Quality of dental unit water at university dental clinic, private and public clinics in Tromsø. Investigation of bacteria levels in water samples in dental chair water lines

Abstract: Exposure to water with high bacterial counts violates the basic principles of clinical infection control in dental clinics. Therefore, bacterial counts in water that comes from the dental chair unit should always be evaluated. As guideline water that comes from hand pieces/three-way syring...

Full description

Bibliographic Details
Main Authors: Lilleng, Helga, Gangsø, Luise, Skoglund, Julie
Format: Master Thesis
Language:English
Published: UiT Norges arktiske universitet 2017
Subjects:
Online Access:https://hdl.handle.net/10037/11565
id ftunivtroemsoe:oai:munin.uit.no:10037/11565
record_format openpolar
spelling ftunivtroemsoe:oai:munin.uit.no:10037/11565 2023-05-15T18:34:38+02:00 Quality of dental unit water at university dental clinic, private and public clinics in Tromsø. Investigation of bacteria levels in water samples in dental chair water lines Lilleng, Helga Gangsø, Luise Skoglund, Julie 2017-04-19 https://hdl.handle.net/10037/11565 eng eng UiT Norges arktiske universitet UiT The Arctic University of Norway https://hdl.handle.net/10037/11565 openAccess Copyright 2017 The Author(s) VDP::Medisinske Fag: 700::Klinisk odontologiske fag: 830::Andre kliniske odontologiske fag: 849 VDP::Medical disciplines: 700::Clinical dentistry disciplines: 830::Other clinical dentistry disciplines: 849 ODO-3901 Master thesis Mastergradsoppgave 2017 ftunivtroemsoe 2021-06-25T17:55:25Z Abstract: Exposure to water with high bacterial counts violates the basic principles of clinical infection control in dental clinics. Therefore, bacterial counts in water that comes from the dental chair unit should always be evaluated. As guideline water that comes from hand pieces/three-way syringes should have less than 200 colony forming units per one mL of water. Aims: The aim of this study is to investigate levels of bacteria in dental unit water at University Dental Clinic (UDC), public and private clinics in Tromsø, and assess the hygiene procedures for dental unit water at the different clinics. Materials and methods: Water samples from dental chair at UDC, public and private clinics were obtained for microbiological analysis. Water samples were cultivated in agar plates and in prefabricated sample kits to investigate the growth of bacteria. Digital droplet PCR (ddPCR) was used to evaluate the bacterial load in these samples. Results: Differences in the amount of bacteria in water samples between UDC, private and public clinics were detected. UDC had lower bacterial load in the dental unit water than the private and the public clinics. There was a significant difference in level of E.coli counts, Heterotrophic plates counts (HPC) and the ddPCR counts between the UDC and the other two groups. There was also a significant difference between the private and the public clinics, in level of bacteria determined by the ddPCR. The public clinics had the highest level of bacteria in the water from the dental chair units. Conclusion: It seems that water coming from the dental chairs at UDC have the lowest bacterial load than the water obtained from the dental chairs at public and private clinics. The reason of high bacterial loads in the private and public clinics could be suboptimal infection control measures in these places. In addition, high bacterial load could be attributed to old pipe system and lack of stringent water filtration system within the clinics. Even though the study has shown high levels of bacterial load we cannot conclude that dental unit water is considered to be a risk for immunocompromised patients. This is because of, no attempt has been done to identify, what kind of bacteria that are present in the water and if these bacteria are pathogenic or not. Master Thesis Tromsø University of Tromsø: Munin Open Research Archive Tromsø
institution Open Polar
collection University of Tromsø: Munin Open Research Archive
op_collection_id ftunivtroemsoe
language English
topic VDP::Medisinske Fag: 700::Klinisk odontologiske fag: 830::Andre kliniske odontologiske fag: 849
VDP::Medical disciplines: 700::Clinical dentistry disciplines: 830::Other clinical dentistry disciplines: 849
ODO-3901
spellingShingle VDP::Medisinske Fag: 700::Klinisk odontologiske fag: 830::Andre kliniske odontologiske fag: 849
