Field validity and feasibility of four techniques for the detection of Trichuris in simians: a model for monitoring drug efficacy in public health?

BACKGROUND: Soil-transmitted helminths, such as Trichuris trichiura, are of major concern in public health. Current efforts to control these helminth infections involve periodic mass treatment in endemic areas. Since these large-scale interventions are likely to intensify, monitoring the drug effica...

Full description

Bibliographic Details
Published in:PLoS Neglected Tropical Diseases
Main Authors: Bruno Levecke, Nathalie De Wilde, Els Vandenhoute, Jozef Vercruysse
Format: Article in Journal/Newspaper
Language:English
Published: Public Library of Science (PLoS) 2009
Subjects:
Online Access:https://doi.org/10.1371/journal.pntd.0000366
https://doaj.org/article/0f859ab8837d4f228f339142f4333a7b
Description
Summary:BACKGROUND: Soil-transmitted helminths, such as Trichuris trichiura, are of major concern in public health. Current efforts to control these helminth infections involve periodic mass treatment in endemic areas. Since these large-scale interventions are likely to intensify, monitoring the drug efficacy will become indispensible. However, studies comparing detection techniques based on sensitivity, fecal egg counts (FEC), feasibility for mass diagnosis and drug efficacy estimates are scarce. METHODOLOGY/PRINCIPAL FINDINGS: In the present study, the ether-based concentration, the Parasep Solvent Free (SF), the McMaster and the FLOTAC techniques were compared based on both validity and feasibility for the detection of Trichuris eggs in 100 fecal samples of nonhuman primates. In addition, the drug efficacy estimates of quantitative techniques was examined using a statistical simulation. Trichuris eggs were found in 47% of the samples. FLOTAC was the most sensitive technique (100%), followed by the Parasep SF (83.0% [95% confidence interval (CI): 82.4-83.6%]) and the ether-based concentration technique (76.6% [95% CI: 75.8-77.3%]). McMaster was the least sensitive (61.7% [95% CI: 60.7-62.6%]) and failed to detect low FEC. The quantitative comparison revealed a positive correlation between the four techniques (Rs = 0.85-0.93; p<0.0001). However, the ether-based concentration technique and the Parasep SF detected significantly fewer eggs than both the McMaster and the FLOTAC (p<0.0083). Overall, the McMaster was the most feasible technique (3.9 min/sample for preparing, reading and cleaning of the apparatus), followed by the ether-based concentration technique (7.7 min/sample) and the FLOTAC (9.8 min/sample). Parasep SF was the least feasible (17.7 min/sample). The simulation revealed that the sensitivity is less important for monitoring drug efficacy and that both FLOTAC and McMaster were reliable estimators. CONCLUSIONS/SIGNIFICANCE: The results of this study demonstrated that McMaster is a promising technique ...