Automatic measurement of glacier ice ablation using thermistor strings

In this work we tested the suitability of thermistor strings as automatic tools for the continuous measurement of glacier ice ablation. Experimental data collected in summer 2017 over an Italian glacier provided ice ablation readings with accuracy similar to manual measurements with ablation stakes...

Full description

Bibliographic Details
Published in:Journal of Glaciology
Main Authors: Carturan, L., Cazorzi, F., Dalla Fontana, G., Zanoner, T.
Format: Article in Journal/Newspaper
Language:English
Published: 2019
Subjects:
Online Access:http://hdl.handle.net/11390/1146467
https://doi.org/10.1017/jog.2018.103
https://www.cambridge.org/core/journals/journal-of-glaciology/all-issues
Description
Summary:In this work we tested the suitability of thermistor strings as automatic tools for the continuous measurement of glacier ice ablation. Experimental data collected in summer 2017 over an Italian glacier provided ice ablation readings with accuracy similar to manual measurements with ablation stakes and other automatic systems, like the draw-wire method and the Bøggild ablatometer. Thermistor strings have potential for future applications in remote glacier monitoring, thanks to their flexibility, simple construction, and robustness.