Improved analysis of volatile halogenated hydrocarbons in water by purge-and-trap with gas chromatography and mass spectrometric detection

An analytical system composed of a purge-and-trap injection system coupled to gas chromatography with mass spectrometric detection (PTI-GC-MS) specific for the analysis of volatile chlorinated hydrocarbons (VCHCs) (chloroform; 1, 1, 1-trichloroethane; tetrachloromethane; 1, 1,2-trichloroethylene; te...

Full description

Bibliographic Details
Published in:Journal of Chromatography A
Main Authors: ZOCCOLILLO, Lelio, INSOGNA, SUSANNA, Luca Amendola, Claudia Cafaro
Other Authors: Zoccolillo, Lelio, Luca, Amendola, Claudia, Cafaro, Insogna, Susanna
Format: Article in Journal/Newspaper
Language:English
Published: ELSEVIER SCIENCE BV 2005
Subjects:
Online Access:http://hdl.handle.net/11573/17215
https://doi.org/10.1016/j.chroma.2005.04.076
http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=000229945600010&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=0c7ff228ccbaaa74236f48834a34396a
id ftunivromairis:oai:iris.uniroma1.it:11573/17215
record_format openpolar
spelling ftunivromairis:oai:iris.uniroma1.it:11573/17215 2024-04-14T08:03:17+00:00 Improved analysis of volatile halogenated hydrocarbons in water by purge-and-trap with gas chromatography and mass spectrometric detection ZOCCOLILLO, Lelio INSOGNA, SUSANNA Luca Amendola Claudia Cafaro Zoccolillo, Lelio Luca, Amendola Claudia, Cafaro Insogna, Susanna 2005 http://hdl.handle.net/11573/17215 https://doi.org/10.1016/j.chroma.2005.04.076 http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=000229945600010&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=0c7ff228ccbaaa74236f48834a34396a eng eng ELSEVIER SCIENCE BV info:eu-repo/semantics/altIdentifier/pmid/16001554 info:eu-repo/semantics/altIdentifier/wos/WOS:000229945600010 volume:1077 issue:2 firstpage:181 lastpage:187 numberofpages:7 journal:JOURNAL OF CHROMATOGRAPHY A http://hdl.handle.net/11573/17215 doi:10.1016/j.chroma.2005.04.076 info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-19544392154 http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=000229945600010&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=0c7ff228ccbaaa74236f48834a34396a pti-gc-m volatile halogenated compound water analysis info:eu-repo/semantics/article 2005 ftunivromairis https://doi.org/10.1016/j.chroma.2005.04.076 2024-03-21T18:56:10Z An analytical system composed of a purge-and-trap injection system coupled to gas chromatography with mass spectrometric detection (PTI-GC-MS) specific for the analysis of volatile chlorinated hydrocarbons (VCHCs) (chloroform; 1, 1, 1-trichloroethane; tetrachloromethane; 1, 1,2-trichloroethylene; tetrachloroethylene) and trihalomethanes (THMs) (chloroform; bromodichloromethane; dibromochloromethane; bromoform) in water was optimised. Samples were purged and trapped in a cold trap (-100 degrees C) fed with liquid nitrogen (cryo-concentration). In order to make this method suitable also for only slightly contaminated waters, some modifications were made to PTI sample introduction, in order to avoid any air intake into the system. PTI, GC and MS conditions were optimised for halogenated compound analysis and limits of detection (LOD) were evaluated. The proposed method allows analysis of samples whose concentrations range from mu g/L to ng/L. It is, therefore, applicable to drinking waters, in analyses required by law, and to slightly contaminated aqueous matrices, such as those found in remote areas, in environmental monitoring. Moreover, by changing cold trap temperature, even sparkling mineral waters can be analysed, thus avoiding CO2 interference during the cryo-concentration phase. Our method has been successfully used on real samples: tap Water, mineral water and Antarctic snow. (C) 2005 Elsevier B.V. All rights reserved. Article in Journal/Newspaper Antarc* Antarctic Sapienza Università di Roma: CINECA IRIS Antarctic Journal of Chromatography A 1077 2 181 187
institution Open Polar
collection Sapienza Università di Roma: CINECA IRIS
op_collection_id ftunivromairis
language English
topic pti-gc-m
