Pilot assessment of the sensitivity of the malaria thin film

Abstract Background Malaria microscopy remains the reference standard for malaria diagnosis in clinical trials (drug and vaccine), new diagnostic evaluation, as well as in clinical care in much of the world today. It is known that microscopy is an imperfect gold standard, and that very low false pos...

Full description

Bibliographic Details
Published in:Malaria Journal
Main Authors: Mtalib Ramadan, McEvoy Peter, Ogutu Bernhards, Remich Shon, O'Meara Wendy, Ohrt Colin, Odera James
Format: Article in Journal/Newspaper
Language:English
Published: BMC 2008
Subjects:
Online Access:https://doi.org/10.1186/1475-2875-7-22
https://doaj.org/article/4721a14aa12146edb6ed1d403c2676d6
Description
Summary:Abstract Background Malaria microscopy remains the reference standard for malaria diagnosis in clinical trials (drug and vaccine), new diagnostic evaluation, as well as in clinical care in much of the world today. It is known that microscopy is an imperfect gold standard, and that very low false positive rates can dramatically lower protective efficacy estimates in malaria prevention trials. Although new methods are now available, including malaria rapid diagnostic tests and PCR, neither is as yet validated in the clinical trial setting and both have limitations. Surprisingly, the sensitivity of thin smears is not well established and thin smears are not commonly used in the developing world. Methods Malaria thick and thin films were collected in the lowlands of Western Kenya. All had density determined by four readings with two methods, as well as species identified. Thirty-six with low density parasitaemia had the thin smear read by five independent microscopists, two were expert and three were qualified. Microscopists read the entire thin film. For the first 10 parasites seen, they reported the species, appearance, time, field number, and red blood cells in the field. Total parasites, total fields, and total time to examine the smear were also recorded. Results Median parasitaemia was 201 parasites/μl, mean 1,090 ± 2,195, range 6–11,124 parasites/μl for the 36 smears evaluated. The data revealed a density dependent increase in sensitivity, with 100% sensitivity achieved at >200 parasites/μl for experts and >500 parasites/μl for qualified readers. Thin film readings confirmed parasitaemia 74% of the time by experts, and 65% of the time for qualified microscopists. The 95 th percentile for time to detect parasitaemia was 15 minutes for experts, 17 minutes for qualified microscopists. This decreased to 4–10 minutes for experts at densities of > 200 parasites/μl. Additionally, substantial discordance for species identification was observed. Conclusion The thin film is sensitive enough to be a useful tool ...