Experimental data: measurement campaign Hintereisferner Experiment, HEFEX.

The HEFEX micrometeorological measurement campaign was conducted during three weeks in August 2018. Measurement towers were installed on the 1. and 2. August and removed on 22. August. The measurement network consisted of five 3-m tripod towers located at an along- and an across-glacier transect to...

Full description

Bibliographic Details
Main Authors: Rebecca Mott, Ivana Stiperski, Lindsey Nicholson
Format: Dataset
Language:unknown
Published: 2020
Subjects:
Online Access:https://zenodo.org/record/4113867
https://doi.org/10.5281/zenodo.4113867
id ftzenodo:oai:zenodo.org:4113867
record_format openpolar
spelling ftzenodo:oai:zenodo.org:4113867 2023-06-06T11:59:49+02:00 Experimental data: measurement campaign Hintereisferner Experiment, HEFEX. Rebecca Mott Ivana Stiperski Lindsey Nicholson 2020-10-21 https://zenodo.org/record/4113867 https://doi.org/10.5281/zenodo.4113867 unknown info:eu-repo/grantAgreement/SNSF/Careers%3BFellowships/P300P2_164644/ doi:10.5281/zenodo.4113866 https://zenodo.org/record/4113867 https://doi.org/10.5281/zenodo.4113867 oai:zenodo.org:4113867 info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by/4.0/legalcode The Cryosphere info:eu-repo/semantics/other dataset 2020 ftzenodo https://doi.org/10.5281/zenodo.411386710.5281/zenodo.4113866 2023-04-13T22:11:20Z The HEFEX micrometeorological measurement campaign was conducted during three weeks in August 2018. Measurement towers were installed on the 1. and 2. August and removed on 22. August. The measurement network consisted of five 3-m tripod towers located at an along- and an across-glacier transect to capture the spatial variations of the atmospheric flow system at the glacier and associated heat exchange processes. The across-glacier transect consisted of three turbulence towers installed from the peripheral zones of the glacier towards the centreline. The location of the across-glacier transect coincides with where the valley of Langtaufererjochferner discharges into the valley of the Hintereisferner glacier. In this area, thermal flows from the surrounding area were hypothesized to influence the surface of Hintereisferner. All stations were installed at comparatively flat areas of the glacier with slope angles varying between 6 and 8°. Measurement towers were installed directly at the ice surface. Due to pronounced changes in the ice surface caused by strong ice melt during the measurement campaign, frequent visual inspection and small adjustments to the location of the towers were essential for good data quality. This mainly consisted of repositioning the tower feet to ensure the tower stability and re-levelling the sensors. Post-processing of data, i.e. correction of data for height changes and rotation of the mast further ensured data quality Please refer to Mott et al: Spatio-temporal flow variations driving heat exchange processes at a mountain glacier, The Cryosphere, XX. for more details on data processing. Dataset The Cryosphere Zenodo
institution Open Polar
collection Zenodo
op_collection_id ftzenodo
language unknown
description The HEFEX micrometeorological measurement campaign was conducted during three weeks in August 2018. Measurement towers were installed on the 1. and 2. August and removed on 22. August. The measurement network consisted of five 3-m tripod towers located at an along- and an across-glacier transect to capture the spatial variations of the atmospheric flow system at the glacier and associated heat exchange processes. The across-glacier transect consisted of three turbulence towers installed from the peripheral zones of the glacier towards the centreline. The location of the across-glacier transect coincides with where the valley of Langtaufererjochferner discharges into the valley of the Hintereisferner glacier. In this area, thermal flows from the surrounding area were hypothesized to influence the surface of Hintereisferner. All stations were installed at comparatively flat areas of the glacier with slope angles varying between 6 and 8°. Measurement towers were installed directly at the ice surface. Due to pronounced changes in the ice surface caused by strong ice melt during the measurement campaign, frequent visual inspection and small adjustments to the location of the towers were essential for good data quality. This mainly consisted of repositioning the tower feet to ensure the tower stability and re-levelling the sensors. Post-processing of data, i.e. correction of data for height changes and rotation of the mast further ensured data quality Please refer to Mott et al: Spatio-temporal flow variations driving heat exchange processes at a mountain glacier, The Cryosphere, XX. for more details on data processing.
format Dataset
author Rebecca Mott
Ivana Stiperski
Lindsey Nicholson
spellingShingle Rebecca Mott
Ivana Stiperski
Lindsey Nicholson
Experimental data: measurement campaign Hintereisferner Experiment, HEFEX.
author_facet Rebecca Mott
Ivana Stiperski
Lindsey Nicholson
author_sort Rebecca Mott
title Experimental data: measurement campaign Hintereisferner Experiment, HEFEX.
title_short Experimental data: measurement campaign Hintereisferner Experiment, HEFEX.
title_full Experimental data: measurement campaign Hintereisferner Experiment, HEFEX.
title_fullStr Experimental data: measurement campaign Hintereisferner Experiment, HEFEX.
title_full_unstemmed Experimental data: measurement campaign Hintereisferner Experiment, HEFEX.
title_sort experimental data: measurement campaign hintereisferner experiment, hefex.
publishDate 2020
url https://zenodo.org/record/4113867
https://doi.org/10.5281/zenodo.4113867
genre The Cryosphere
genre_facet The Cryosphere
op_source The Cryosphere
op_relation info:eu-repo/grantAgreement/SNSF/Careers%3BFellowships/P300P2_164644/
doi:10.5281/zenodo.4113866
https://zenodo.org/record/4113867
https://doi.org/10.5281/zenodo.4113867
oai:zenodo.org:4113867
op_rights info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by/4.0/legalcode
op_doi https://doi.org/10.5281/zenodo.411386710.5281/zenodo.4113866
_version_ 1767950133994979328