Evaluation of methods to determine sperm density for the European eel, Anguilla anguilla
European eel, Anguilla anguilla, is a target species for future captive breeding, yet best methodology to estimate sperm density for application in in vitro fertilization is not established. Thus, our objectives were to evaluate methods to estimate European eel sperm density including spermatocrit,...
Published in: | Reproduction in Domestic Animals |
---|---|
Main Authors: | , , , , , |
Format: | Article in Journal/Newspaper |
Language: | unknown |
Published: |
Zenodo
2013
|
Subjects: | |
Online Access: | https://doi.org/10.1111/rda.12189 |
_version_ | 1821492594038800384 |
---|---|
author | Sorensen, S.R. Gallego, V. Perez, L. Butts, I.A.E. Tomkiewicz, J. Asturiano, J.F. |
author_facet | Sorensen, S.R. Gallego, V. Perez, L. Butts, I.A.E. Tomkiewicz, J. Asturiano, J.F. |
author_sort | Sorensen, S.R. |
collection | Zenodo |
container_issue | 6 |
container_start_page | 936 |
container_title | Reproduction in Domestic Animals |
container_volume | 48 |
description | European eel, Anguilla anguilla, is a target species for future captive breeding, yet best methodology to estimate sperm density for application in in vitro fertilization is not established. Thus, our objectives were to evaluate methods to estimate European eel sperm density including spermatocrit, computer assisted sperm analysis (CASA) and flow-cytometry (FCM), using Neubauer Improved hemocytometer as benchmark. Initially, relationships between spermatocrit, hemocytometer counts, and sperm motility were analyzed, as well as the effect of sperm dilution on hemocytometer counts. Furthermore, accuracy and precision of permatocrit, applying a range of G-forces, were tested and the best G-force used in method comparisons. We found no effect of dilution on hemocytometer sperm density estimates, whereas motility associated positively with hemocytometer counts, but not with spermatocrit. Results from all techniques, spermatocrit, CASA and FCM, showed significant positive correlations with hemocytometer counts. The best correlation between spermatocrit and hemocytometer counts was obtained at 6000 × g (r = 0.68). Out of two CASA variants, one or three photographic fields (CASA-1 and CASA-2), CASA-2 showed a very high accuracy to hemocytometer counts (r = 0.93), but low precision (CV: CASA-2 =28.4%). FCM was tested with and without microfluorospheres (FCM-1 and FCM-2,) and relationships to hemocytometer counts were highly accurate (FCM-1: r = 0.94; 45 FCM-2: r = 0.88) and precise (CV: FCM-1 = 2.5; FCM-2 = 2.7%). Overall, CASA-2 46 and FCM-1 feature reliable methods for quantification of European eel sperm, but FCM-1 has a clear advantage featuring highest precision and accuracy. Together, these results provide a useful basis for gamete management in fertilization protocols. |
format | Article in Journal/Newspaper |
genre | Anguilla anguilla European eel |
genre_facet | Anguilla anguilla European eel |
id | ftzenodo:oai:zenodo.org:7560 |
institution | Open Polar |
language | unknown |
op_collection_id | ftzenodo |
op_container_end_page | 944 |
op_doi | https://doi.org/10.1111/rda.12189 |
op_relation | https://zenodo.org/communities/proeel https://zenodo.org/communities/eu https://doi.org/10.1111/rda.12189 oai:zenodo.org:7560 |
op_rights | info:eu-repo/semantics/openAccess Creative Commons Attribution 4.0 International https://creativecommons.org/licenses/by/4.0/legalcode |
publishDate | 2013 |
publisher | Zenodo |
record_format | openpolar |
spelling | ftzenodo:oai:zenodo.org:7560 2025-01-16T18:57:20+00:00 Evaluation of methods to determine sperm density for the European eel, Anguilla anguilla Sorensen, S.R. Gallego, V. Perez, L. Butts, I.A.E. Tomkiewicz, J. Asturiano, J.F. 2013-07-18 https://doi.org/10.1111/rda.12189 unknown Zenodo https://zenodo.org/communities/proeel https://zenodo.org/communities/eu https://doi.org/10.1111/rda.12189 oai:zenodo.org:7560 info:eu-repo/semantics/openAccess Creative Commons Attribution 4.0 International https://creativecommons.org/licenses/by/4.0/legalcode european eel Anguilla anguilla reproduction aquaculture info:eu-repo/semantics/article 2013 ftzenodo https://doi.org/10.1111/rda.12189 2024-12-05T20:48:10Z European eel, Anguilla anguilla, is a target species for future captive breeding, yet best methodology to estimate sperm density for application in in vitro fertilization is not established. Thus, our objectives were to evaluate methods to estimate European eel sperm density including spermatocrit, computer assisted sperm analysis (CASA) and flow-cytometry (FCM), using Neubauer Improved hemocytometer as benchmark. Initially, relationships between spermatocrit, hemocytometer counts, and sperm motility were analyzed, as well as the effect of sperm dilution on hemocytometer counts. Furthermore, accuracy and precision of permatocrit, applying a range of G-forces, were tested and the best G-force used in method comparisons. We found no effect of dilution on hemocytometer sperm density estimates, whereas motility associated positively with hemocytometer counts, but not with spermatocrit. Results from all techniques, spermatocrit, CASA and FCM, showed significant positive correlations with hemocytometer counts. The best correlation between spermatocrit and hemocytometer counts was obtained at 6000 × g (r = 0.68). Out of two CASA variants, one or three photographic fields (CASA-1 and CASA-2), CASA-2 showed a very high accuracy to hemocytometer counts (r = 0.93), but low precision (CV: CASA-2 =28.4%). FCM was tested with and without microfluorospheres (FCM-1 and FCM-2,) and relationships to hemocytometer counts were highly accurate (FCM-1: r = 0.94; 45 FCM-2: r = 0.88) and precise (CV: FCM-1 = 2.5; FCM-2 = 2.7%). Overall, CASA-2 46 and FCM-1 feature reliable methods for quantification of European eel sperm, but FCM-1 has a clear advantage featuring highest precision and accuracy. Together, these results provide a useful basis for gamete management in fertilization protocols. Article in Journal/Newspaper Anguilla anguilla European eel Zenodo Reproduction in Domestic Animals 48 6 936 944 |
spellingShingle | european eel Anguilla anguilla reproduction aquaculture Sorensen, S.R. Gallego, V. Perez, L. Butts, I.A.E. Tomkiewicz, J. Asturiano, J.F. Evaluation of methods to determine sperm density for the European eel, Anguilla anguilla |
title | Evaluation of methods to determine sperm density for the European eel, Anguilla anguilla |
title_full | Evaluation of methods to determine sperm density for the European eel, Anguilla anguilla |
title_fullStr | Evaluation of methods to determine sperm density for the European eel, Anguilla anguilla |
title_full_unstemmed | Evaluation of methods to determine sperm density for the European eel, Anguilla anguilla |
title_short | Evaluation of methods to determine sperm density for the European eel, Anguilla anguilla |
title_sort | evaluation of methods to determine sperm density for the european eel, anguilla anguilla |
topic | european eel Anguilla anguilla reproduction aquaculture |
topic_facet | european eel Anguilla anguilla reproduction aquaculture |
url | https://doi.org/10.1111/rda.12189 |