Atmospheric aerosol and Cloud Condensation Nuclei concentrations from Macquarie Island from 2016 to 2018.

Ambient aerosol data, including condensation nuclei larger than 10 nm (CN10) and cloud condensation nuclei at a range of supersaturations, were collected in the clean air laboratory at the Australian research station on Macquarie Island located in the Southern Ocean. Data from two instruments are re...

Full description

Bibliographic Details
Other Authors: CSIRO (hasAssociationWith), CSIRO (isManagedBy)
Format: Dataset
Language:unknown
Published: Commonwealth Scientific and Industrial Research Organisation
Subjects:
ccn
Online Access:https://researchdata.edu.au/atmospheric-aerosol-cloud-2016-2018/1893429
https://doi.org/10.25919/g7jx-k629
Description
Summary:Ambient aerosol data, including condensation nuclei larger than 10 nm (CN10) and cloud condensation nuclei at a range of supersaturations, were collected in the clean air laboratory at the Australian research station on Macquarie Island located in the Southern Ocean. Data from two instruments are reported in this dataset: - TSI CPC 3772 – measures the total number concentration of aerosols with diameters larger than 10 nm (CN10) - DMT CCNC-100 – measures the total number concentration of cloud condensation nuclei at specified supersaturations as determined by the user. Sample air was drawn into the clean air laboratory through a sample inlet positioned 1.5 m above the roofline (~4 m above ground level). The sample line was a bespoke design with a TSP (Total Suspended Particles) weather hat mounted atop a vertical 3” stainless tubing which provided both protection and vertical stability in the high wind environment. Through a bored-out Swagelok bulkhead fitting, ¾” stainless steel tubing penetrated to the height of the weather hat. The weather hat had 3 tie-down holes for guy wires to be attached for stabilisation. The top metre of the inlet, together with the weather hat were heated continuously to prevent icing with self-regulating heater tape designed to prevent ice build-up on commercial walk-in freezer doors. Heater tape was covered in insulation and then weather and UV-proof heat-shrink. The ¾” tubing that penetrated through the roof was connected inside the lab to a PM2.5 very sharp cut cyclone (VSCC), with a bypass flow set by a mass flow controller to be 16.67 LPM moving through the VSCC. Both the CCNC and CPC sampled air off the bypass flow at flow rates of 0.5 LPM and 1.0 LPM, respectively. Once quality controlled, CPC concentration data were resampled from 1 Hz to an hourly timebase, with various statistics calculated and presented including: • cn_med – median CN number concentration (units cm-3) • cn_mad – median absolute deviation of CN (units cm-3) • cn_avg – mean CN number concentration (units ...