Reliability of point-of-care circulating cathodic antigen assay for diagnosing schistosomiasis mansoni in urine samples from an endemic area of Brazil after one year of storage at -20 degrees Celsius

ABSTRACT Background The World Health Organization recommends reliable point-of-care (POC) diagnostic testing to eliminate schistosomiasis. Lateral flow immunoassay that detects schistosome circulating cathodic antigen (CCA) in urine to establish prevalence thresholds for intervention in endemic area...

Full description

Bibliographic Details
Published in:Revista da Sociedade Brasileira de Medicina Tropical
Main Authors: Tereza Cristina Favre, Lilian Christina Nóbrega Holsback Beck, Fernando Schemelzer Moraes Bezerra, Carlos Graeff-Teixeira, Paulo Marcos Zech Coelho, Martin Johannes Enk, Naftale Katz, Ricardo Riccio Oliveira, Mitermayer Galvão dos Reis, Otávio Sarmento Pieri
Format: Article in Journal/Newspaper
Language:English
Published: Sociedade Brasileira de Medicina Tropical (SBMT) 2022
Subjects:
Online Access:https://doi.org/10.1590/0037-8682-0389-2021
https://doaj.org/article/616ce79418ee4059946ff03522451a55
Description
Summary:ABSTRACT Background The World Health Organization recommends reliable point-of-care (POC) diagnostic testing to eliminate schistosomiasis. Lateral flow immunoassay that detects schistosome circulating cathodic antigen (CCA) in urine to establish prevalence thresholds for intervention in endemic areas is recommended. Stored urine may be useful if surveying at-risk populations is delayed or interrupted by unforeseen circumstances, such as the current COVID-19 pandemic. This study evaluated the manufacturer’s claim that Schistosoma mansoni infection can be reliably diagnosed in urine samples stored at -20°C for one year. Methods Two-hundred-forty-two subjects from an endemic site in Brazil provided one urine sample each for testing with URINE CCA (SCHISTO) ECO TESTE® (POC-ECO) and one stool sample each for testing with Kato-Katz (KK) and Helmintex® (HTX) as a robust reference standard for infection status. At least 2 ml of urine from each participant was stored at -20°C; after one year, 76 samples were randomly selected for POC-ECO retesting. Results: The POC-ECO agreement between freshly collected and stored urine was inadequate considering trace results as positive (Cohen’s kappa coefficient κ = 0.08) and negative (κ = 0.36). POC-ECO accuracy was not significantly greater than that of routine KK (54%; 95% confidence interval: 42.1%-65.5%). Conclusions The precision and accuracy of POC-ECO have to be optimized in both freshly collected and stored urine before it can be recommended for use in control programs in Brazil.