Evaluation of the performance of a multiplex reverse transcription polymerase chain reaction kit as a potential diagnostic and surveillance kit for rotavirus in Kenya

Abstract Background Diarrhea is a serious concern worldwide, especially in developing countries. Rotavirus is implicated in approximately 400,000 infant deaths annually. It is highly contagious elevating the risk of outbreaks especially in enclosed settings such as daycare centers, hospitals, and bo...

Full description

Bibliographic Details
Published in:Tropical Diseases, Travel Medicine and Vaccines
Main Authors: Cliff Odhiambo Philip, Margaret Koech, Nancy Kipkemoi, Ronald Kirera, Janet Ndonye, Abigael Ombogo, Mary Kirui, Erick Kipkirui, Brook Danboise, Christine Hulseberg, Stacey Bateman, Alexander Flynn, Brett Swierczewski, Esther Magiri, Elizabeth Odundo
Format: Article in Journal/Newspaper
Language:English
Published: BMC 2019
Subjects:
EIA
PCR
Eia
Online Access:https://doi.org/10.1186/s40794-019-0087-7
https://doaj.org/article/166f543bc9f44f3ca1877d46db54712f
Description
Summary:Abstract Background Diarrhea is a serious concern worldwide, especially in developing countries. Rotavirus is implicated in approximately 400,000 infant deaths annually. It is highly contagious elevating the risk of outbreaks especially in enclosed settings such as daycare centers, hospitals, and boarding schools. Reliable testing methods are critical for early detection of infections, better clinical management, pathogen surveillance and evaluation of interventions such as vaccines. Enzyme immunoassays have proved to be reliable and practical in most settings; however, newer multiplex reverse transcription polymerase assays have been introduced in the Kenya market but have not been evaluated locally. Methods Stool samples collected from an ongoing Surveillance of Enteric Pathogens Causing diarrheal illness in Kenya (EPS) study were used to compare an established enzyme immunoassay, Premier™ Rotaclone® (Meridian Bioscience, Cincinnati, Ohio, U.S.A.), that can only detect group A rotavirus against a novel multiplex reverse transcription polymerase chain reaction kit, Seeplex® Diarrhea-V ACE Detection (Seegene, Seoul, Republic of Korea), that can detect rotavirus, astrovirus, adenovirus, and norovirus genogroups I and II. Detection frequency, sensitivity, specificity, turnaround time, and cost were compared to determine the suitability of each assay for clinical work in austere settings versus public health work in well-funded institutes in Kenya. Results The Premier™ Rotaclone® kit had a detection frequency of 11.2%, sensitivity of 77.8%, specificity of 100%, turnaround time of 93 min and an average cost per sample of 13.33 United States dollars (USD). The Seeplex® Diarrhea-V ACE Detection kit had a detection frequency of 16.0%, sensitivity of 100%, specificity of 98.1%, turnaround time of 359 min and an average cost per samples 32.74 United States dollars respectively. The detection frequency sensitivity and specificity of the Seeplex® Diarrhea-V ACE Detection kit mentioned above are for rotavirus only. ...