Implanted Nanosensors in Marine Organisms for Physiological Biologging: Design, Feasibility, and Species Variability

© 2018 American Chemical Society. In recent decades, biologists have sought to tag animals with various sensors to study aspects of their behavior otherwise inaccessible from controlled laboratory experiments. Despite this, chemical information, both environmental and physiological, remains challeng...

Full description

Bibliographic Details
Main Authors: Lee, Michael A, Nguyen, Freddy T, Scott, Kathleen, Chan, Nathan YL, Bakh, Naveed Ali, Jones, Kelvin K, Pham, Crystal, Garcia-Salinas, Pablo, Garcia-Parraga, Daniel, Fahlman, Andreas, Marco, Vicente, Koman, Volodymyr B, Oliver, Ronald J, Hopkins, Lloyd W, Rubio, Consuelo, Wilson, Rory P, Meekan, Mark G, Duarte, Carlos M, Strano, Michael S
Other Authors: Massachusetts Institute of Technology. Department of Chemical Engineering, Massachusetts Institute of Technology. Division of Comparative Medicine
Format: Article in Journal/Newspaper
Language:English
Published: American Chemical Society (ACS) 2019
Subjects:
Online Access:https://hdl.handle.net/1721.1/134899
Description
Summary:© 2018 American Chemical Society. In recent decades, biologists have sought to tag animals with various sensors to study aspects of their behavior otherwise inaccessible from controlled laboratory experiments. Despite this, chemical information, both environmental and physiological, remains challenging to collect despite its tremendous potential to elucidate a wide range of animal behaviors. In this work, we explore the design, feasibility, and data collection constraints of implantable, near-infrared fluorescent nanosensors based on DNA-wrapped single-wall carbon nanotubes (SWNT) embedded within a biocompatible poly(ethylene glycol) diacrylate (PEGDA) hydrogel. These sensors are enabled by Corona Phase Molecular Recognition (CoPhMoRe) to provide selective chemical detection for marine organism biologging. Riboflavin, a key nutrient in oxidative phosphorylation, is utilized as a model analyte in in vitro and ex vivo tissue measurements. Nine species of bony fish, sharks, eels, and turtles were utilized on site at Oceanogràfic in Valencia, Spain to investigate sensor design parameters, including implantation depth, sensor imaging and detection limits, fluence, and stability, as well as acute and long-term biocompatibility. Hydrogels were implanted subcutaneously and imaged using a customized, field-portable Raspberry Pi camera system. Hydrogels could be detected up to depths of 7 mm in the skin and muscle tissue of deceased teleost fish (Sparus aurata and Stenotomus chrysops) and a deceased catshark (Galeus melastomus). The effects of tissue heterogeneity on hydrogel delivery and fluorescence visibility were explored, with darker tissues masking hydrogel fluorescence. Hydrogels were implanted into a living eastern river cooter (Pseudemys concinna), a European eel (Anguilla anguilla), and a second species of catshark (Scyliorhinus stellaris). The animals displayed no observable changes in movement and feeding patterns. Imaging by high-resolution ultrasound indicated no changes in tissue structure in the eel and ...