Interaction between a Cyclically Heated Building and the Ground, for Selected Locations in Europe

The aim of the study was to verify the impact of the location of a cyclically heated building on its energy needs and interaction with the environment. The model building was a large-scale broiler house located in southern Poland. In the examined facility, year-round measurements of selected paramet...

Full description

Bibliographic Details
Published in:Energies
Main Authors: Grzegorz Nawalany, Paweł Sokołowski
Format: Article in Journal/Newspaper
Language:English
Published: MDPI AG 2022
Subjects:
T
Online Access:https://doi.org/10.3390/en15207493
https://doaj.org/article/8cad61412cff4b33ae681c1e4ba75892
id ftdoajarticles:oai:doaj.org/article:8cad61412cff4b33ae681c1e4ba75892
record_format openpolar
spelling ftdoajarticles:oai:doaj.org/article:8cad61412cff4b33ae681c1e4ba75892 2023-05-15T17:04:20+02:00 Interaction between a Cyclically Heated Building and the Ground, for Selected Locations in Europe Grzegorz Nawalany Paweł Sokołowski 2022-10-01T00:00:00Z https://doi.org/10.3390/en15207493 https://doaj.org/article/8cad61412cff4b33ae681c1e4ba75892 EN eng MDPI AG https://www.mdpi.com/1996-1073/15/20/7493 https://doaj.org/toc/1996-1073 doi:10.3390/en15207493 1996-1073 https://doaj.org/article/8cad61412cff4b33ae681c1e4ba75892 Energies, Vol 15, Iss 7493, p 7493 (2022) numerical analysis model validation thermal humidity simulation heat exchange with the ground thermal interaction Technology T article 2022 ftdoajarticles https://doi.org/10.3390/en15207493 2022-12-30T23:08:21Z The aim of the study was to verify the impact of the location of a cyclically heated building on its energy needs and interaction with the environment. The model building was a large-scale broiler house located in southern Poland. In the examined facility, year-round measurements of selected parameters of the internal and external microclimate were carried out. The tests also covered the temperature of the soil in three measurement columns. The obtained measurement results were used for further computer analyses. A geometric model of the building was made and a calculation model specification was introduced, supported by specialized software for the physics of WUFI ® plus structures. The numerical analysis included validation. The validation results were assessed on the basis of the Coefficient of Determination method (R2) and the Goodness of Fit (GOF) method. Due to the lack of normality of the data distribution, a Rang-Spearman correlation analysis was carried out, which showed a very strong data correlation (0.94). The analysis of the R2 coefficient of determination confirmed the high reliability of the model (83%). In the case of the GOF method, a compliance value of 87% was obtained. Differentiated locations were adopted for further analysis, while maintaining the structure of the examined building in reality. Six European locations were selected: Kraków (Poland), Málaga (Spain), Brest (France), Visby (Sweden), Umea (Sweden), and Kiruna (Sweden). The analysis included three variants, in which the length of the technological break was adopted accordingly. A technological break between production cycles was assumed, the three variants of which lasted 3, 7, and 14 days. The analysis of the obtained results showed that the external microclimate significantly determines the energy interaction between the building and the ground. The length of the technological break is very important in a climate dominated by low temperatures (Northern Scandinavia). The south-western part of Europe allows the technological break ... Article in Journal/Newspaper Kiruna Directory of Open Access Journals: DOAJ Articles Kiruna Energies 15 20 7493
institution Open Polar
collection Directory of Open Access Journals: DOAJ Articles
op_collection_id ftdoajarticles
language English
topic numerical analysis
model validation
thermal humidity simulation
heat exchange with the ground
thermal interaction
Technology
T
spellingShingle numerical analysis
model validation
thermal humidity simulation
heat exchange with the ground
thermal interaction
Technology
T
Grzegorz Nawalany
Paweł Sokołowski
Interaction between a Cyclically Heated Building and the Ground, for Selected Locations in Europe
topic_facet numerical analysis
model validation
thermal humidity simulation
heat exchange with the ground
thermal interaction
Technology
T
description The aim of the study was to verify the impact of the location of a cyclically heated building on its energy needs and interaction with the environment. The model building was a large-scale broiler house located in southern Poland. In the examined facility, year-round measurements of selected parameters of the internal and external microclimate were carried out. The tests also covered the temperature of the soil in three measurement columns. The obtained measurement results were used for further computer analyses. A geometric model of the building was made and a calculation model specification was introduced, supported by specialized software for the physics of WUFI ® plus structures. The numerical analysis included validation. The validation results were assessed on the basis of the Coefficient of Determination method (R2) and the Goodness of Fit (GOF) method. Due to the lack of normality of the data distribution, a Rang-Spearman correlation analysis was carried out, which showed a very strong data correlation (0.94). The analysis of the R2 coefficient of determination confirmed the high reliability of the model (83%). In the case of the GOF method, a compliance value of 87% was obtained. Differentiated locations were adopted for further analysis, while maintaining the structure of the examined building in reality. Six European locations were selected: Kraków (Poland), Málaga (Spain), Brest (France), Visby (Sweden), Umea (Sweden), and Kiruna (Sweden). The analysis included three variants, in which the length of the technological break was adopted accordingly. A technological break between production cycles was assumed, the three variants of which lasted 3, 7, and 14 days. The analysis of the obtained results showed that the external microclimate significantly determines the energy interaction between the building and the ground. The length of the technological break is very important in a climate dominated by low temperatures (Northern Scandinavia). The south-western part of Europe allows the technological break ...
format Article in Journal/Newspaper
author Grzegorz Nawalany
Paweł Sokołowski
author_facet Grzegorz Nawalany
Paweł Sokołowski
author_sort Grzegorz Nawalany
title Interaction between a Cyclically Heated Building and the Ground, for Selected Locations in Europe
title_short Interaction between a Cyclically Heated Building and the Ground, for Selected Locations in Europe
title_full Interaction between a Cyclically Heated Building and the Ground, for Selected Locations in Europe
title_fullStr Interaction between a Cyclically Heated Building and the Ground, for Selected Locations in Europe
title_full_unstemmed Interaction between a Cyclically Heated Building and the Ground, for Selected Locations in Europe
title_sort interaction between a cyclically heated building and the ground, for selected locations in europe
publisher MDPI AG
publishDate 2022
url https://doi.org/10.3390/en15207493
https://doaj.org/article/8cad61412cff4b33ae681c1e4ba75892
geographic Kiruna
geographic_facet Kiruna
genre Kiruna
genre_facet Kiruna
op_source Energies, Vol 15, Iss 7493, p 7493 (2022)
op_relation https://www.mdpi.com/1996-1073/15/20/7493
https://doaj.org/toc/1996-1073
doi:10.3390/en15207493
1996-1073
https://doaj.org/article/8cad61412cff4b33ae681c1e4ba75892
op_doi https://doi.org/10.3390/en15207493
container_title Energies
container_volume 15
container_issue 20
container_start_page 7493
_version_ 1766058404931960832