Seismic resistance estimation of existing turbogenerator foundation structures under ductility level earthquake impact by nonlinear static method

Abstract The article considers the multimodal nonlinear static method as a seismic resistance estimation method of existing turbogenerator foundation structures. The object of research is the turbogenerator foundation on the Tom-Usinsk State District Power Station. The article proposes a modified al...

Full description

Bibliographic Details
Published in:IOP Conference Series: Materials Science and Engineering
Main Authors: Zubritskiy, Maksim, Ushakov, Oleg, Sabitov, Linar, Bambulevich, Maksim, Akhtyamova, Leysan
Format: Article in Journal/Newspaper
Language:unknown
Published: IOP Publishing 2021
Subjects:
Online Access:http://dx.doi.org/10.1088/1757-899x/1030/1/012028
https://iopscience.iop.org/article/10.1088/1757-899X/1030/1/012028/pdf
https://iopscience.iop.org/article/10.1088/1757-899X/1030/1/012028
Description
Summary:Abstract The article considers the multimodal nonlinear static method as a seismic resistance estimation method of existing turbogenerator foundation structures. The object of research is the turbogenerator foundation on the Tom-Usinsk State District Power Station. The article proposes a modified algorithm for the characteristic point search by the nonlinear static method. According to the calculations results, the existing foundation structures after a partial equipment replacement and the construction site increased seismicity are operational.