Harmonization Study Between LC‐ MS/ MS and Diasorin RIA for Measurement of 25‐Hydroxyvitamin D Concentrations in a Large Population Survey

Background Population‐based research on vitamin D has increased dramatically in recent years. Such studies are typically reliant on assay procedures to measure reliable and comparable levels of 25‐hydroxyvitamin D [25( OH )D] concentrations. Methods Concentrations of 25( OH )D 3 and 25( OH )D 2 were...

Full description

Bibliographic Details
Published in:Journal of Clinical Laboratory Analysis
Main Authors: Berry, Diane J., Dutton, John, Fraser, William D., Järvelin, Marjo‐Riitta, Hyppönen, Elina
Other Authors: Suomen Akatemia, Oulun Yliopisto
Format: Article in Journal/Newspaper
Language:English
Published: Wiley 2016
Subjects:
Online Access:http://dx.doi.org/10.1002/jcla.22049
https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1002%2Fjcla.22049
https://onlinelibrary.wiley.com/doi/pdf/10.1002/jcla.22049
id crwiley:10.1002/jcla.22049
record_format openpolar
spelling crwiley:10.1002/jcla.22049 2024-09-15T18:25:41+00:00 Harmonization Study Between LC‐ MS/ MS and Diasorin RIA for Measurement of 25‐Hydroxyvitamin D Concentrations in a Large Population Survey Berry, Diane J. Dutton, John Fraser, William D. Järvelin, Marjo‐Riitta Hyppönen, Elina Suomen Akatemia Oulun Yliopisto 2016 http://dx.doi.org/10.1002/jcla.22049 https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1002%2Fjcla.22049 https://onlinelibrary.wiley.com/doi/pdf/10.1002/jcla.22049 en eng Wiley http://creativecommons.org/licenses/by/4.0/ Journal of Clinical Laboratory Analysis volume 31, issue 3 ISSN 0887-8013 1098-2825 journal-article 2016 crwiley https://doi.org/10.1002/jcla.22049 2024-07-25T04:23:20Z Background Population‐based research on vitamin D has increased dramatically in recent years. Such studies are typically reliant on assay procedures to measure reliable and comparable levels of 25‐hydroxyvitamin D [25( OH )D] concentrations. Methods Concentrations of 25( OH )D 3 and 25( OH )D 2 were measured using LC ‐ MS / MS in 5,915 participants (aged 31 years) of Northern Finland Birth Cohort 1966. Blood samples were assayed in batches over a course of 18 months. As anomalies were present in the measurements, 200 samples were reassayed using Diasorin RIA . Agreement between measurements was assessed by Passing–Bablok regression and limits of agreement (LoA). To harmonize LC ‐ MS / MS with Diasorin RIA measurements, formulae were derived from the LoA. Results Concentrations measured by LC ‐ MS / MS were much higher than those measured by Diasorin RIA , with a mean difference of 12.9 ng/ ml . Constant variation was evident between batch measurements after log transformation. Statistical formula was applied separately for each batch of LC ‐ MS / MS measurements, enabling us to remove both the constant and proportional bias that was evident prior to the transformation. Conclusion Despite the introduction of schemes/programs to improve accuracy of assays to measure 25( OH )D, significant differences can still happen. In these instances, methods to harmonize measurements based on a relatively small number of replicates can be successfully applied to establish confidence and to enable between‐study comparisons. Article in Journal/Newspaper Northern Finland Wiley Online Library Journal of Clinical Laboratory Analysis 31 3
institution Open Polar
collection Wiley Online Library
op_collection_id crwiley
language English
description Background Population‐based research on vitamin D has increased dramatically in recent years. Such studies are typically reliant on assay procedures to measure reliable and comparable levels of 25‐hydroxyvitamin D [25( OH )D] concentrations. Methods Concentrations of 25( OH )D 3 and 25( OH )D 2 were measured using LC ‐ MS / MS in 5,915 participants (aged 31 years) of Northern Finland Birth Cohort 1966. Blood samples were assayed in batches over a course of 18 months. As anomalies were present in the measurements, 200 samples were reassayed using Diasorin RIA . Agreement between measurements was assessed by Passing–Bablok regression and limits of agreement (LoA). To harmonize LC ‐ MS / MS with Diasorin RIA measurements, formulae were derived from the LoA. Results Concentrations measured by LC ‐ MS / MS were much higher than those measured by Diasorin RIA , with a mean difference of 12.9 ng/ ml . Constant variation was evident between batch measurements after log transformation. Statistical formula was applied separately for each batch of LC ‐ MS / MS measurements, enabling us to remove both the constant and proportional bias that was evident prior to the transformation. Conclusion Despite the introduction of schemes/programs to improve accuracy of assays to measure 25( OH )D, significant differences can still happen. In these instances, methods to harmonize measurements based on a relatively small number of replicates can be successfully applied to establish confidence and to enable between‐study comparisons.
author2 Suomen Akatemia
Oulun Yliopisto
format Article in Journal/Newspaper
author Berry, Diane J.
Dutton, John
Fraser, William D.
Järvelin, Marjo‐Riitta
Hyppönen, Elina
spellingShingle Berry, Diane J.
Dutton, John
Fraser, William D.
Järvelin, Marjo‐Riitta
Hyppönen, Elina
Harmonization Study Between LC‐ MS/ MS and Diasorin RIA for Measurement of 25‐Hydroxyvitamin D Concentrations in a Large Population Survey
author_facet Berry, Diane J.
Dutton, John
Fraser, William D.
Järvelin, Marjo‐Riitta
Hyppönen, Elina
author_sort Berry, Diane J.
title Harmonization Study Between LC‐ MS/ MS and Diasorin RIA for Measurement of 25‐Hydroxyvitamin D Concentrations in a Large Population Survey
title_short Harmonization Study Between LC‐ MS/ MS and Diasorin RIA for Measurement of 25‐Hydroxyvitamin D Concentrations in a Large Population Survey
title_full Harmonization Study Between LC‐ MS/ MS and Diasorin RIA for Measurement of 25‐Hydroxyvitamin D Concentrations in a Large Population Survey
title_fullStr Harmonization Study Between LC‐ MS/ MS and Diasorin RIA for Measurement of 25‐Hydroxyvitamin D Concentrations in a Large Population Survey
title_full_unstemmed Harmonization Study Between LC‐ MS/ MS and Diasorin RIA for Measurement of 25‐Hydroxyvitamin D Concentrations in a Large Population Survey
title_sort harmonization study between lc‐ ms/ ms and diasorin ria for measurement of 25‐hydroxyvitamin d concentrations in a large population survey
publisher Wiley
publishDate 2016
url http://dx.doi.org/10.1002/jcla.22049
https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1002%2Fjcla.22049
https://onlinelibrary.wiley.com/doi/pdf/10.1002/jcla.22049
genre Northern Finland
genre_facet Northern Finland
op_source Journal of Clinical Laboratory Analysis
volume 31, issue 3
ISSN 0887-8013 1098-2825
op_rights http://creativecommons.org/licenses/by/4.0/
op_doi https://doi.org/10.1002/jcla.22049
container_title Journal of Clinical Laboratory Analysis
container_volume 31
container_issue 3
_version_ 1810466167144316928