Can collected hygrothermal data illustrate observed thermal problems of the façade? – A case study from Greenland

Abstract Buildings are more vulnerable to faults in design and construction, when exposed to the extreme Greenlandic climate, however, most new materials and designs have not been tested for Arctic conditions. Thus even minor errors can result in failures like mould growth, discomfort, and unnecessa...

Full description

Bibliographic Details
Published in:Journal of Physics: Conference Series
Main Authors: Friis, N K, Møller, E B, Lading, T
Format: Article in Journal/Newspaper
Language:unknown
Published: IOP Publishing 2021
Subjects:
Online Access:http://dx.doi.org/10.1088/1742-6596/2069/1/012071
https://iopscience.iop.org/article/10.1088/1742-6596/2069/1/012071
https://iopscience.iop.org/article/10.1088/1742-6596/2069/1/012071/pdf
id crioppubl:10.1088/1742-6596/2069/1/012071
record_format openpolar
spelling crioppubl:10.1088/1742-6596/2069/1/012071 2024-06-02T08:02:24+00:00 Can collected hygrothermal data illustrate observed thermal problems of the façade? – A case study from Greenland Friis, N K Møller, E B Lading, T 2021 http://dx.doi.org/10.1088/1742-6596/2069/1/012071 https://iopscience.iop.org/article/10.1088/1742-6596/2069/1/012071 https://iopscience.iop.org/article/10.1088/1742-6596/2069/1/012071/pdf unknown IOP Publishing http://creativecommons.org/licenses/by/3.0/ https://iopscience.iop.org/info/page/text-and-data-mining Journal of Physics: Conference Series volume 2069, issue 1, page 012071 ISSN 1742-6588 1742-6596 journal-article 2021 crioppubl https://doi.org/10.1088/1742-6596/2069/1/012071 2024-05-07T13:57:37Z Abstract Buildings are more vulnerable to faults in design and construction, when exposed to the extreme Greenlandic climate, however, most new materials and designs have not been tested for Arctic conditions. Thus even minor errors can result in failures like mould growth, discomfort, and unnecessary heat loss. Rekognizing the source of the error can be difficult, yet valuable. But how can it be identified whether the error lies in the design or quality of workmanship? This paper describes a case study from Nuuk, Greenland, where a new mineral wool insulation system was implemented. Residents were complaining about draft and cold areas. An investigation revealed that inaccurate use of the system caused several problems. Simulations of the exterior wall performance were conducted and compared to measurements. This paper discusses whether these measurements and simulations support the identified issues, and therefore if this kind of general surveillance of exterior walls can be used to determine the total performance of an exterior wall. The paper concludes that the collected data can support the issues of the complaints, and that the fundamental reasons for the problems are the design, the precision of the casted concrete and the lack of a wind barrier protecting the insulation. Article in Journal/Newspaper Arctic Greenland greenlandic Nuuk IOP Publishing Arctic Greenland Nuuk ENVELOPE(-52.150,-52.150,68.717,68.717) Journal of Physics: Conference Series 2069 1 012071
institution Open Polar
collection IOP Publishing
op_collection_id crioppubl
language unknown
description Abstract Buildings are more vulnerable to faults in design and construction, when exposed to the extreme Greenlandic climate, however, most new materials and designs have not been tested for Arctic conditions. Thus even minor errors can result in failures like mould growth, discomfort, and unnecessary heat loss. Rekognizing the source of the error can be difficult, yet valuable. But how can it be identified whether the error lies in the design or quality of workmanship? This paper describes a case study from Nuuk, Greenland, where a new mineral wool insulation system was implemented. Residents were complaining about draft and cold areas. An investigation revealed that inaccurate use of the system caused several problems. Simulations of the exterior wall performance were conducted and compared to measurements. This paper discusses whether these measurements and simulations support the identified issues, and therefore if this kind of general surveillance of exterior walls can be used to determine the total performance of an exterior wall. The paper concludes that the collected data can support the issues of the complaints, and that the fundamental reasons for the problems are the design, the precision of the casted concrete and the lack of a wind barrier protecting the insulation.
format Article in Journal/Newspaper
author Friis, N K
Møller, E B
Lading, T
spellingShingle Friis, N K
Møller, E B
Lading, T
Can collected hygrothermal data illustrate observed thermal problems of the façade? – A case study from Greenland
author_facet Friis, N K
Møller, E B
Lading, T
author_sort Friis, N K
title Can collected hygrothermal data illustrate observed thermal problems of the façade? – A case study from Greenland
title_short Can collected hygrothermal data illustrate observed thermal problems of the façade? – A case study from Greenland
title_full Can collected hygrothermal data illustrate observed thermal problems of the façade? – A case study from Greenland
title_fullStr Can collected hygrothermal data illustrate observed thermal problems of the façade? – A case study from Greenland
title_full_unstemmed Can collected hygrothermal data illustrate observed thermal problems of the façade? – A case study from Greenland
title_sort can collected hygrothermal data illustrate observed thermal problems of the façade? – a case study from greenland
publisher IOP Publishing
publishDate 2021
url http://dx.doi.org/10.1088/1742-6596/2069/1/012071
https://iopscience.iop.org/article/10.1088/1742-6596/2069/1/012071
https://iopscience.iop.org/article/10.1088/1742-6596/2069/1/012071/pdf
long_lat ENVELOPE(-52.150,-52.150,68.717,68.717)
geographic Arctic
Greenland
Nuuk
geographic_facet Arctic
Greenland
Nuuk
genre Arctic
Greenland
greenlandic
Nuuk
genre_facet Arctic
Greenland
greenlandic
Nuuk
op_source Journal of Physics: Conference Series
volume 2069, issue 1, page 012071
ISSN 1742-6588 1742-6596
op_rights http://creativecommons.org/licenses/by/3.0/
https://iopscience.iop.org/info/page/text-and-data-mining
op_doi https://doi.org/10.1088/1742-6596/2069/1/012071
container_title Journal of Physics: Conference Series
container_volume 2069
container_issue 1
container_start_page 012071
_version_ 1800746897706582016