Retinal oximetry with a scanning laser ophthalmoscope.
To access publisher's full text version of this article click on the hyperlink at the bottom of the page The purpose of the study was to assess if a scanning laser ophthalmoscope (SLO), Optomap 200Tx, could be used for measurements of hemoglobin oxygen saturation in retinal blood vessels. Optom...
Published in: | Investigative Opthalmology & Visual Science |
---|---|
Main Authors: | , , , , , |
Other Authors: | |
Format: | Article in Journal/Newspaper |
Language: | English |
Published: |
Assoc Research Vision Ophthalmolo Inc.
2014
|
Subjects: | |
Online Access: | http://hdl.handle.net/2336/325485 https://doi.org/10.1167/iovs.13-13255 |
_version_ | 1821548415738183680 |
---|---|
author | Kristjansdottir, Jona Valgerdur Hardarson, Sveinn Hakon Halldorsson, Gisli Hreinn Karlsson, Robert A Eliasdottir, Thorunn S Stefánsson, Einar |
author2 | Landspitali Univ Hosp, Dept Ophthalmol, Reykjavik, Iceland, Univ Iceland, IS-101 Reykjavik, Iceland, Oxymap Ehf, Reykjavik, Iceland |
author_facet | Kristjansdottir, Jona Valgerdur Hardarson, Sveinn Hakon Halldorsson, Gisli Hreinn Karlsson, Robert A Eliasdottir, Thorunn S Stefánsson, Einar |
author_sort | Kristjansdottir, Jona Valgerdur |
collection | Hirsla - Landspítali University Hospital research archive |
container_issue | 5 |
container_start_page | 3120 |
container_title | Investigative Opthalmology & Visual Science |
container_volume | 55 |
description | To access publisher's full text version of this article click on the hyperlink at the bottom of the page The purpose of the study was to assess if a scanning laser ophthalmoscope (SLO), Optomap 200Tx, could be used for measurements of hemoglobin oxygen saturation in retinal blood vessels. Optomap 200Tx uses two lasers for image acquisition, 532 and 633 nm. Retinal images of healthy individuals and patients with retinal vein occlusion were analyzed with modified Oxymap Analyzer software, which tracks retinal vessels and calculates relative hemoglobin oxygen saturation. Oxygen saturation in healthy individuals was measured as 92% ± 13% for arterioles and 57% ± 12% for venules (mean ± SD, n = 11, P = 0.0001). Standard deviation for repeated measurements of the same eye was 3.5% for arterioles and 4.4% for venules. In patients with confirmed venular hypoxia, central retinal vein occlusion (CRVO) or hemivein occlusion, the average venular oxygen saturation was measured as 23% ± 3% in the affected eyes and 59% ± 3% in the fellow eyes (n = 4, P = 0.0009). Technically, it is possible to derive information on retinal oxygen saturation from an SLO with a 2-wavelength oximetry algorithm. The system produced both sensitive and repeatable results. The remaining challenges include decreasing variability between vessels of the same eye and variability between individuals. Given the advantages that SLO imaging has over conventional fundus camera optics in retinal oximetry, further development of SLO oximetry may provide the optimal approach to retinal oximetry. Optos plc. Dunfermline (Scotland, United Kingdom) Icelandic Center for Research (Rannis, Iceland) Icelandic Prevention of Blindness Fund (Reykjavik, Iceland) Landspitali-University Hospital Research Fund (Reykjavik, Iceland) University of Iceland Research Fund (Reykjavik, Iceland) Helga Jonsdottir and Sigurlioi Kristjansson Memorial Fund (Reykjavik, Iceland) |
format | Article in Journal/Newspaper |
genre | Iceland |
genre_facet | Iceland |
id | ftlandspitaliuni:oai:www.hirsla.lsh.is:2336/325485 |
institution | Open Polar |
language | English |
op_collection_id | ftlandspitaliuni |
op_doi | https://doi.org/10.1167/iovs.13-13255 |
op_relation | http://dx.doi.org/10.1167/iovs.13-13255 http://www.iovs.org/content/55/5/3120.full.pdf Invest. Ophthalmol. Vis. Sci. 2014, 55 (5):3120-6 1552-5783 24736055 doi:10.1167/iovs.13-13255 http://hdl.handle.net/2336/325485 Investigative ophthalmology & visual science |
op_rights | Archived with thanks to Investigative ophthalmology & visual science Landspitali Access - LSH-aðgangur |
publishDate | 2014 |
publisher | Assoc Research Vision Ophthalmolo Inc. |
record_format | openpolar |
