Monitoring kraft recovery boiler fouling using principal component analysis

Researchers analyzed high resolution operational data from three recovery boilers using the princi - pal component analysis (PCA) feature of a multivariate statistical analysis program to identify major operating varia - bles that contributed to fouling and plugging. The results show that PCA can be...

Full description

Bibliographic Details
Main Authors: Versteeg, Peter, Tran, Honghi
Format: Article in Journal/Newspaper
Language:English
Published: TAPPI Press 2009
Subjects:
Online Access:http://hdl.handle.net/1807/98522
id ftunivtoronto:oai:localhost:1807/98522
record_format openpolar
spelling ftunivtoronto:oai:localhost:1807/98522 2023-05-15T17:54:50+02:00 Monitoring kraft recovery boiler fouling using principal component analysis Versteeg, Peter Tran, Honghi 2009-11 http://hdl.handle.net/1807/98522 en_ca eng TAPPI Press Versteeg, P. & Tran, H. TAPPI J. 8(11):(2009). 0734-1415 http://hdl.handle.net/1807/98522 Article 2009 ftunivtoronto 2020-06-17T12:28:51Z Researchers analyzed high resolution operational data from three recovery boilers using the princi - pal component analysis (PCA) feature of a multivariate statistical analysis program to identify major operating varia - bles that contributed to fouling and plugging. The results show that PCA can be used to visualize the variability relat - ed to long-term fouling trends in the boilers and to graphically distinguish changes in the boiler fouling condition caused by operational variability over a short period. This represents a major step forward in identifying operating variables that might be adjusted to minimize fouling, and in developing an on-line fouling monitoring technology based on PCA. This work was conducted as part of the research program on “Increasing energy and chemical recovery efficiency in the kraft process,” jointly supported by the Natural Sciences and Engineering Research Council of Canada (NSERC) and a con - sortium of the following companies: AbitibiBowater, Alstom Power, Andritz, Aracruz Celulose, Babcock & Wilcox, Boise Paper Solutions, Carter Holt Harvey, Celulose Nipo-Brasileira, Clyde-Bergemann, Diamond Power International, Domtar, DMI Peace River Pulp, Georgia Pacific, International Paper, Irving Pulp & Paper, Metso Power, MeadWestvaco, Stora Enso Research, Tembec, and Votorantim Celulose e Papel. Article in Journal/Newspaper Peace River University of Toronto: Research Repository T-Space Canada Pacific Wilcox ENVELOPE(-66.933,-66.933,-67.949,-67.949)
institution Open Polar
collection University of Toronto: Research Repository T-Space
op_collection_id ftunivtoronto
language English
description Researchers analyzed high resolution operational data from three recovery boilers using the princi - pal component analysis (PCA) feature of a multivariate statistical analysis program to identify major operating varia - bles that contributed to fouling and plugging. The results show that PCA can be used to visualize the variability relat - ed to long-term fouling trends in the boilers and to graphically distinguish changes in the boiler fouling condition caused by operational variability over a short period. This represents a major step forward in identifying operating variables that might be adjusted to minimize fouling, and in developing an on-line fouling monitoring technology based on PCA. This work was conducted as part of the research program on “Increasing energy and chemical recovery efficiency in the kraft process,” jointly supported by the Natural Sciences and Engineering Research Council of Canada (NSERC) and a con - sortium of the following companies: AbitibiBowater, Alstom Power, Andritz, Aracruz Celulose, Babcock & Wilcox, Boise Paper Solutions, Carter Holt Harvey, Celulose Nipo-Brasileira, Clyde-Bergemann, Diamond Power International, Domtar, DMI Peace River Pulp, Georgia Pacific, International Paper, Irving Pulp & Paper, Metso Power, MeadWestvaco, Stora Enso Research, Tembec, and Votorantim Celulose e Papel.
format Article in Journal/Newspaper
author Versteeg, Peter
Tran, Honghi
spellingShingle Versteeg, Peter
Tran, Honghi
Monitoring kraft recovery boiler fouling using principal component analysis
author_facet Versteeg, Peter
Tran, Honghi
author_sort Versteeg, Peter
title Monitoring kraft recovery boiler fouling using principal component analysis
title_short Monitoring kraft recovery boiler fouling using principal component analysis
title_full Monitoring kraft recovery boiler fouling using principal component analysis
title_fullStr Monitoring kraft recovery boiler fouling using principal component analysis
title_full_unstemmed Monitoring kraft recovery boiler fouling using principal component analysis
title_sort monitoring kraft recovery boiler fouling using principal component analysis
publisher TAPPI Press
publishDate 2009
url http://hdl.handle.net/1807/98522
long_lat ENVELOPE(-66.933,-66.933,-67.949,-67.949)
geographic Canada
Pacific
Wilcox
geographic_facet Canada
Pacific
Wilcox
genre Peace River
genre_facet Peace River
op_relation Versteeg, P. & Tran, H. TAPPI J. 8(11):(2009).
0734-1415
http://hdl.handle.net/1807/98522
_version_ 1766162688447086592