Ensuring comfort microclimate in the classrooms under condition of the required air exchange

We performed comparative analysis of regulatory documents, which relate to ventilation of school premises and operate in European countries at present. We showed the essential difference of the recommended air exchange values. We assessed sanitary and hygienic conditions formed in classrooms at diff...

Full description

Bibliographic Details
Main Authors: Kapalo, Peter, Voznyak, Orest, Yurkevych, Yuriy, Myroniuk, Khrystyna, Sukholova, Iryna
Format: Article in Journal/Newspaper
Language:English
Ukrainian
Published: PRIVAT COMPANY "TECHNOLOGY CENTER" 2018
Subjects:
Online Access:http://journals.uran.ua/eejet/article/view/143945
id fturanojs:oai:ojs.journals.uran.ua:article/143945
record_format openpolar
institution Open Polar
collection Scientific Periodicals of Ukraine (Ukrainian Research and Academic Network)
op_collection_id fturanojs
language English
Ukrainian
topic multiplication factor of ventilation
energy saving
carbon dioxide concentration
ventilation efficiency
monitoring of microclimate
UDC 697.922.565
697.921.47
кратность вентиляции
энергосбережение
концентрация двуокиси углерода
производительность вентиляции
мониторинг микроклимата
кратність вентиляції
енергоощадність
концентрація двоокису вуглецю
продуктивність вентиляції
моніторінг мікроклімату
spellingShingle multiplication factor of ventilation
energy saving
carbon dioxide concentration
ventilation efficiency
monitoring of microclimate
UDC 697.922.565
697.921.47
кратность вентиляции
энергосбережение
концентрация двуокиси углерода
производительность вентиляции
мониторинг микроклимата
кратність вентиляції
енергоощадність
концентрація двоокису вуглецю
продуктивність вентиляції
моніторінг мікроклімату
Kapalo, Peter
Voznyak, Orest
Yurkevych, Yuriy
Myroniuk, Khrystyna
Sukholova, Iryna
Ensuring comfort microclimate in the classrooms under condition of the required air exchange
topic_facet multiplication factor of ventilation
energy saving
carbon dioxide concentration
ventilation efficiency
monitoring of microclimate
UDC 697.922.565
697.921.47
кратность вентиляции
энергосбережение
концентрация двуокиси углерода
производительность вентиляции
мониторинг микроклимата
кратність вентиляції
енергоощадність
концентрація двоокису вуглецю
продуктивність вентиляції
моніторінг мікроклімату
description We performed comparative analysis of regulatory documents, which relate to ventilation of school premises and operate in European countries at present. We showed the essential difference of the recommended air exchange values. We assessed sanitary and hygienic conditions formed in classrooms at different efficiency of a ventilation system both by analytical calculations and by subjective monitoring of microclimate of experimental measurements conducted in school classrooms, when every pupil-participant performed an assessment of the internal environment in the form of a questionnaire. We measured carbonic acid gas contents emitted in a room and determined the required ventilation intensity in the evaluated school premises. We compared the multiplication factor of air exchange of the ventilation system determined in this way with the values obtained by analytical calculations carried out in accordance with current legislation and standards, which are active in Europe. We made calculations based on known analytical dependencies. We determined performance of the ventilation system of the classroom based on СО2 concentrations in internal and inflow air at various values of the multiplication factor of air exchange. It made possible to state that we can achieve the optimal microclimate parameters at air exchange of 30 m3/h per person.We presented the results of field studies and analytical calculations in the form of tables and visual graphic dependencies. The proposed research method makes it possible to increase accuracy and reliability of air quality control in classrooms by direct measurement of СО2 concentration in a serviced area of a room. The study results provide an opportunity to improve ventilation systems of school buildings. This creates prerequisites for obtaining a social effect due to an increase in labor and learning efficiency Проведен сравнительный анализ нормативных