The WaterWorm: a low-cost, low power sensor for the detection of dissolved CH4 in glacial meltwater

An unknown source of methane (CH4) was recently discovered under the Kangerlussuaq sector of the Greenland Ice Sheet (GrIS). CH4 is transported dissolved in meltwater from the subglacial environment to the margin of the ice sheet, where it rapidly degasses to the atmosphere. Existing knowledge gaps...

Full description

Bibliographic Details
Main Authors: Elise Sapper, Sarah, Christiansen, Jesper Riis, Jørgensen, Christian Juncher
Format: Conference Object
Language:English
Published: 2022
Subjects:
Online Access:https://curis.ku.dk/portal/da/publications/the-waterworm-a-lowcost-low-power-sensor-for-the-detection-of-dissolved-ch4-in-glacial-meltwater(7279d3cb-7d96-4a6a-b79a-f81ce3dcf3a5).html
https://doi.org/10.5194/egusphere-egu22-9972
https://curis.ku.dk/ws/files/333042405/The_WaterWorm.pdf
Description
Summary:An unknown source of methane (CH4) was recently discovered under the Kangerlussuaq sector of the Greenland Ice Sheet (GrIS). CH4 is transported dissolved in meltwater from the subglacial environment to the margin of the ice sheet, where it rapidly degasses to the atmosphere. Existing knowledge gaps concern the magnitude of emissions, seasonal patterns and spatial variations along the margin of the GrIS, which require long-term monitoring and large-scale measurement campaigns at multiple meltwater outlets. A limiting factor for such studies in remote areas is that CH4 analysers (laser spectroscopy) are power-hungry, maintenance-intensive, and expensive. To overcome these obstacles, we are developing a low-cost, low power sensor for measuring dissolved CH4 in subglacial meltwater systems in the MetICE project: the WaterWorm.The WaterWorm is based on a metal oxide sensor (MOS) designed for CH4 detection (Figaro TGS2611-E00), which is highly sensitive to variations in relative humidity (RH) and temperature. In the WaterWorm, the MOS is encased in a hydrophobic but gas-permeable silicone tube, ensuring a stable and fully saturated headspace (100% RH) during submergence. We calibrated the analogue output (in mV) of the submerged WaterWorm against a reference CH4 analyser (μGGA, GLA-331, LGR Research) connected to a dissolved gas extraction system (DGES, LGR Research) in temperature-controlled laboratory experiments by stepwise enrichment of the water with CH4. These calibration tests showed that the sensor output (set at two readings per minute) is proportional to dissolved CH4 at constant humidity and temperature.During fieldwork near Kangerlussuaq, Greenland, in summer 2021, a field baseline calibration was performed in a meltwater stream on the surface of the GrIS at ambient CH4 concentrations. WaterWorms were deployed for ten weeks in the meltwater of a small outlet of the Isunnguata Sermia glacier with known CH4 export and stable meltwater temperatures (0.0 - 0.1°C) to test the sensor under field conditions. ...