spelling | ftlandspitaliuni:oai:www.hirsla.lsh.is:2336/325485 2025-01-16T22:31:37+00:00 Retinal oximetry with a scanning laser ophthalmoscope. Kristjansdottir, Jona Valgerdur Hardarson, Sveinn Hakon Halldorsson, Gisli Hreinn Karlsson, Robert A Eliasdottir, Thorunn S Stefánsson, Einar Landspitali Univ Hosp, Dept Ophthalmol, Reykjavik, Iceland, Univ Iceland, IS-101 Reykjavik, Iceland, Oxymap Ehf, Reykjavik, Iceland 2014 http://hdl.handle.net/2336/325485 https://doi.org/10.1167/iovs.13-13255 en eng Assoc Research Vision Ophthalmolo Inc. http://dx.doi.org/10.1167/iovs.13-13255 http://www.iovs.org/content/55/5/3120.full.pdf Invest. Ophthalmol. Vis. Sci. 2014, 55 (5):3120-6 1552-5783 24736055 doi:10.1167/iovs.13-13255 http://hdl.handle.net/2336/325485 Investigative ophthalmology & visual science Archived with thanks to Investigative ophthalmology & visual science Landspitali Access - LSH-aðgangur Augnsjúkdómar Sjónhimna Adult Analysis of Variance Female Humans Male Microscopy Confocal/instrumentation* Middle Aged Ophthalmoscopes Ophthalmoscopy/methods* Oximetry/methods* Oxygen/blood* Reproducibility of Results Retinal Vein Occlusion/physiopathology* Retinal Vessels/physiology* Sensitivity and Specificity Article 2014 ftlandspitaliuni https://doi.org/10.1167/iovs.13-13255 2022-05-29T08:21:59Z To access publisher's full text version of this article click on the hyperlink at the bottom of the page The purpose of the study was to assess if a scanning laser ophthalmoscope (SLO), Optomap 200Tx, could be used for measurements of hemoglobin oxygen saturation in retinal blood vessels. Optomap 200Tx uses two lasers for image acquisition, 532 and 633 nm. Retinal images of healthy individuals and patients with retinal vein occlusion were analyzed with modified Oxymap Analyzer software, which tracks retinal vessels and calculates relative hemoglobin oxygen saturation. Oxygen saturation in healthy individuals was measured as 92% ± 13% for arterioles and 57% ± 12% for venules (mean ± SD, n = 11, P = 0.0001). Standard deviation for repeated measurements of the same eye was 3.5% for arterioles and 4.4% for venules. In patients with confirmed venular hypoxia, central retinal vein occlusion (CRVO) or hemivein occlusion, the average venular oxygen saturation was measured as 23% ± 3% in the affected eyes and 59% ± 3% in the fellow eyes (n = 4, P = 0.0009). Technically, it is possible to derive information on retinal oxygen saturation from an SLO with a 2-wavelength oximetry algorithm. The system produced both sensitive and repeatable results. The remaining challenges include decreasing variability between vessels of the same eye and variability between individuals. Given the advantages that SLO imaging has over conventional fundus camera optics in retinal oximetry, further development of SLO oximetry may provide the optimal approach to retinal oximetry. Optos plc. Dunfermline (Scotland, United Kingdom) Icelandic Center for Research (Rannis, Iceland) Icelandic Prevention of Blindness Fund (Reykjavik, Iceland) Landspitali-University Hospital Research Fund (Reykjavik, Iceland) University of Iceland Research Fund (Reykjavik, Iceland) Helga Jonsdottir and Sigurlioi Kristjansson Memorial Fund (Reykjavik, Iceland) Article in Journal/Newspaper Iceland Hirsla - Landspítali University Hospital research archive Investigative Opthalmology & Visual Science 55 5 3120 |
spellingShingle | Augnsjúkdómar Sjónhimna Adult Analysis of Variance Female Humans Male Microscopy Confocal/instrumentation* Middle Aged Ophthalmoscopes Ophthalmoscopy/methods* Oximetry/methods* Oxygen/blood* Reproducibility of Results Retinal Vein Occlusion/physiopathology* Retinal Vessels/physiology* Sensitivity and Specificity Kristjansdottir, Jona Valgerdur Hardarson, Sveinn Hakon Halldorsson, Gisli Hreinn Karlsson, Robert A Eliasdottir, Thorunn S Stefánsson, Einar Retinal oximetry with a scanning laser ophthalmoscope. |
title | Retinal oximetry with a scanning laser ophthalmoscope. |
title_full | Retinal oximetry with a scanning laser ophthalmoscope. |
title_fullStr | Retinal oximetry with a scanning laser ophthalmoscope. |
title_full_unstemmed | Retinal oximetry with a scanning laser ophthalmoscope. |
title_short | Retinal oximetry with a scanning laser ophthalmoscope. |
title_sort | retinal oximetry with a scanning laser ophthalmoscope. |
topic | Augnsjúkdómar Sjónhimna Adult Analysis of Variance Female Humans Male Microscopy Confocal/instrumentation* Middle Aged Ophthalmoscopes Ophthalmoscopy/methods* Oximetry/methods* Oxygen/blood* Reproducibility of Results Retinal Vein Occlusion/physiopathology* Retinal Vessels/physiology* Sensitivity and Specificity |
topic_facet | Augnsjúkdómar Sjónhimna Adult Analysis of Variance Female Humans Male Microscopy Confocal/instrumentation* Middle Aged Ophthalmoscopes Ophthalmoscopy/methods* Oximetry/methods* Oxygen/blood* Reproducibility of Results Retinal Vein Occlusion/physiopathology* Retinal Vessels/physiology* Sensitivity and Specificity |
url | http://hdl.handle.net/2336/325485 https://doi.org/10.1167/iovs.13-13255 |