Measurement of the muon lifetime and the Michel spectrum in the LAGO water Cherenkov detectors as a tool to enhance the signal-to-noise ratio
The Latin American Giant Observatory (LAGO) consists of a network of water Cherenkov detectors (WCDs) installed in the Latin American region at various latitudes, from Sierra Negra in Mexico ,and altitudes from Lima, Peru at 20 m a.s.l. to Chacaltaya, Bolivia at 5500 m a.s.l. to the Antarctic Penins...
Published in: | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment |
---|---|
Main Authors: | , , , , , |
Format: | Article in Journal/Newspaper |
Language: | English |
Published: |
Elsevier Science
|
Subjects: | |
Online Access: | http://hdl.handle.net/11336/225237 |
_version_ | 1821776761241731072 |
---|---|
author | Otiniano, L. Taboada Nuñez, Alvaro Asorey, Hernán Gonzalo Sidelnik, Iván Pedro Castromonte, C. Fauth, A. |
author_facet | Otiniano, L. Taboada Nuñez, Alvaro Asorey, Hernán Gonzalo Sidelnik, Iván Pedro Castromonte, C. Fauth, A. |
author_sort | Otiniano, L. |
collection | CONICET Digital (Consejo Nacional de Investigaciones Científicas y Técnicas) |
container_start_page | 168567 |
container_title | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment |
container_volume | 1056 |
description | The Latin American Giant Observatory (LAGO) consists of a network of water Cherenkov detectors (WCDs) installed in the Latin American region at various latitudes, from Sierra Negra in Mexico ,and altitudes from Lima, Peru at 20 m a.s.l. to Chacaltaya, Bolivia at 5500 m a.s.l. to the Antarctic Peninsula. The detectors of the network are built from commercial water tanks, so they have several geometries (cylindrical in general) and different water purification methods. All these features generate different profiles in the response to air shower particles measured by our detectors and produce pulse-shaped electronic signals. Common sources of noise in a WCD come from light leakage, electronic noise, and noise associated with the operation of photomultiplier tubes (PMTs) such as thermionic emission and after-pulses; they all could produce detectable pulses recorded by the LAGO data acquisition (DAQ) system. In LAGO WCDs, these noise signals are expected to present a short pulse width (of a few nanoseconds), while secondary radiation typically produces pulses of several tens of nanoseconds.We used data from the LAGO DAQ system, which digitises pulses at 40 MHz sampling rate on windows of 300 ns (12 temporal bins) and with a 10-bit resolution. The LAGO DAQ configuration uses a single threshold-based trigger in the third temporal bin. We proposed a secondary trigger threshold at the fourth bin to improve the noise rejection. In this work, we show how the optimal values for these triggers are now obtained from the measurement of the muon lifetime within the water volume and the resulting Michel spectrum. Our results were also simulated using the LAGO ARTI simulation framework to estimate the expected flux of secondary particles at the detector site; and the Meiga framework, a Geant4-based simulator used to estimate the WCDs response to the atmospheric radiation flux. Fil: Otiniano, L. Universidad Nacional de Ingenieria; Perú Fil: Taboada Nuñez, Alvaro. Consejo Nacional de Investigaciones Científicas y Técnicas. ... |
format | Article in Journal/Newspaper |
genre | Antarc* Antarctic Antarctic Peninsula |
genre_facet | Antarc* Antarctic Antarctic Peninsula |
geographic | Antarctic The Antarctic Antarctic Peninsula Alvaro |
geographic_facet | Antarctic The Antarctic Antarctic Peninsula Alvaro |
id | ftconicet:oai:ri.conicet.gov.ar:11336/225237 |
institution | Open Polar |
language | English |
long_lat | ENVELOPE(-63.017,-63.017,-64.850,-64.850) |
op_collection_id | ftconicet |
op_doi | https://doi.org/10.1016/j.nima.2023.168567 |
op_relation | info:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S0168900223005570 info:eu-repo/semantics/altIdentifier/doi/10.1016/j.nima.2023.168567 http://hdl.handle.net/11336/225237 CONICET Digital CONICET |
op_rights | info:eu-repo/semantics/restrictedAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
publisher | Elsevier Science |
record_format | openpolar |
