050 Automated analysis of atrial delayed enhancement cardiac MRI correlates with voltage, AF recurrence post-ablation, and high stroke risk

Introduction Visualisation of atrial scar using delayed-enhanced MRI (DE-MRI) may reveal causes for atrial fibrillation recurrence following ablation. To develop an objective method for delineating ablation-scar we compared DE-MRI before and after Cryoballoon ablation on the basis that a predictable...

Full description

Bibliographic Details
Published in:Heart
Main Authors: Malcolme-Lawes, L, Juli, C, Karim, R, Bai, W, Quest, R, Lim, P B, Jamil-Copley, S, Kojodjojo, P, Ariff, B, Davies, D W, Rueckert, D, Hunter, R, Boubertakh, R, Petersen, S, Schilling, R, Kanagaratnam, P, Peters, N S
Format: Text
Language:English
Published: BMJ Publishing Group Ltd 2012
Subjects:
Online Access:http://heart.bmj.com/cgi/content/short/98/Suppl_1/A30-ax
https://doi.org/10.1136/heartjnl-2012-301877b.50
Description
Summary:Introduction Visualisation of atrial scar using delayed-enhanced MRI (DE-MRI) may reveal causes for atrial fibrillation recurrence following ablation. To develop an objective method for delineating ablation-scar we compared DE-MRI before and after Cryoballoon ablation on the basis that a predictable antral lesion set would be created. The method was subsequently used in patients undergoing radiofrequency or cryoballoon ablation. Endocardial voltage was measured and compared with corresponding enhancement levels on DE-MRI. Pre and post ablation enhancement was then compared with clinical outcome and risk factors for stroke. Methods Pre-ablation DE-MRI was performed in 50 patients from two centres, undergoing pulmonary vein isolation; 25 with Arctic Front cryoballoon and 25 with conventional circumferential pulmonary vein ablation. Post-ablation DE-MRI was performed at 3&emsp14;months. 10 patients at the first procedure and 12 patients returning for a redo procedure underwent endocardial voltage mapping with registration to MRA segmentation for comparison with the DE-MRI. The free-breathing late gadolinium enhanced sequence was also registered to the MRA segmentation and surface intensities were normalised using mean intensity of the blood pool (BlP). Normalised intensity levels were projected onto LA surface as multiples of SD above BlP mean. Results Ostial and LA intensity were similar in pre ablation scans and greater in the ostia in post ablation scans (p=0.48 and p<0.001 respectively). Bipolar voltage measurements were compared for each intensity level. No significant differences were noted between SD 0 and 1, however significant difference were noted between SD 1 and 2 (1.41±0.03 vs 1.26±0.04&emsp14;mV p<0.001), SD 2 and 3, (1.26±0.04 vs 0.90 ±0.05&emsp14;mV p<0.001), SD 3 and 4 (0.90±0.05 vs 0.63±0.04 mV p<0.001) and SD 4 and 5, (0.63±0.04 vs 0.45±0.05 p=0.004). No significant differences were found between intensities > SD 5. Intensity > SD 3 was identified as low voltage ...