Extending the Useful Life of Dye-2 to 1986. Part . 1979 Findings and Final Recommendations
A major construction effort is needed at Dew Line Ice Cap Station DYE-2 to extend its useful life to 1986. That work should be done as soon as possible because the truss enclosure is deteriorating rapidly. Although a 210-ft sideways move as was accomplished at DYE-3 in 1977 is technically feasible,...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Text |
Language: | English |
Published: |
1980
|
Subjects: | |
Online Access: | http://www.dtic.mil/docs/citations/ADA084278 http://oai.dtic.mil/oai/oai?&verb=getRecord&metadataPrefix=html&identifier=ADA084278 |
id |
ftdtic:ADA084278 |
---|---|
record_format |
openpolar |
spelling |
ftdtic:ADA084278 2023-05-15T16:03:04+02:00 Extending the Useful Life of Dye-2 to 1986. Part . 1979 Findings and Final Recommendations Tobiasson, Wayne Tilton, Philip COLD REGIONS RESEARCH AND ENGINEERING LAB HANOVER NH 1980-04 text/html http://www.dtic.mil/docs/citations/ADA084278 http://oai.dtic.mil/oai/oai?&verb=getRecord&metadataPrefix=html&identifier=ADA084278 en eng http://www.dtic.mil/docs/citations/ADA084278 Approved for public release; distribution is unlimited. DTIC AND NTIS Snow Ice and Permafrost Structural Engineering and Building Technology *ICE CAPS *RADAR STATIONS *STRUCTURAL ANALYSIS ACCUMULATION BACKFILLS CONSTRUCTION COSTS DETERIORATION DISPLACEMENT FUEL TANKS GREENLAND ICE LIFE EXPECTANCY(SERVICE LIFE) REHABILITATION SEWAGE DISPOSAL STRESSES STRUCTURAL COMPONENTS SUBSURFACE TRUSSES DEW LINE DYE-2 STATION Text 1980 ftdtic 2016-02-24T12:18:41Z A major construction effort is needed at Dew Line Ice Cap Station DYE-2 to extend its useful life to 1986. That work should be done as soon as possible because the truss enclosure is deteriorating rapidly. Although a 210-ft sideways move as was accomplished at DYE-3 in 1977 is technically feasible, the alternative of backfilling the truss enclosure with ice is expected to cost about $2.7 million less. Unless there is a strong possibility that DYE-2 will be needed for many years beyond 1986, the ice backfill alternative is recommended. See also Part 1, ADA074733. Text Dye 3 Dye-3 Greenland Ice Ice cap permafrost Defense Technical Information Center: DTIC Technical Reports database Greenland |
institution |
Open Polar |
collection |
Defense Technical Information Center: DTIC Technical Reports database |
op_collection_id |
ftdtic |
language |
English |
topic |
Snow Ice and Permafrost Structural Engineering and Building Technology *ICE CAPS *RADAR STATIONS *STRUCTURAL ANALYSIS ACCUMULATION BACKFILLS CONSTRUCTION COSTS DETERIORATION DISPLACEMENT FUEL TANKS GREENLAND ICE LIFE EXPECTANCY(SERVICE LIFE) REHABILITATION SEWAGE DISPOSAL STRESSES STRUCTURAL COMPONENTS SUBSURFACE TRUSSES DEW LINE DYE-2 STATION |
spellingShingle |
Snow Ice and Permafrost Structural Engineering and Building Technology *ICE CAPS *RADAR STATIONS *STRUCTURAL ANALYSIS ACCUMULATION BACKFILLS CONSTRUCTION COSTS DETERIORATION DISPLACEMENT FUEL TANKS GREENLAND ICE LIFE EXPECTANCY(SERVICE LIFE) REHABILITATION SEWAGE DISPOSAL STRESSES STRUCTURAL COMPONENTS SUBSURFACE TRUSSES DEW LINE DYE-2 STATION Tobiasson, Wayne Tilton, Philip Extending the Useful Life of Dye-2 to 1986. Part . 1979 Findings and Final Recommendations |
topic_facet |
Snow Ice and Permafrost Structural Engineering and Building Technology *ICE CAPS *RADAR STATIONS *STRUCTURAL ANALYSIS ACCUMULATION BACKFILLS CONSTRUCTION COSTS DETERIORATION DISPLACEMENT FUEL TANKS GREENLAND ICE LIFE EXPECTANCY(SERVICE LIFE) REHABILITATION SEWAGE DISPOSAL STRESSES STRUCTURAL COMPONENTS SUBSURFACE TRUSSES DEW LINE DYE-2 STATION |
description |
A major construction effort is needed at Dew Line Ice Cap Station DYE-2 to extend its useful life to 1986. That work should be done as soon as possible because the truss enclosure is deteriorating rapidly. Although a 210-ft sideways move as was accomplished at DYE-3 in 1977 is technically feasible, the alternative of backfilling the truss enclosure with ice is expected to cost about $2.7 million less. Unless there is a strong possibility that DYE-2 will be needed for many years beyond 1986, the ice backfill alternative is recommended. See also Part 1, ADA074733. |
author2 |
COLD REGIONS RESEARCH AND ENGINEERING LAB HANOVER NH |
format |
Text |
author |
Tobiasson, Wayne Tilton, Philip |
author_facet |
Tobiasson, Wayne Tilton, Philip |
author_sort |
Tobiasson, Wayne |
title |
Extending the Useful Life of Dye-2 to 1986. Part . 1979 Findings and Final Recommendations |
title_short |
Extending the Useful Life of Dye-2 to 1986. Part . 1979 Findings and Final Recommendations |
title_full |
Extending the Useful Life of Dye-2 to 1986. Part . 1979 Findings and Final Recommendations |
title_fullStr |
Extending the Useful Life of Dye-2 to 1986. Part . 1979 Findings and Final Recommendations |
title_full_unstemmed |
Extending the Useful Life of Dye-2 to 1986. Part . 1979 Findings and Final Recommendations |
title_sort |
extending the useful life of dye-2 to 1986. part . 1979 findings and final recommendations |
publishDate |
1980 |
url |
http://www.dtic.mil/docs/citations/ADA084278 http://oai.dtic.mil/oai/oai?&verb=getRecord&metadataPrefix=html&identifier=ADA084278 |
geographic |
Greenland |
geographic_facet |
Greenland |
genre |
Dye 3 Dye-3 Greenland Ice Ice cap permafrost |
genre_facet |
Dye 3 Dye-3 Greenland Ice Ice cap permafrost |
op_source |
DTIC AND NTIS |
op_relation |
http://www.dtic.mil/docs/citations/ADA084278 |
op_rights |
Approved for public release; distribution is unlimited. |
_version_ |
1766398713973964800 |