PRECISE MEASUREMENTS OF DIELECTRIC ANISOTROPY IN ICE Ih AT 35GHz USING AN OPEN MICROWAVE RESONATOR
P(論文) Precise measurement of the dielectric anisotropy in ice Ih at 35GHz was carried out using an open microwave resonator (Fabry-Perot resonator). The purpose of the measurement was to obtain physical parameters necessary for analysis of the polarization state of the electromagnetic waves that pro...
Main Authors: | , , , , , , , |
---|---|
Language: | English |
Published: |
National Institute of Polar Research
1994
|
Subjects: | |
Online Access: | https://nipr.repo.nii.ac.jp/record/3858/files/KJ00000767966.pdf https://doi.org/10.15094/00003858 https://nipr.repo.nii.ac.jp/records/3858 |
_version_ | 1829314282010968064 |
---|---|
author | モリシマ, シゲノリ フジタ, シュウジ マツオカ, タケシ マエ, シンジ MORISHIMA, Shigenori FUJITA, Shuji MATSUOKA, Takeshi MAE, Shinji |
author_facet | モリシマ, シゲノリ フジタ, シュウジ マツオカ, タケシ マエ, シンジ MORISHIMA, Shigenori FUJITA, Shuji MATSUOKA, Takeshi MAE, Shinji |
author_sort | モリシマ, シゲノリ |
collection | National Institute of Polar Research Repository, Japan |
description | P(論文) Precise measurement of the dielectric anisotropy in ice Ih at 35GHz was carried out using an open microwave resonator (Fabry-Perot resonator). The purpose of the measurement was to obtain physical parameters necessary for analysis of the polarization state of the electromagnetic waves that propagate through ice masses. The open resonator method was used, because it is suitable for detecting the precise value of dielectric anisotropy, since we can detect both components, permittivity parallel to the c-axis (ε'_<//c>) and permittivity perpendicular to the c-axis (ε'_<⊥c>), at once from a single ice crystal without moving. The result of the measurement at -20℃ was as follows : ε_<//c> is 3.2016±0.0003 and ε'_<⊥c> is 3.1681±0.0003. Thus the dielectric anisotropy (Δε'=ε'_<//c>-ε'_<⊥c>) becomes 0.0335±0.0004. departmental bulletin paper |
genre | Polar meteorology and glaciology Proceedings of the NIPR Symposium on Polar Meteorology and Glaciology |
genre_facet | Polar meteorology and glaciology Proceedings of the NIPR Symposium on Polar Meteorology and Glaciology |
id | ftnipr:oai:nipr.repo.nii.ac.jp:00003858 |
institution | Open Polar |
language | English |
op_collection_id | ftnipr |
op_doi | https://doi.org/10.15094/00003858 |
op_relation | Proceedings of the NIPR Symposium on Polar Meteorology and Glaciology 8 201 AA10756213 https://nipr.repo.nii.ac.jp/record/3858/files/KJ00000767966.pdf https://doi.org/10.15094/00003858 https://nipr.repo.nii.ac.jp/records/3858 |
publishDate | 1994 |
publisher | National Institute of Polar Research |
record_format | openpolar |
spelling | ftnipr:oai:nipr.repo.nii.ac.jp:00003858 2025-04-13T14:25:53+00:00 PRECISE MEASUREMENTS OF DIELECTRIC ANISOTROPY IN ICE Ih AT 35GHz USING AN OPEN MICROWAVE RESONATOR モリシマ, シゲノリ フジタ, シュウジ マツオカ, タケシ マエ, シンジ MORISHIMA, Shigenori FUJITA, Shuji MATSUOKA, Takeshi MAE, Shinji 1994-11 application/pdf https://nipr.repo.nii.ac.jp/record/3858/files/KJ00000767966.pdf https://doi.org/10.15094/00003858 https://nipr.repo.nii.ac.jp/records/3858 eng eng National Institute of Polar Research Proceedings of the NIPR Symposium on Polar Meteorology and Glaciology 8 201 AA10756213 https://nipr.repo.nii.ac.jp/record/3858/files/KJ00000767966.pdf https://doi.org/10.15094/00003858 https://nipr.repo.nii.ac.jp/records/3858 1994 ftnipr https://doi.org/10.15094/00003858 2025-03-19T10:19:57Z P(論文) Precise measurement of the dielectric anisotropy in ice Ih at 35GHz was carried out using an open microwave resonator (Fabry-Perot resonator). The purpose of the measurement was to obtain physical parameters necessary for analysis of the polarization state of the electromagnetic waves that propagate through ice masses. The open resonator method was used, because it is suitable for detecting the precise value of dielectric anisotropy, since we can detect both components, permittivity parallel to the c-axis (ε'_<//c>) and permittivity perpendicular to the c-axis (ε'_<⊥c>), at once from a single ice crystal without moving. The result of the measurement at -20℃ was as follows : ε_<//c> is 3.2016±0.0003 and ε'_<⊥c> is 3.1681±0.0003. Thus the dielectric anisotropy (Δε'=ε'_<//c>-ε'_<⊥c>) becomes 0.0335±0.0004. departmental bulletin paper Other/Unknown Material Polar meteorology and glaciology Proceedings of the NIPR Symposium on Polar Meteorology and Glaciology National Institute of Polar Research Repository, Japan |
spellingShingle | モリシマ, シゲノリ フジタ, シュウジ マツオカ, タケシ マエ, シンジ MORISHIMA, Shigenori FUJITA, Shuji MATSUOKA, Takeshi MAE, Shinji PRECISE MEASUREMENTS OF DIELECTRIC ANISOTROPY IN ICE Ih AT 35GHz USING AN OPEN MICROWAVE RESONATOR |
title | PRECISE MEASUREMENTS OF DIELECTRIC ANISOTROPY IN ICE Ih AT 35GHz USING AN OPEN MICROWAVE RESONATOR |
title_full | PRECISE MEASUREMENTS OF DIELECTRIC ANISOTROPY IN ICE Ih AT 35GHz USING AN OPEN MICROWAVE RESONATOR |
title_fullStr | PRECISE MEASUREMENTS OF DIELECTRIC ANISOTROPY IN ICE Ih AT 35GHz USING AN OPEN MICROWAVE RESONATOR |
title_full_unstemmed | PRECISE MEASUREMENTS OF DIELECTRIC ANISOTROPY IN ICE Ih AT 35GHz USING AN OPEN MICROWAVE RESONATOR |
title_short | PRECISE MEASUREMENTS OF DIELECTRIC ANISOTROPY IN ICE Ih AT 35GHz USING AN OPEN MICROWAVE RESONATOR |
title_sort | precise measurements of dielectric anisotropy in ice ih at 35ghz using an open microwave resonator |
url | https://nipr.repo.nii.ac.jp/record/3858/files/KJ00000767966.pdf https://doi.org/10.15094/00003858 https://nipr.repo.nii.ac.jp/records/3858 |