Data Set and Simulation Files used in the Manuscript Offshore Wind Farms and Isolated Oil and Gas Platforms: Perspectives and Possibilities
Computer simulation model used in the preparation of the manuscript "Offshore Wind Farms and Isolated Oil and Gas Platforms: Perspectives and Possibilities" submitted to the ASME 41st International Conference on Ocean, Offshore & Arctic Engineering (OMAE 2022). PowerFactory files DIgSI...
Main Author: | |
---|---|
Format: | Other/Unknown Material |
Language: | unknown |
Published: |
Zenodo
2022
|
Subjects: | |
Online Access: | https://doi.org/10.5281/zenodo.6095757 |
id |
ftzenodo:oai:zenodo.org:6095757 |
---|---|
record_format |
openpolar |
spelling |
ftzenodo:oai:zenodo.org:6095757 2024-09-09T19:27:45+00:00 Data Set and Simulation Files used in the Manuscript Offshore Wind Farms and Isolated Oil and Gas Platforms: Perspectives and Possibilities Daniel dos Santos Mota 2022-02-15 https://doi.org/10.5281/zenodo.6095757 unknown Zenodo https://github.com/santosmota/OMAE_2022/tree/v0.1.0 https://doi.org/10.5281/zenodo.6095756 https://doi.org/10.5281/zenodo.6095757 oai:zenodo.org:6095757 info:eu-repo/semantics/openAccess Other (Open) info:eu-repo/semantics/other 2022 ftzenodo https://doi.org/10.5281/zenodo.609575710.5281/zenodo.6095756 2024-07-26T06:42:40Z Computer simulation model used in the preparation of the manuscript "Offshore Wind Farms and Isolated Oil and Gas Platforms: Perspectives and Possibilities" submitted to the ASME 41st International Conference on Ocean, Offshore & Arctic Engineering (OMAE 2022). PowerFactory files DIgSILENT PowerFactory 2020 SP2a (x64) Build 20.0.4.1 (10037) / Rev. 73397 Model: 20201211_OMAE_BaseModel.pfd Cases Case 1: ESS is connected but does not contribute. Case 2: ESS is connected and contribute with primary reserves (a slow and small secondary resposnse is tuned in the controller). Case 3: ESS is connected and contribute wiht primary and inertial reserves (a slow and small secondary response is tuned in the controller). Case 4: same as case 3, but the DC voltage controller current feed-forward is not active. This case did not receive a special name in the paper, it was still called case 3. Raw data files aaaammdd_Case_0*_ESS.csv: ESS related measurements aaaammdd_Case_0*_PCC.csv: Measurements at the PCC, but also at the wind turbines aaaammdd_Case_0*_Freq.csv: Frequencies and speeds on the system Structure of *_ESS.csv time in seconds Vmesa_ESS_690V: voltage in pu of 690V ESS_GC: total power leaving the ac terminals of GC in MW PQ_Meas_BCs_CurrentSource: power arriving at the capacitor from ESDs in MW ESS_GC: DC voltage in pu of 1200V ESS_GC: DC current at terminals in pu of 8.333kA BC_DCLinkSide: DC current at the DC link side from the BC in pu of 3.5kA FC_DCLinkSide: DC current at the DC link side from the FCC in pu of 5kA Structure of *_PCC.csv time in seconds GG_01: speed in pu GG_02: speed in pu PQ_Meas_GG01_11kV: active power in MW PQ_Meas_GG02_11kV: active power in MW PQ_Meas_RL01_11kV: active power in MW PQ_Meas_RL02_11kV: active power in MW PQ_Meas_WF_11kV: active power in pu in MW PQ_Meas_ESS_TR_11kV: active power in MW PQ_Meas_LV_Load_11kV: active power in MW PQ_Meas_WT1_33kV: active power in MW PQ_Meas_WT2_33kV: active power in MW PQ_Meas_WT3_33kV: active power in MW GG_01: voltage in pu of 11kV Structure of ... Other/Unknown Material Arctic Zenodo Arctic |
institution |
Open Polar |
collection |
Zenodo |
op_collection_id |
ftzenodo |
language |
unknown |
description |
