Sustained Attention and Types of Dynamics of Cardiovascular Reactivity during a Short-Term, Human Whole-Body Exposure to Cold Air

Background: Despite global warming and the improvement of personal protective equipment against unfavorable climatic factors, cold remains an important environmental challenge for humans. The aim of the work was to reveal the peculiarities of the dynamics of cardiovascular parameters in humans with...

Full description

Bibliographic Details
Main Authors: Olga V. Krivonogova, Elena V. Krivonogova, Liliya V. Poskotinova
Format: Article in Journal/Newspaper
Language:English
Published: International Medical Research and Development Corporation 2020
Subjects:
R
Online Access:https://doaj.org/article/da31e9f2951f4b6b9f5fa5c15f254307
Description
Summary:Background: Despite global warming and the improvement of personal protective equipment against unfavorable climatic factors, cold remains an important environmental challenge for humans. The aim of the work was to reveal the peculiarities of the dynamics of cardiovascular parameters in humans with short-term, whole-body exposure to cold air, depending on the parameters of voluntary attention. Methods and Results: The study involved 28 healthy male volunteers aged between18 and 21 years, born and living in Arkhangelsk. Testing to assess sustained attention parameters using the Toulouse-Pierón Attention Test with the measurement of the index of accuracy (C, units) (the ability to voluntary concentration) and processing speed (V, units), had been previously performed. Subsequent stages of the study included recording the studied parameters before (Stage 1), during 10-minute exposure to the cold air (Stage 2), and 5 minutes after cold exposure (Stage 3). The registration of indicators in Stages 1 and 3 was carried out indoors at an air temperature of +20 °C. The registration of indicators in Stage 2 was carried out in a cold chamber at -20 °C. Determining the body temperature in the ear canal (Tear, °C) and on the skin of the dorsum of the right hand (Tskin, °C) was performed using a B.Well WF-1000 medical electronic infrared thermometer. Parameters of blood pressure (SBP and DBP) and heart rate variability (HRV) were evaluated. As a result of cluster analysis, 2 groups were identified: Group 1 (n=14) and Group 2 (n=14). In Group 2, the index V was significantly lower than in Group 1(P=0.02). In Group I, Tskin in Stage 1 was significantly higher than in Group 2 (P=0.03). In Stage 2, Tskin decreased in both groups, but lower Tskin values (P=0.001) were recorded in Group 2 than in Group I. In Stage 2, there was a statistically significant increase in SBP in Group 2 (P=0.01). In Group 1, initial SDNN and all HRV spectral indices were significantly higher than in Group 2. In Stage 2, there was a significant increase in ...