Low quality of routine microscopy for malaria at different levels of the health system in Dar es Salaam

Abstract Background Laboratory capacity to confirm malaria cases in Tanzania is low and presumptive treatment of malaria is being practiced widely. In malaria endemic areas WHO now recommends systematic laboratory testing when suspecting malaria. Currently, the use of Rapid Diagnostic Tests (RDTs) i...

Full description

Bibliographic Details
Published in:Malaria Journal
Main Authors: Mtasiwa Deo, D'Acremont Valerie, Kahama-Maro Judith, Genton Blaise, Lengeler Christian
Format: Article in Journal/Newspaper
Language:English
Published: BMC 2011
Subjects:
Online Access:https://doi.org/10.1186/1475-2875-10-332
https://doaj.org/article/67c3651fee6a443b966c7340136d5ff8
Description
Summary:Abstract Background Laboratory capacity to confirm malaria cases in Tanzania is low and presumptive treatment of malaria is being practiced widely. In malaria endemic areas WHO now recommends systematic laboratory testing when suspecting malaria. Currently, the use of Rapid Diagnostic Tests (RDTs) is recommended for the diagnosis of malaria in lower level peripheral facilities, but not in health centres and hospitals. In this study, the following parameters were evaluated: (1) the quality of routine microscopy, and (2) the effects of RDT implementation on the positivity rate of malaria test results at three levels of the health system in Dar es Salaam, Tanzania. Methods During a baseline cross-sectional survey, routine blood slides were randomly picked from 12 urban public health facilities in Dar es Salaam, Tanzania. Sensitivity and specificity of routine slides were assessed against expert microscopy. In March 2007, following training of health workers, RDTs were introduced in nine public health facilities (three hospitals, three health centres and three dispensaries) in a near-to-programmatic way, while three control health facilities continued using microscopy. The monthly malaria positivity rates (PR) recorded in health statistics registers were collected before (routine microscopy) and after (routine RDTs) the intervention in all facilities. Results At baseline, 53% of blood slides were reported as positive by the routine laboratories, whereas only 2% were positive by expert microscopy. Sensitivity of routine microscopy was 71.4% and specificity was 47.3%. Positive and negative predictive values were 2.8% and 98.7%, respectively. Median parasitaemia was only three parasites per 200 white blood cells (WBC) by routine microscopy compared to 1226 parasites per 200 WBC by expert microscopy. Before RDT implementation, the mean test positivity rates using routine microscopy were 43% in hospitals, 62% in health centres and 58% in dispensaries. After RDT implementation, mean positivity rates using routine RDTs ...