A high-throughput and multiplex microsphere immunoassay based on non-structural protein 1 can discriminate three flavivirus infections.

The explosive spread of Zika virus (ZIKV) and associated complications in flavivirus-endemic regions underscore the need for sensitive and specific serodiagnostic tests to distinguish ZIKV, dengue virus (DENV) and other flavivirus infections. Compared with traditional envelope protein-based assays,...

Full description

Bibliographic Details
Published in:PLOS Neglected Tropical Diseases
Main Authors: Jasmine Tyson, Wen-Yang Tsai, Jih-Jin Tsai, Ludvig Mässgård, Susan L Stramer, Axel T Lehrer, Vivek R Nerurkar, Wei-Kung Wang
Format: Article in Journal/Newspaper
Language:English
Published: Public Library of Science (PLoS) 2019
Subjects:
Online Access:https://doi.org/10.1371/journal.pntd.0007649
https://doaj.org/article/87c4b23bb8d94f3ebbfea0fd5a063363
Description
Summary:The explosive spread of Zika virus (ZIKV) and associated complications in flavivirus-endemic regions underscore the need for sensitive and specific serodiagnostic tests to distinguish ZIKV, dengue virus (DENV) and other flavivirus infections. Compared with traditional envelope protein-based assays, several nonstructural protein 1 (NS1)-based assays showed improved specificity, however, none can detect and discriminate three flaviviruses in a single assay. Moreover, secondary DENV infection and ZIKV infection with previous DENV infection, both common in endemic regions, cannot be discriminated. In this study, we developed a high-throughput and multiplex IgG microsphere immunoassay (MIA) using the NS1 proteins of DENV1-DENV4, ZIKV and West Nile virus (WNV) to test samples from reverse-transcription-polymerase-chain reaction-confirmed cases, including primary DENV1, DENV2, DENV3, WNV and ZIKV infections, secondary DENV infection, and ZIKV infection with previous DENV infection. Combination of four DENV NS1 IgG MIAs revealed a sensitivity of 94.3% and specificity of 97.2% to detect DENV infection. The ZIKV and WNV NS1 IgG MIAs had a sensitivity/specificity of 100%/87.9% and 86.1%/78.4%, respectively. A positive correlation was found between the readouts of enzyme-linked immunosorbent assay and MIA for different NS1 tested. Based on the ratio of relative median fluorescence intensity of ZIKV NS1 to DENV1 NS1, the IgG MIA can distinguish ZIKV infection with previous DENV infection and secondary DENV infection with a sensitivity of 88.9-90.0% and specificity of 91.7-100.0%. The multiplex and high-throughput assay could be applied to serodiagnosis and serosurveillance of DENV, ZIKV and WNV infections in endemic regions.