VDP::Medical disciplines: 700::Clinical dentistry disciplines: 830::Other clinical dentistry disciplines: 849
ODO-3901
Lilleng, Helga
Gangsø, Luise
Skoglund, Julie
Quality of dental unit water at university dental clinic, private and public clinics in Tromsø. Investigation of bacteria levels in water samples in dental chair water lines
topic_facet VDP::Medisinske Fag: 700::Klinisk odontologiske fag: 830::Andre kliniske odontologiske fag: 849
VDP::Medical disciplines: 700::Clinical dentistry disciplines: 830::Other clinical dentistry disciplines: 849
ODO-3901
description Abstract: Exposure to water with high bacterial counts violates the basic principles of clinical infection control in dental clinics. Therefore, bacterial counts in water that comes from the dental chair unit should always be evaluated. As guideline water that comes from hand pieces/three-way syringes should have less than 200 colony forming units per one mL of water. Aims: The aim of this study is to investigate levels of bacteria in dental unit water at University Dental Clinic (UDC), public and private clinics in Tromsø, and assess the hygiene procedures for dental unit water at the different clinics. Materials and methods: Water samples from dental chair at UDC, public and private clinics were obtained for microbiological analysis. Water samples were cultivated in agar plates and in prefabricated sample kits to investigate the growth of bacteria. Digital droplet PCR (ddPCR) was used to evaluate the bacterial load in these samples. Results: Differences in the amount of bacteria in water samples between UDC, private and public clinics were detected. UDC had lower bacterial load in the dental unit water than the private and the public clinics. There was a significant difference in level of E.coli counts, Heterotrophic plates counts (HPC) and the ddPCR counts between the UDC and the other two groups. There was also a significant difference between the private and the public clinics, in level of bacteria determined by the ddPCR. The public clinics had the highest level of bacteria in the water from the dental chair units. Conclusion: It seems that water coming from the dental chairs at UDC have the lowest bacterial load than the water obtained from the dental chairs at public and private clinics. The reason of high bacterial loads in the private and public clinics could be suboptimal infection control measures in these places. In addition, high bacterial load could be attributed to old pipe system and lack of stringent water filtration system within the clinics. Even though the study has shown high levels of bacterial load we cannot conclude that dental unit water is considered to be a risk for immunocompromised patients. This is because of, no attempt has been done to identify, what kind of bacteria that are present in the water and if these bacteria are pathogenic or not.
format Master Thesis
author Lilleng, Helga
Gangsø, Luise
Skoglund, Julie
author_facet Lilleng, Helga
Gangsø, Luise
Skoglund, Julie
author_sort Lilleng, Helga
title Quality of dental unit water at university dental clinic, private and public clinics in Tromsø. Investigation of bacteria levels in water samples in dental chair water lines
title_short Quality of dental unit water at university dental clinic, private and public clinics in Tromsø. Investigation of bacteria levels in water samples in dental chair water lines
title_full Quality of dental unit water at university dental clinic, private and public clinics in Tromsø. Investigation of bacteria levels in water samples in dental chair water lines
title_fullStr Quality of dental unit water at university dental clinic, private and public clinics in Tromsø. Investigation of bacteria levels in water samples in dental chair water lines
title_full_unstemmed Quality of dental unit water at university dental clinic, private and public clinics in Tromsø. Investigation of bacteria levels in water samples in dental chair water lines
title_sort quality of dental unit water at university dental clinic, private and public clinics in tromsø. investigation of bacteria levels in water samples in dental chair water lines
publisher UiT Norges arktiske universitet
publishDate 2017
url https://hdl.handle.net/10037/11565
geographic Tromsø
geographic_facet Tromsø
genre Tromsø
genre_facet Tromsø
op_relation https://hdl.handle.net/10037/11565
op_rights openAccess
Copyright 2017 The Author(s)
_version_ 1766219464373698560