Installation of the superconducting gravimeter CT(#043) at Syowa Station, Antarctica

P(論文) During the wintering period of the 44th Japanese Antarctic Research Expedition (JARE-44: February 2003 to January 2004), a new superconducting gravimeter CT(#043) with a cryocooler was installed and tested to replace the former TT70(#016) at Syowa Station, Antarctica. The CT(#043) has design s...

Full description

Bibliographic Details
Main Authors: Ikeda, Hiroshi, Doi, Koichiro, Fukuda, Yoichi, Tamura, Yoshiaki, Shibuya, Kazuo
Language:English
Published: National Institute of Polar Research 2005
Subjects:
Online Access:https://nipr.repo.nii.ac.jp/record/3149/files/KJ00003562990.pdf
https://doi.org/10.15094/00003149
https://nipr.repo.nii.ac.jp/records/3149
_version_ 1829309991645872128
author Ikeda, Hiroshi
Doi, Koichiro
Fukuda, Yoichi
Tamura, Yoshiaki
Shibuya, Kazuo
author_facet Ikeda, Hiroshi
Doi, Koichiro
Fukuda, Yoichi
Tamura, Yoshiaki
Shibuya, Kazuo
author_sort Ikeda, Hiroshi
collection National Institute of Polar Research Repository, Japan
description P(論文) During the wintering period of the 44th Japanese Antarctic Research Expedition (JARE-44: February 2003 to January 2004), a new superconducting gravimeter CT(#043) with a cryocooler was installed and tested to replace the former TT70(#016) at Syowa Station, Antarctica. The CT(#043) has design sensitivity of 1nGal (1×10^(-11)m/s^2) to study the Earth's dynamics in tidal and longer-period bands. A new type of diaphragm was used to effectively isolate the vibration from the refrigerator cold-head and to prevent solid air contamination from entering the Dewar. A real-time remote monitoring system including a Web camera for diagnostics from Japan has also been installed. departmental bulletin paper
genre Antarc*
Antarctic
Antarctica
Polar geoscience
genre_facet Antarc*
Antarctic
Antarctica
Polar geoscience
geographic Antarctic
Syowa Station
Dewar
geographic_facet Antarctic
Syowa Station
Dewar
id ftnipr:oai:nipr.repo.nii.ac.jp:00003149
institution Open Polar
language English
long_lat ENVELOPE(-21.158,-21.158,-80.534,-80.534)
op_collection_id ftnipr
op_doi https://doi.org/10.15094/00003149
op_relation Polar geoscience
18
49
57
AA1130866X
https://nipr.repo.nii.ac.jp/record/3149/files/KJ00003562990.pdf
https://doi.org/10.15094/00003149
https://nipr.repo.nii.ac.jp/records/3149
publishDate 2005
publisher National Institute of Polar Research
record_format openpolar
spelling ftnipr:oai:nipr.repo.nii.ac.jp:00003149 2025-04-13T14:08:05+00:00 Installation of the superconducting gravimeter CT(#043) at Syowa Station, Antarctica Ikeda, Hiroshi Doi, Koichiro Fukuda, Yoichi Tamura, Yoshiaki Shibuya, Kazuo 2005-10 application/pdf https://nipr.repo.nii.ac.jp/record/3149/files/KJ00003562990.pdf https://doi.org/10.15094/00003149 https://nipr.repo.nii.ac.jp/records/3149 eng eng National Institute of Polar Research Polar geoscience 18 49 57 AA1130866X https://nipr.repo.nii.ac.jp/record/3149/files/KJ00003562990.pdf https://doi.org/10.15094/00003149 https://nipr.repo.nii.ac.jp/records/3149 superconducting gravimeter GM refrigerator diaphragm monitoring system Syowa Station 2005 ftnipr https://doi.org/10.15094/00003149 2025-03-19T10:19:57Z P(論文) During the wintering period of the 44th Japanese Antarctic Research Expedition (JARE-44: February 2003 to January 2004), a new superconducting gravimeter CT(#043) with a cryocooler was installed and tested to replace the former TT70(#016) at Syowa Station, Antarctica. The CT(#043) has design sensitivity of 1nGal (1×10^(-11)m/s^2) to study the Earth's dynamics in tidal and longer-period bands. A new type of diaphragm was used to effectively isolate the vibration from the refrigerator cold-head and to prevent solid air contamination from entering the Dewar. A real-time remote monitoring system including a Web camera for diagnostics from Japan has also been installed. departmental bulletin paper Other/Unknown Material Antarc* Antarctic Antarctica Polar geoscience National Institute of Polar Research Repository, Japan Antarctic Syowa Station Dewar ENVELOPE(-21.158,-21.158,-80.534,-80.534)
spellingShingle superconducting gravimeter
GM refrigerator
diaphragm
monitoring system
Syowa Station
Ikeda, Hiroshi
Doi, Koichiro
Fukuda, Yoichi
Tamura, Yoshiaki
Shibuya, Kazuo
Installation of the superconducting gravimeter CT(#043) at Syowa Station, Antarctica
title Installation of the superconducting gravimeter CT(#043) at Syowa Station, Antarctica
title_full Installation of the superconducting gravimeter CT(#043) at Syowa Station, Antarctica
title_fullStr Installation of the superconducting gravimeter CT(#043) at Syowa Station, Antarctica
title_full_unstemmed Installation of the superconducting gravimeter CT(#043) at Syowa Station, Antarctica
title_short Installation of the superconducting gravimeter CT(#043) at Syowa Station, Antarctica
title_sort installation of the superconducting gravimeter ct(#043) at syowa station, antarctica
topic superconducting gravimeter
GM refrigerator
diaphragm
monitoring system
Syowa Station
topic_facet superconducting gravimeter
GM refrigerator
diaphragm
monitoring system
Syowa Station
url https://nipr.repo.nii.ac.jp/record/3149/files/KJ00003562990.pdf
https://doi.org/10.15094/00003149
https://nipr.repo.nii.ac.jp/records/3149