EVALUATION OF DELCO-REMY STARTER RELAY FOR M60 SERIES TANKS

Tests were conducted to determine the suitability of the Delco-Remy starter relay for use in M60series tanks. The test item is an electrical relay in the engine starting circuit which energizes the starter motor and causes the starter drive gear to mesh with the gear train and crank the engine. It w...

Full description

Bibliographic Details
Other Authors: ARMY ARMOR BOARD FORT KNOX KY
Format: Text
Language:English
Published: 1962
Subjects:
Online Access:http://www.dtic.mil/docs/citations/AD0283597
http://oai.dtic.mil/oai/oai?&verb=getRecord&metadataPrefix=html&identifier=AD0283597
Description
Summary:Tests were conducted to determine the suitability of the Delco-Remy starter relay for use in M60series tanks. The test item is an electrical relay in the engine starting circuit which energizes the starter motor and causes the starter drive gear to mesh with the gear train and crank the engine. It was concluded that: (a) the starter relay is suitable for use in M60 and M60A1 tanks under temperate climate conditions, and (b) the starter relay should be subjected to test under arctic conditions. (Author)