Peer Reviewed Article in Journal/Newspaper Iceland Opin vísindi (Iceland) Shock and Vibration 2019 1 13
institution Open Polar
collection Opin vísindi (Iceland)
op_collection_id ftopinvisindi
language English
topic Earthquakes
Buildings
Tuned mass dampers
Jarðskjálftar
Byggingar
spellingShingle Earthquakes
Buildings
Tuned mass dampers
Jarðskjálftar
Byggingar
Elias, Said
Rupakhety, Rajesh
Olafsson, Stefan
Analysis of a Benchmark Building Installed with Tuned Mass Dampers under Wind and Earthquake Loads
topic_facet Earthquakes
Buildings
Tuned mass dampers
Jarðskjálftar
Byggingar
description Publisher's version (útgefin grein) This study presents analysis of a benchmark building installed with tuned mass dampers (TMDs) while subjected to wind and earthquake loads. Different TMD schemes are applied to reduce dynamic responses of the building under wind and earthquakes. The coupled equations of motion are formulated and solved using numerical methods. The uncontrolled building (NC) and the controlled building are subjected to a set of 100 earthquake ground motions and wind forces. The effectiveness of using different multiple TMD (MTMD) schemes as opposed to single TMD (STMD) is presented. Optimal TMD parameters and their location are investigated. For a tall structure like the one studied here, TMDs are found to be more effective in controlling acceleration response than displacement, when subjected to wind forces. It is observed that MTMDs with equal stiffness in each of the TMDs (usually considered for wind response control), when optimized for a given structure, are effective in controlling acceleration response under both wind and earthquake forces. However, if the device is designed with equal mass in every floor, it is less effective in controlling wind-induced floor acceleration. Therefore, when it comes to multihazard response control, distributed TMDs with equal stiffnesses should be preferred over those with equal masses. The authors acknowledge the support from the University of Iceland Research Fund. Peer Reviewed
author2 Rannsóknarmiðstöð í jarðskjálftaverkfræði (HÍ)
Earthquake Engineering Research Centre (UI)
Verkfræði- og náttúruvísindasvið (HÍ)
School of Engineering and Natural Sciences (UI)
Háskóli Íslands
University of Iceland
format Article in Journal/Newspaper
author Elias, Said
Rupakhety, Rajesh
Olafsson, Stefan
author_facet Elias, Said
Rupakhety, Rajesh
Olafsson, Stefan
author_sort Elias, Said
title Analysis of a Benchmark Building Installed with Tuned Mass Dampers under Wind and Earthquake Loads
title_short Analysis of a Benchmark Building Installed with Tuned Mass Dampers under Wind and Earthquake Loads
title_full Analysis of a Benchmark Building Installed with Tuned Mass Dampers under Wind and Earthquake Loads
title_fullStr Analysis of a Benchmark Building Installed with Tuned Mass Dampers under Wind and Earthquake Loads
title_full_unstemmed Analysis of a Benchmark Building Installed with Tuned Mass Dampers under Wind and Earthquake Loads
title_sort analysis of a benchmark building installed with tuned mass dampers under wind and earthquake loads
publisher Hindawi Limited
publishDate 2019
url https://hdl.handle.net/20.500.11815/1879
https://doi.org/10.1155/2019/7091819
genre Iceland
genre_facet Iceland
op_relation Shock and Vibration;2019
https://www.hindawi.com/journals/sv/2019/7091819/
Elias, S., et al. (2019). "Analysis of a Benchmark Building Installed with Tuned Mass Dampers under Wind and Earthquake Loads." Shock and Vibration 2019: 7091819.
1070-9622
1875-9203 (eISSN)
https://hdl.handle.net/20.500.11815/1879
Shock and Vibration
doi:10.1155/2019/7091819
op_rights info:eu-repo/semantics/openAccess
op_doi https://doi.org/20.500.11815/1879
https://doi.org/10.1155/2019/7091819
container_title Shock and Vibration
container_volume 2019
container_start_page 1
op_container_end_page 13
_version_ 1766040968569552896