документов, касающихся вентиляции школьных помещений, действующих сегодня европейских странах. Показано существенное отличие рекомендуемых значений воздухообмена. Оценка санитарно-гигиенических условий, формируемых в классных помещениях при разной производительности системы вентиляции, проводилась как путем аналитических расчетов, так и путем субъективного мониторинга микроклимата экспериментальных измерений, проводимых в школьных кабинетах и классах, во время которого каждый ученик-участник совершил оценку внутренней среды в форме анкеты. Было проведено измерение содержания углекислого газа, который выделялся в помещении и определено необходимую интенсивность вентиляции в оцениваемых школьных помещениях. Определенная таким образом кратность воздухообмена системы вентиляции сравнивалась с величинами, полученными путем аналитических расчетов, проводимых в соответствии с действующим законодательством и стандартами, действующими в странах Европы. Расчеты, проведенные на основании известных аналитических зависимостей, при которых производительность системы вентиляции классных помещений определялась на основании концентраций СО2 во внутреннем и приточном воздухе при различных значениях кратности воздухообмена, позволяют утверждать, что оптимальные параметры микроклимата достигаются при воздухообмене в размере 30 м3/ч на человека. Результаты натурных исследований и аналитических расчетов представлены в виде таблиц и наглядных графических зависимостей. Предложенная методика исследований позволяет повысить точность и достоверность контроля качества воздуха в классных комнатах за счет прямого измерения концентрации СО2 в обслуживаемой зоне помещения. Результаты исследований дают возможность совершенствования систем вентиляции школьных зданий. Это создает предпосылки для получения социального эффекта при повышении производительности труда и обучения Проведено порівняльний аналіз нормативних документів, які стосуються вентиляції шкільних приміщень, що діють сьогодні європейських країнах. Показано суттєву відмінність рекомендованих значень повітрообміну. Оцінка санітарно-гігієнічних умов, які формуються у класних приміщеннях при різній продуктивності системи вентиляції, проводилась як шляхом аналітичних розрахунків, так і шляхом суб’єктивного моніторингу мікроклімату експериментальних вимірювань, що проводились у шкільних кабінетах та класах, під час якого кожен учень-учасник здійснив оцінку внутрішнього середовища у формі анкети. Було проведено заміри вмісту вуглекислого газу, що виділявся в приміщенні, і визначено необхідну інтенсивність вентиляції в оцінюваних шкільних приміщеннях. Визначена таким чином кратність повітрообміну системи вентиляції порівнювалася з величинами, отриманими шляхом аналітичних розрахунків, що проводилися відповідно до чинного законодавства та стандартів, що діють в країнах Європи. Розрахунки, проведені на підставі відомих аналітичних залежностей, при яких продуктивність системи вентиляції класних приміщень визначалася на підставі концентрацій СО2 у внутрішньому та припливному повітрі при різних значеннях кратності повітрообміну дозволяють стверджувати, що оптимальні параметри мікроклімату досягаються при повітрообміні в розмірі 30 м3/год на особу. Результати натурних досліджень та аналітичних розрахунків представлено у вигляді таблиць і наочних графічних залежностей. Запропонована методика досліджень дозволяє підвищити точність та достовірність контролю якості повітря в класних кімнатах за рахунок прямого вимірювання концентрації СО2 в обслуговуваній зоні приміщення. Результати досліджень дають можливість вдосконалення систем вентиляції шкільних будівель. Це створює передумови для отримання соціального ефекту при підвищенні продуктивності праці та навчання
format Article in Journal/Newspaper
author Kapalo, Peter
Voznyak, Orest
Yurkevych, Yuriy
Myroniuk, Khrystyna
Sukholova, Iryna
author_facet Kapalo, Peter
Voznyak, Orest
Yurkevych, Yuriy
Myroniuk, Khrystyna
Sukholova, Iryna
author_sort Kapalo, Peter
title Ensuring comfort microclimate in the classrooms under condition of the required air exchange
title_short Ensuring comfort microclimate in the classrooms under condition of the required air exchange
title_full Ensuring comfort microclimate in the classrooms under condition of the required air exchange