spelling | ftconicet:oai:ri.conicet.gov.ar:11336/225237 2025-01-16T19:42:10+00:00 Measurement of the muon lifetime and the Michel spectrum in the LAGO water Cherenkov detectors as a tool to enhance the signal-to-noise ratio Otiniano, L. Taboada Nuñez, Alvaro Asorey, Hernán Gonzalo Sidelnik, Iván Pedro Castromonte, C. Fauth, A. application/pdf http://hdl.handle.net/11336/225237 eng eng Elsevier Science info:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S0168900223005570 info:eu-repo/semantics/altIdentifier/doi/10.1016/j.nima.2023.168567 http://hdl.handle.net/11336/225237 CONICET Digital CONICET info:eu-repo/semantics/restrictedAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ cherenkov radiation michel spectrum LAGO https://purl.org/becyt/ford/1.3 https://purl.org/becyt/ford/1 info:eu-repo/semantics/article info:ar-repo/semantics/artículo info:eu-repo/semantics/publishedVersion ftconicet https://doi.org/10.1016/j.nima.2023.168567 2024-10-04T09:34:11Z The Latin American Giant Observatory (LAGO) consists of a network of water Cherenkov detectors (WCDs) installed in the Latin American region at various latitudes, from Sierra Negra in Mexico ,and altitudes from Lima, Peru at 20 m a.s.l. to Chacaltaya, Bolivia at 5500 m a.s.l. to the Antarctic Peninsula. The detectors of the network are built from commercial water tanks, so they have several geometries (cylindrical in general) and different water purification methods. All these features generate different profiles in the response to air shower particles measured by our detectors and produce pulse-shaped electronic signals. Common sources of noise in a WCD come from light leakage, electronic noise, and noise associated with the operation of photomultiplier tubes (PMTs) such as thermionic emission and after-pulses; they all could produce detectable pulses recorded by the LAGO data acquisition (DAQ) system. In LAGO WCDs, these noise signals are expected to present a short pulse width (of a few nanoseconds), while secondary radiation typically produces pulses of several tens of nanoseconds.We used data from the LAGO DAQ system, which digitises pulses at 40 MHz sampling rate on windows of 300 ns (12 temporal bins) and with a 10-bit resolution. The LAGO DAQ configuration uses a single threshold-based trigger in the third temporal bin. We proposed a secondary trigger threshold at the fourth bin to improve the noise rejection. In this work, we show how the optimal values for these triggers are now obtained from the measurement of the muon lifetime within the water volume and the resulting Michel spectrum. Our results were also simulated using the LAGO ARTI simulation framework to estimate the expected flux of secondary particles at the detector site; and the Meiga framework, a Geant4-based simulator used to estimate the WCDs response to the atmospheric radiation flux. Fil: Otiniano, L. Universidad Nacional de Ingenieria; Perú Fil: Taboada Nuñez, Alvaro. Consejo Nacional de Investigaciones Científicas y Técnicas. ... Article in Journal/Newspaper Antarc* Antarctic Antarctic Peninsula CONICET Digital (Consejo Nacional de Investigaciones Científicas y Técnicas) Antarctic The Antarctic Antarctic Peninsula Alvaro ENVELOPE(-63.017,-63.017,-64.850,-64.850) Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 1056 168567 |
spellingShingle | cherenkov radiation michel spectrum LAGO https://purl.org/becyt/ford/1.3 https://purl.org/becyt/ford/1 Otiniano, L. Taboada Nuñez, Alvaro Asorey, Hernán Gonzalo Sidelnik, Iván Pedro Castromonte, C. Fauth, A. Measurement of the muon lifetime and the Michel spectrum in the LAGO water Cherenkov detectors as a tool to enhance the signal-to-noise ratio |
title | Measurement of the muon lifetime and the Michel spectrum in the LAGO water Cherenkov detectors as a tool to enhance the signal-to-noise ratio |
title_full | Measurement of the muon lifetime and the Michel spectrum in the LAGO water Cherenkov detectors as a tool to enhance the signal-to-noise ratio |
title_fullStr | Measurement of the muon lifetime and the Michel spectrum in the LAGO water Cherenkov detectors as a tool to enhance the signal-to-noise ratio |
title_full_unstemmed | Measurement of the muon lifetime and the Michel spectrum in the LAGO water Cherenkov detectors as a tool to enhance the signal-to-noise ratio |
title_short | Measurement of the muon lifetime and the Michel spectrum in the LAGO water Cherenkov detectors as a tool to enhance the signal-to-noise ratio |
title_sort | measurement of the muon lifetime and the michel spectrum in the lago water cherenkov detectors as a tool to enhance the signal-to-noise ratio |
topic | cherenkov radiation michel spectrum LAGO https://purl.org/becyt/ford/1.3 https://purl.org/becyt/ford/1 |
topic_facet | cherenkov radiation michel spectrum LAGO https://purl.org/becyt/ford/1.3 https://purl.org/becyt/ford/1 |
url | http://hdl.handle.net/11336/225237 |