A statistical approach to quantify uncertainty in carbon monoxide measurements at the Izaña global GAW station: 2008–2011 [Discussion paper]

Atmospheric CO in situ measurements are carried out at the Izaña (Tenerife) global GAW (Global Atmosphere Watch Programme of the World Meteorological Organization – WMO) mountain station using a Reduction Gas Analyser (RGA). In situ measurements at Izaña are representative of the subtropical Northea...

Full description

Bibliographic Details
Main Authors: Gómez Peláez, Ángel Jesús, Ramos López, Ramón, Gómez-Trueba, Vanessa, Novelli, Paul C., Campo Hernández, Rubén del
Format: Article in Journal/Newspaper
Language:English
Published: European Geosciences Union 2012
Subjects:
Online Access:https://hdl.handle.net/20.500.11765/6555
Description
Summary:Atmospheric CO in situ measurements are carried out at the Izaña (Tenerife) global GAW (Global Atmosphere Watch Programme of the World Meteorological Organization – WMO) mountain station using a Reduction Gas Analyser (RGA). In situ measurements at Izaña are representative of the subtropical Northeast Atlantic free troposphere, especially during nighttime. We present the measurement system configuration, the response function, the calibration scheme, the data processing, the Izaña 2008–2011 CO nocturnal time series, and the mean diurnal cycle by months.