title_fullStr Ensuring comfort microclimate in the classrooms under condition of the required air exchange
title_full_unstemmed Ensuring comfort microclimate in the classrooms under condition of the required air exchange
title_sort ensuring comfort microclimate in the classrooms under condition of the required air exchange
publisher PRIVAT COMPANY "TECHNOLOGY CENTER"
publishDate 2018
url http://journals.uran.ua/eejet/article/view/143945
genre Carbonic acid
genre_facet Carbonic acid
op_source Eastern-European Journal of Enterprise Technologies; Том 5, № 10 (95) (2018): Ecology; 6-14
Восточно-Европейский журнал передовых технологий; Том 5, № 10 (95) (2018): Экология; 6-14
Східно-Європейський журнал передових технологій; Том 5, № 10 (95) (2018): Екологія; 6-14
1729-4061
1729-3774
op_relation http://journals.uran.ua/eejet/article/view/143945/144169
http://journals.uran.ua/eejet/article/view/143945/153361
http://journals.uran.ua/eejet/article/view/143945
op_rights Copyright (c) 2018 Peter Kapalo, Orest Voznyak, Yuriy Yurkevych, Khrystyna Myroniuk, Iryna Sukholova
http://creativecommons.org/licenses/by/4.0
op_rightsnorm CC-BY
_version_ 1766388160403603456
spelling fturanojs:oai:ojs.journals.uran.ua:article/143945 2023-05-15T15:53:06+02:00 Ensuring comfort microclimate in the classrooms under condition of the required air exchange Обеспечение комфортного микроклимата в классных комнатах из условий необходимого воздухообмена Забезпечення комфортного мікроклімату у класних кімнатах за умови необхідного повітрообміну Kapalo, Peter Voznyak, Orest Yurkevych, Yuriy Myroniuk, Khrystyna Sukholova, Iryna 2018-10-09 application/pdf http://journals.uran.ua/eejet/article/view/143945 eng ukr eng ukr PRIVAT COMPANY "TECHNOLOGY CENTER" http://journals.uran.ua/eejet/article/view/143945/144169 http://journals.uran.ua/eejet/article/view/143945/153361 http://journals.uran.ua/eejet/article/view/143945 Copyright (c) 2018 Peter Kapalo, Orest Voznyak, Yuriy Yurkevych, Khrystyna Myroniuk, Iryna Sukholova http://creativecommons.org/licenses/by/4.0 CC-BY Eastern-European Journal of Enterprise Technologies; Том 5, № 10 (95) (2018): Ecology; 6-14 Восточно-Европейский журнал передовых технологий; Том 5, № 10 (95) (2018): Экология; 6-14 Східно-Європейський журнал передових технологій; Том 5, № 10 (95) (2018): Екологія; 6-14 1729-4061 1729-3774 multiplication factor of ventilation energy saving carbon dioxide concentration ventilation efficiency monitoring of microclimate UDC 697.922.565 697.921.47 кратность вентиляции энергосбережение концентрация двуокиси углерода производительность вентиляции мониторинг микроклимата кратність вентиляції енергоощадність концентрація двоокису вуглецю продуктивність вентиляції моніторінг мікроклімату info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion 2018 fturanojs 2019-01-08T00:22:30Z We performed comparative analysis of regulatory documents, which relate to ventilation of school premises and operate in European countries at present. We showed the essential difference of the recommended air exchange values. We assessed sanitary and hygienic conditions formed in classrooms at different efficiency of a ventilation system both by analytical calculations and by subjective monitoring of microclimate of experimental measurements conducted in school classrooms, when every pupil-participant performed an assessment of the internal environment in the form of a questionnaire. We measured carbonic acid gas contents emitted in a room and determined the required ventilation intensity in the evaluated school premises. We compared the multiplication factor of air exchange of the ventilation system determined in this way with the values obtained by analytical calculations carried out in accordance with current legislation and standards, which are active in Europe. We made calculations based on known analytical dependencies. We determined performance of the ventilation system of the classroom based on СО2 concentrations in internal and inflow air at various values of the multiplication factor of air exchange. It made possible to state that we can achieve the optimal microclimate parameters at air exchange of 30 m3/h per person.We presented the results of field studies and analytical calculations in the form of tables and visual graphic