An Analysis of the Thermal Regime and Energy Balance of a Subarctic Hydroelectric Reservoir Using Direct Measurements of Surface and Lateral Exchanges ...

These data were used for the paper entitled "An Analysis of the Thermal Regime and Energy Balance of a Subarctic Hydroelectric Reservoir Using Direct Measurements of Surface and Lateral Exchanges " and submitted to Hydrological Processes on May 2023. Tables has the following variables : be...

Full description

Bibliographic Details
Main Author: PIERRE, Adrien
Format: Article in Journal/Newspaper
Language:unknown
Published: Zenodo 2023
Subjects:
Online Access:https://dx.doi.org/10.5281/zenodo.7883779
https://zenodo.org/record/7883779
Description
Summary:These data were used for the paper entitled "An Analysis of the Thermal Regime and Energy Balance of a Subarctic Hydroelectric Reservoir Using Direct Measurements of Surface and Lateral Exchanges " and submitted to Hydrological Processes on May 2023. Tables has the following variables : bernard.temp.2021.2022.csv : temp.degC = water temperature (°C) Debit_Romaine.xlsx ROMAI_3C = turbine flow Romaine 3 (m 3 /s) ROMAI_3B = spillway flow Romaine 3 (m 3 /s) ROMAI_2C = turbine flow Romaine 2 (m 3 /s) ROMAI_2B= spillway flow Romaine 2 (m 3 /s) Ro2_EddyPro.csv "Temps" : Time "T_air (°C)" : air temperature "q (kg/kg)" : specific humidity "Patmo (Pa)" : atmospheric pressure "e (Pa)" : pressure "es (Pa)" : pressure at saturation "Zeta (-)" : stability "WS (m/s)" : wind speed "H_gf (W/m2)" : sensible heat flux "LE_gf (W/m2)" : latent heat flux "R_net (W/m2)" : net radiation "Tw (°C)" : water temperature "Hs_70m (kJ/m2)" : heat storage Ro2_hypso.csv "Altitude above sea level (m)" "Area (m2)" = area at that altitude "Ro2 ...