1Graduate Student

Several mix &signs of a Ciment Fondu based grout were tested in the laboratory to develop a grout which would perform adequately as a pile back611 material in permafrost as wld as-lO°C. The test procedure and results of thermal, compressive strength. and workability performance of the different...

Full description

Bibliographic Details
Main Authors: Cold Setting, Ciment Fondu Grout, K. W. Biggar, D. C. Sego
Other Authors: The Pennsylvania State University CiteSeerX Archives
Format: Text
Language:English
Subjects:
Online Access:http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.513.7811
http://pubs.aina.ucalgary.ca/cpc/CPC5-349.pdf
Description
Summary:Several mix &signs of a Ciment Fondu based grout were tested in the laboratory to develop a grout which would perform adequately as a pile back611 material in permafrost as wld as-lO°C. The test procedure and results of thermal, compressive strength. and workability performance of the different mix designs are described in &tail. Resume Plusieurs m6langes de codis B base de ccciment Fondu * ont 6t6s exp6riment6s en laboratoire afrn de dbvelopper un coulis pouvant se wmporter de fapn adequate comme mat6riel de remplissage pour des pieux implant6s dam le perg6lisol jusqu'B-lO°C. L'exp6rimentation ainsi que les rbsultats en terme & performance thermique. de rbsistance en compression et de maniabilit6 pour les diffbrent m6langes sont