Evaluation of AIRS, MODIS, and HIRS 11 micron brightness temperature difference changes from 2002 through 2006

In an effort to validate the accuracy and stability of AIRS data at low scene temperatures (200-250 K range), we evaluated brightness temperatures at 11 microns with Aqua MODIS band 31 and HIRS/3 channel 8 for Antarctic granules between September 2002 and May 2006. We found excellent agreement with...

Full description

Bibliographic Details
Main Authors: Broberg, Steven E., Aumann, Hartmut H., Gregorich, David T., Xiong, X.
Format: Report
Language:English
Published: Pasadena, CA : Jet Propulsion Laboratory, National Aeronautics and Space Administration, 2006. 2006
Subjects:
Online Access:http://hdl.handle.net/2014/39856
Description
Summary:In an effort to validate the accuracy and stability of AIRS data at low scene temperatures (200-250 K range), we evaluated brightness temperatures at 11 microns with Aqua MODIS band 31 and HIRS/3 channel 8 for Antarctic granules between September 2002 and May 2006. We found excellent agreement with MODIS (at the 0.2 K level) over the full emperature range in data from early in the Aqua mission. However, in more recent data, starting in April 2005, we found a scene temperature dependence in MODIS-AIRS brightness temperature differences, with a discrepancy of 1- 1.5 K at 200 K. The comparison between AIRS and HIRS/3 (channel 8) on NOAA 16 for the same time period yields excellent agreement. The cause and time dependence of the disagreement with MODIS is under evaluation, but the change was coincident with a change in the MODIS production software from collection 4 to 5. NASA/JPL