Computer simulation model used in the preparation of the manuscript "Offshore Wind Farms and Isolated Oil and Gas Platforms: Perspectives and Possibilities" submitted to the ASME 41st International Conference on Ocean, Offshore & Arctic Engineering (OMAE 2022). PowerFactory files DIgSILENT PowerFactory 2020 SP2a (x64) Build 20.0.4.1 (10037) / Rev. 73397 Model: 20201211_OMAE_BaseModel.pfd Cases Case 1: ESS is connected but does not contribute. Case 2: ESS is connected and contribute with primary reserves (a slow and small secondary resposnse is tuned in the controller). Case 3: ESS is connected and contribute wiht primary and inertial reserves (a slow and small secondary response is tuned in the controller). Case 4: same as case 3, but the DC voltage controller current feed-forward is not active. This case did not receive a special name in the paper, it was still called case 3. Raw data files aaaammdd_Case_0*_ESS.csv: ESS related measurements aaaammdd_Case_0*_PCC.csv: Measurements at the PCC, but also at the wind turbines aaaammdd_Case_0*_Freq.csv: Frequencies and speeds on the system Structure of *_ESS.csv time in seconds Vmesa_ESS_690V: voltage in pu of 690V ESS_GC: total power leaving the ac terminals of GC in MW PQ_Meas_BCs_CurrentSource: power arriving at the capacitor from ESDs in MW ESS_GC: DC voltage in pu of 1200V ESS_GC: DC current at terminals in pu of 8.333kA BC_DCLinkSide: DC current at the DC link side from the BC in pu of 3.5kA FC_DCLinkSide: DC current at the DC link side from the FCC in pu of 5kA Structure of *_PCC.csv time in seconds GG_01: speed in pu GG_02: speed in pu PQ_Meas_GG01_11kV: active power in MW PQ_Meas_GG02_11kV: active power in MW PQ_Meas_RL01_11kV: active power in MW PQ_Meas_RL02_11kV: active power in MW PQ_Meas_WF_11kV: active power in pu in MW PQ_Meas_ESS_TR_11kV: active power in MW PQ_Meas_LV_Load_11kV: active power in MW PQ_Meas_WT1_33kV: active power in MW PQ_Meas_WT2_33kV: active power in MW PQ_Meas_WT3_33kV: active power in MW GG_01: voltage in pu of 11kV Structure of ... |
format |
Other/Unknown Material |
author |
Daniel dos Santos Mota |
spellingShingle |
Daniel dos Santos Mota Data Set and Simulation Files used in the Manuscript Offshore Wind Farms and Isolated Oil and Gas Platforms: Perspectives and Possibilities |
author_facet |
Daniel dos Santos Mota |
author_sort |
Daniel dos Santos Mota |
title |
Data Set and Simulation Files used in the Manuscript Offshore Wind Farms and Isolated Oil and Gas Platforms: Perspectives and Possibilities |
title_short |
Data Set and Simulation Files used in the Manuscript Offshore Wind Farms and Isolated Oil and Gas Platforms: Perspectives and Possibilities |
title_full |
Data Set and Simulation Files used in the Manuscript Offshore Wind Farms and Isolated Oil and Gas Platforms: Perspectives and Possibilities |
title_fullStr |
Data Set and Simulation Files used in the Manuscript Offshore Wind Farms and Isolated Oil and Gas Platforms: Perspectives and Possibilities |
title_full_unstemmed |
Data Set and Simulation Files used in the Manuscript Offshore Wind Farms and Isolated Oil and Gas Platforms: Perspectives and Possibilities |
title_sort |
data set and simulation files used in the manuscript offshore wind farms and isolated oil and gas platforms: perspectives and possibilities |
publisher |
Zenodo |
publishDate |
2022 |
url |
https://doi.org/10.5281/zenodo.6095757 |
geographic |
Arctic |
geographic_facet |
Arctic |
genre |
Arctic |
genre_facet |
Arctic |
op_relation |
https://github.com/santosmota/OMAE_2022/tree/v0.1.0 https://doi.org/10.5281/zenodo.6095756 https://doi.org/10.5281/zenodo.6095757 oai:zenodo.org:6095757 |
op_rights |
info:eu-repo/semantics/openAccess Other (Open) |
op_doi |
https://doi.org/10.5281/zenodo.609575710.5281/zenodo.6095756 |
_version_ |
1809897126984941568 |