dependencies. The proposed research method makes it possible to increase accuracy and reliability of air quality control in classrooms by direct measurement of СО2 concentration in a serviced area of a room. The study results provide an opportunity to improve ventilation systems of school buildings. This creates prerequisites for obtaining a social effect due to an increase in labor and learning efficiency Проведен сравнительный анализ нормативных документов, касающихся вентиляции школьных помещений, действующих сегодня европейских странах. Показано существенное отличие рекомендуемых значений воздухообмена. Оценка санитарно-гигиенических условий, формируемых в классных помещениях при разной производительности системы вентиляции, проводилась как путем аналитических расчетов, так и путем субъективного мониторинга микроклимата экспериментальных измерений, проводимых в школьных кабинетах и классах, во время которого каждый ученик-участник совершил оценку внутренней среды в форме анкеты. Было проведено измерение содержания углекислого газа, который выделялся в помещении и определено необходимую интенсивность вентиляции в оцениваемых школьных помещениях. Определенная таким образом кратность воздухообмена системы вентиляции сравнивалась с величинами, полученными путем аналитических расчетов, проводимых в соответствии с действующим законодательством и стандартами, действующими в странах Европы. Расчеты, проведенные на основании известных аналитических зависимостей, при которых производительность системы вентиляции классных помещений определялась на основании концентраций СО2 во внутреннем и приточном воздухе при различных значениях кратности воздухообмена, позволяют утверждать, что оптимальные параметры микроклимата достигаются при воздухообмене в размере 30 м3/ч на человека. Результаты натурных исследований и аналитических расчетов представлены в виде таблиц и наглядных графических зависимостей. Предложенная методика исследований позволяет повысить точность и достоверность контроля качества воздуха в классных комнатах за счет прямого измерения концентрации СО2 в обслуживаемой зоне помещения. Результаты исследований дают возможность совершенствования систем вентиляции школьных зданий. Это создает предпосылки для получения социального эффекта при повышении производительности труда и обучения Проведено порівняльний аналіз нормативних документів, які стосуються вентиляції шкільних приміщень, що діють сьогодні європейських країнах. Показано суттєву відмінність рекомендованих значень повітрообміну. Оцінка санітарно-гігієнічних умов, які формуються у класних приміщеннях при різній продуктивності системи вентиляції, проводилась як шляхом аналітичних розрахунків, так і шляхом суб’єктивного моніторингу мікроклімату експериментальних вимірювань, що проводились у шкільних кабінетах та класах, під час якого кожен учень-учасник здійснив оцінку внутрішнього середовища у формі анкети. Було проведено заміри вмісту вуглекислого газу, що виділявся в приміщенні, і визначено необхідну інтенсивність вентиляції в оцінюваних шкільних приміщеннях. Визначена таким чином кратність повітрообміну системи вентиляції порівнювалася з величинами, отриманими шляхом аналітичних розрахунків, що проводилися відповідно до чинного законодавства та стандартів, що діють в країнах Європи. Розрахунки, проведені на підставі відомих аналітичних залежностей, при яких продуктивність системи вентиляції класних приміщень визначалася на підставі концентрацій СО2 у внутрішньому та припливному повітрі при різних значеннях кратності повітрообміну дозволяють стверджувати, що оптимальні параметри мікроклімату досягаються при повітрообміні в розмірі 30 м3/год на особу. Результати натурних досліджень та аналітичних розрахунків представлено у вигляді таблиць і наочних графічних залежностей. Запропонована методика досліджень дозволяє підвищити точність та достовірність контролю якості повітря в класних кімнатах за рахунок прямого вимірювання концентрації СО2 в обслуговуваній зоні приміщення. Результати досліджень дають можливість вдосконалення систем вентиляції шкільних будівель. Це створює передумови для отримання соціального ефекту при підвищенні продуктивності праці та навчання Article in Journal/Newspaper Carbonic acid Scientific Periodicals of Ukraine (Ukrainian Research and Academic Network)