Interpretation of microscopic agglutination test for leptospirosis diagnosis and seroprevalence

Determination of antibody titer by microscopic agglutination test (MAT) has been used as a tool for leptospirosis diagnosis. Four fold or greater rise in antibody titers between acute and convalescent sera suggests recent Leptospira infection. In addition, results obtained by MAT have been used to p...

Full description

Bibliographic Details
Published in:Asian Pacific Journal of Tropical Biomedicine
Main Authors: Chintana Chirathaworn, Rajada Inwattana, Yong Poovorawan, Duangjai Suwancharoen
Format: Article in Journal/Newspaper
Language:English
Published: Wolters Kluwer Medknow Publications 2014
Subjects:
Online Access:https://doi.org/10.12980/APJTB.4.2014C580
https://doaj.org/article/9dc33b8d3e354018a31c10071a15f92f
Description
Summary:Determination of antibody titer by microscopic agglutination test (MAT) has been used as a tool for leptospirosis diagnosis. Four fold or greater rise in antibody titers between acute and convalescent sera suggests recent Leptospira infection. In addition, results obtained by MAT have been used to predict infecting serovars. However, cross reactivity among various Leptospira serovars have been reported when patient sera were tested with a battery of Leptospira serovars. This study demonstrates cross-reactivity among several Leptospira serovars when MAT was performed on leptospirosis sera. The data support a role of MAT as a tool for diagnosis. However, for information on infecting serovars, Leptospira isolation and molecular identification should be performed.