Leishmaniasis direct agglutination test: using pictorials as training materials to reduce inter-reader variability and improve accuracy.

BACKGROUND: The Direct Agglutination Test (DAT) has a high diagnostic accuracy and remains, in some geographical areas, part of the diagnostic algorithm for Visceral Leishmaniasis (VL). However, subjective interpretation of results introduces potential for inter-reader variation. We report an assess...

Full description

Bibliographic Details
Published in:PLoS Neglected Tropical Diseases
Main Authors: Emily R Adams, Diane Jacquet, Gerard Schoone, Kamlesh Gidwani, Marleen Boelaert, Jane Cunningham
Format: Article in Journal/Newspaper
Language:English
Published: Public Library of Science (PLoS) 2012
Subjects:
Online Access:https://doi.org/10.1371/journal.pntd.0001946
https://doaj.org/article/c86926a5b5084f6c83b9ebb811c2f198
Description
Summary:BACKGROUND: The Direct Agglutination Test (DAT) has a high diagnostic accuracy and remains, in some geographical areas, part of the diagnostic algorithm for Visceral Leishmaniasis (VL). However, subjective interpretation of results introduces potential for inter-reader variation. We report an assessment of inter-laboratory agreement and propose a pictorial-based approach to standardize reading of the DAT. METHODOLOGY: In preparation for a comparative evaluation of immunochromatographic diagnostics for VL, a proficiency panel of 15 well-characterized sera, DAT-antigen from a single batch and common protocol was sent to nine laboratories in Latin-America, East-Africa and Asia. Agreement (i.e., equal titre or within 1 titer) with the reading by the reference laboratory was computed. Due to significant inter-laboratory disagreement on-site refresher training was provided to all technicians performing DAT. Photos of training plates were made, and end-titres agreed upon by experienced users of DAT within the Visceral-Leishmaniasis Laboratory-Network (VL-LN). RESULTS: Pre-training, concordance in DAT results with reference laboratories was only 50%, although agreement on negative sera was high (94%). After refresher training concordance increased to 84%; agreement on negative controls increased to 98%. Variance in readings significantly decreased after training from 3.3 titres to an average of 1.0 titre (two-sample Wilcoxon rank-sum (Mann-Whitney) test (z = -3,624 and p = 0.0003)). CONCLUSION: The most probable explanation for disagreement was subjective endpoint reading. Using pictorials as training materials may be a useful tool to reduce disparity in results and promote more standardized reading of DAT, without compromising diagnostic sensitivity.