Fatigue strength of cable couplers in prestressed concrete beams
Fatigue tests have been carried out on ten prestressed concrete beams. Six of the beams were furnished with a cable coupler in the mid-span and four beams had no cable coupler. The uncoupled beams could in some cases sustain 9 times as many load cycles as the coupled beams. Some probable causes to t...
Main Authors: | , , |
---|---|
Format: | Article in Journal/Newspaper |
Language: | English |
Published: |
Luleå tekniska universitet, Byggkonstruktion och -produktion
1982
|
Subjects: | |
Online Access: | http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-14125 |
Summary: | Fatigue tests have been carried out on ten prestressed concrete beams. Six of the beams were furnished with a cable coupler in the mid-span and four beams had no cable coupler. The uncoupled beams could in some cases sustain 9 times as many load cycles as the coupled beams. Some probable causes to the coupled beams lower fatigue strength are discussed in the paper. Godkänd; 1982; Bibliografisk uppgift: Även publicerad som Teknisk rapport / Högskolan i Luleå, 1983:12; 20061109 (ysko) |
---|