Calibration and design of the E and B EXperiment (EBEX) cryogenic receiver

University of Minnesota Ph.D. dissertation. August 2014. Major: Physics. Advisor: Professor Shaul Hanany. 1 computer file (PDF); ix, 144 pages. I discuss the design, construction, and calibration of the E \& B EXperiment (EBEX), a balloon-borne telescope designed to measure the B-mode polarizati...

Full description

Bibliographic Details
Main Author: Zilic, Kyle Thomas
Format: Thesis
Language:English
Published: 2014
Subjects:
CMB
Online Access:http://hdl.handle.net/11299/167703
id ftunivminnesdc:oai:conservancy.umn.edu:11299/167703
record_format openpolar
spelling ftunivminnesdc:oai:conservancy.umn.edu:11299/167703 2023-05-15T14:02:12+02:00 Calibration and design of the E and B EXperiment (EBEX) cryogenic receiver Zilic, Kyle Thomas 2014-08 http://hdl.handle.net/11299/167703 en eng http://hdl.handle.net/11299/167703 B-mode Calibration CMB Cosmology Inflation Telescope Physics Thesis or Dissertation 2014 ftunivminnesdc 2020-02-02T14:46:27Z University of Minnesota Ph.D. dissertation. August 2014. Major: Physics. Advisor: Professor Shaul Hanany. 1 computer file (PDF); ix, 144 pages. I discuss the design, construction, and calibration of the E \& B EXperiment (EBEX), a balloon-borne telescope designed to measure the B-mode polarization anisotropy of the cosmic microwave background (CMB). EBEX observes the sky with 8 arcmin resolution in three frequency bands centered on 150, 250, and 410 GHz, with over 1,500 detectors. Polarimetry is performed through use of a continuously rotating achromatic half-wave plate with fixed wire-grid polarizer. The experiment was designed to detect the gravitational-lensed B-mode signal and detect or set an upper limit for the inflationary B-mode signal. In this thesis, I describe the design and structure of various subsystems of the EBEX receiver and predict their experimental performance. Several calibrating instrumental response experiments are described and the results reported and compared to predictions. A brief review of the 2012-2013 long duration balloon (LDB) flight from McMurdo Station, Antarctica, is provided and a summary of the receiver performance during flight characterized. Thesis Antarc* Antarctica University of Minnesota Digital Conservancy McMurdo Station ENVELOPE(166.667,166.667,-77.850,-77.850)
institution Open Polar
collection University of Minnesota Digital Conservancy
op_collection_id ftunivminnesdc
language English
topic B-mode
Calibration
CMB
Cosmology
Inflation
Telescope
Physics
spellingShingle B-mode
Calibration
CMB
Cosmology
Inflation
Telescope
Physics
Zilic, Kyle Thomas
Calibration and design of the E and B EXperiment (EBEX) cryogenic receiver
topic_facet B-mode
Calibration
CMB
Cosmology
Inflation
Telescope
Physics
description University of Minnesota Ph.D. dissertation. August 2014. Major: Physics. Advisor: Professor Shaul Hanany. 1 computer file (PDF); ix, 144 pages. I discuss the design, construction, and calibration of the E \& B EXperiment (EBEX), a balloon-borne telescope designed to measure the B-mode polarization anisotropy of the cosmic microwave background (CMB). EBEX observes the sky with 8 arcmin resolution in three frequency bands centered on 150, 250, and 410 GHz, with over 1,500 detectors. Polarimetry is performed through use of a continuously rotating achromatic half-wave plate with fixed wire-grid polarizer. The experiment was designed to detect the gravitational-lensed B-mode signal and detect or set an upper limit for the inflationary B-mode signal. In this thesis, I describe the design and structure of various subsystems of the EBEX receiver and predict their experimental performance. Several calibrating instrumental response experiments are described and the results reported and compared to predictions. A brief review of the 2012-2013 long duration balloon (LDB) flight from McMurdo Station, Antarctica, is provided and a summary of the receiver performance during flight characterized.
format Thesis
author Zilic, Kyle Thomas
author_facet Zilic, Kyle Thomas
author_sort Zilic, Kyle Thomas
title Calibration and design of the E and B EXperiment (EBEX) cryogenic receiver
title_short Calibration and design of the E and B EXperiment (EBEX) cryogenic receiver
title_full Calibration and design of the E and B EXperiment (EBEX) cryogenic receiver
title_fullStr Calibration and design of the E and B EXperiment (EBEX) cryogenic receiver
title_full_unstemmed Calibration and design of the E and B EXperiment (EBEX) cryogenic receiver
title_sort calibration and design of the e and b experiment (ebex) cryogenic receiver
publishDate 2014
url http://hdl.handle.net/11299/167703
long_lat ENVELOPE(166.667,166.667,-77.850,-77.850)
geographic McMurdo Station
geographic_facet McMurdo Station
genre Antarc*
Antarctica
genre_facet Antarc*
Antarctica
op_relation http://hdl.handle.net/11299/167703
_version_ 1766272312178376704