volatile halogenated compound
water analysis
spellingShingle pti-gc-m
volatile halogenated compound
water analysis
ZOCCOLILLO, Lelio
INSOGNA, SUSANNA
Luca Amendola
Claudia Cafaro
Improved analysis of volatile halogenated hydrocarbons in water by purge-and-trap with gas chromatography and mass spectrometric detection
topic_facet pti-gc-m
volatile halogenated compound
water analysis
description An analytical system composed of a purge-and-trap injection system coupled to gas chromatography with mass spectrometric detection (PTI-GC-MS) specific for the analysis of volatile chlorinated hydrocarbons (VCHCs) (chloroform; 1, 1, 1-trichloroethane; tetrachloromethane; 1, 1,2-trichloroethylene; tetrachloroethylene) and trihalomethanes (THMs) (chloroform; bromodichloromethane; dibromochloromethane; bromoform) in water was optimised. Samples were purged and trapped in a cold trap (-100 degrees C) fed with liquid nitrogen (cryo-concentration). In order to make this method suitable also for only slightly contaminated waters, some modifications were made to PTI sample introduction, in order to avoid any air intake into the system. PTI, GC and MS conditions were optimised for halogenated compound analysis and limits of detection (LOD) were evaluated. The proposed method allows analysis of samples whose concentrations range from mu g/L to ng/L. It is, therefore, applicable to drinking waters, in analyses required by law, and to slightly contaminated aqueous matrices, such as those found in remote areas, in environmental monitoring. Moreover, by changing cold trap temperature, even sparkling mineral waters can be analysed, thus avoiding CO2 interference during the cryo-concentration phase. Our method has been successfully used on real samples: tap Water, mineral water and Antarctic snow. (C) 2005 Elsevier B.V. All rights reserved.
author2 Zoccolillo, Lelio
Luca, Amendola
Claudia, Cafaro
Insogna, Susanna
format Article in Journal/Newspaper
author ZOCCOLILLO, Lelio
INSOGNA, SUSANNA
Luca Amendola
Claudia Cafaro
author_facet ZOCCOLILLO, Lelio
INSOGNA, SUSANNA
Luca Amendola
Claudia Cafaro
author_sort ZOCCOLILLO, Lelio
title Improved analysis of volatile halogenated hydrocarbons in water by purge-and-trap with gas chromatography and mass spectrometric detection
title_short Improved analysis of volatile halogenated hydrocarbons in water by purge-and-trap with gas chromatography and mass spectrometric detection
title_full Improved analysis of volatile halogenated hydrocarbons in water by purge-and-trap with gas chromatography and mass spectrometric detection
title_fullStr Improved analysis of volatile halogenated hydrocarbons in water by purge-and-trap with gas chromatography and mass spectrometric detection
title_full_unstemmed Improved analysis of volatile halogenated hydrocarbons in water by purge-and-trap with gas chromatography and mass spectrometric detection
title_sort improved analysis of volatile halogenated hydrocarbons in water by purge-and-trap with gas chromatography and mass spectrometric detection
publisher ELSEVIER SCIENCE BV
publishDate 2005
url http://hdl.handle.net/11573/17215
https://doi.org/10.1016/j.chroma.2005.04.076
http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=000229945600010&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=0c7ff228ccbaaa74236f48834a34396a
geographic Antarctic
geographic_facet Antarctic
genre Antarc*
Antarctic
genre_facet Antarc*
Antarctic
op_relation info:eu-repo/semantics/altIdentifier/pmid/16001554
info:eu-repo/semantics/altIdentifier/wos/WOS:000229945600010
volume:1077
issue:2
firstpage:181
lastpage:187
numberofpages:7
journal:JOURNAL OF CHROMATOGRAPHY A
http://hdl.handle.net/11573/17215
doi:10.1016/j.chroma.2005.04.076
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-19544392154
http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=000229945600010&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=0c7ff228ccbaaa74236f48834a34396a
op_doi https://doi.org/10.1016/j.chroma.2005.04.076
container_title Journal of Chromatography A
container_volume 1077
container_issue 2
container_start_page 181
op_container_end_page 187
_version_ 1796299543059365888