Summary: | NASA's Goddard Space Flight Center/Wallops Flight Facility conducted a series of 52 balloon-borne measurements of vertical ozone profiles over the National Science Foundation (NSF) research facility at Palmer Station, Antarctica (64 deg 46 S, 64 deg 3 W) between August 9 and October 24, 1987. High resolution measurements were made from ground level to an average of 10 mb. While much variation was seen in the profile amounts of ozone, it is clear that a progressive depletion of ozone occurred during the measurement period, with maximum depletion taking place in the 17 to 19 km altitude region. Ozone partial pressures dropped by about 95 percent in this region. Shown here are plotted time dependences of ozone amounts observed at 17 km and at arbitrarily selected altitudes below (13 km) and above (24 km) the region of maximum depletion. Ozone partial pressure at 17 km is about 150nb in early August, and has decreased to less than 10nb in the minimums in October. The loss rate is of the order of 1.5 percent/day. In summary, a progressive depletion in stratospheric ozone over Palmer Station was observed from August to October, 1987. Maximum depletion occurred in the 17 to 19 km range, and amounted to 95 percent. Total ozone overburden decreased by up to 50 percent during the same period.
|