Image quality of late gadolinium enhancement in cardiac magnetic resonance with different doses of contrast material in patients with chronic myocardial infarction

Background: Contrast-enhanced cardiac magnetic resonance (CMR) is pivotal for evaluating chronic myocardial infarction (CMI). Concerns about safety of gadolinium-based contrast agents favour dose reduction. We assessed image quality of scar tissue in CMRs performed with different doses of gadobutrol...

Full description

Bibliographic Details
Published in:European Radiology Experimental
Main Authors: Monti C. B., Codari M., Cozzi A., Ali M., Saggiante L., Sardanelli F., Secchi F.
Other Authors: C.B. Monti, M. Codari, A. Cozzi, M. Ali, L. Saggiante, F. Sardanelli, F. Secchi
Format: Article in Journal/Newspaper
Language:English
Published: Springer 2020
Subjects:
Online Access:http://hdl.handle.net/2434/733620
https://doi.org/10.1186/s41747-020-00149-2
id ftunivmilanoair:oai:air.unimi.it:2434/733620
record_format openpolar
spelling ftunivmilanoair:oai:air.unimi.it:2434/733620 2024-02-04T10:04:20+01:00 Image quality of late gadolinium enhancement in cardiac magnetic resonance with different doses of contrast material in patients with chronic myocardial infarction Monti C. B. Codari M. Cozzi A. Ali M. Saggiante L. Sardanelli F. Secchi F. C.B. Monti M. Codari A. Cozzi M. Ali L. Saggiante F. Sardanelli F. Secchi 2020-04-03 http://hdl.handle.net/2434/733620 https://doi.org/10.1186/s41747-020-00149-2 eng eng Springer info:eu-repo/semantics/altIdentifier/pmid/32242266 info:eu-repo/semantics/altIdentifier/wos/WOS:000705622900001 volume:4 issue:1 firstpage:1 lastpage:9 numberofpages:9 journal:EUROPEAN RADIOLOGY EXPERIMENTAL http://hdl.handle.net/2434/733620 doi:10.1186/s41747-020-00149-2 info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85082953802 info:eu-repo/semantics/openAccess Contrast media Gadobutrol Gadolinium Magnetic resonance imaging Myocardial infarction Settore MED/36 - Diagnostica per Immagini e Radioterapia info:eu-repo/semantics/article 2020 ftunivmilanoair https://doi.org/10.1186/s41747-020-00149-2 2024-01-09T23:42:21Z Background: Contrast-enhanced cardiac magnetic resonance (CMR) is pivotal for evaluating chronic myocardial infarction (CMI). Concerns about safety of gadolinium-based contrast agents favour dose reduction. We assessed image quality of scar tissue in CMRs performed with different doses of gadobutrol in CMI patients. Methods: Informed consent was waived for this Ethics Committee-approved single-centre retrospective study. Consecutive contrast-enhanced CMRs from CMI patients were retrospectively analysed according to the administered gadobutrol dose (group A, 0.10 mmol/kg; group B, 0.15 mmol/kg; group C, 0.20 mmol/kg). We calculated the signal-to-noise ratio for scar tissue (SNRscar) and contrast-to-noise ratio between scar and either remote myocardium (CNRscar-rem) or blood (CNRscar-blood). Results: Of 79 CMRs from 79 patients, 22 belonged to group A, 26 to group B, and 31 to group C. The groups were homogeneous for age, sex, left ventricular morpho-functional parameters, and percentage of scar tissue over whole myocardium (p ≥ 0.300). SNRscar was lower in group A (46.4; 40.3–65.1) than in group B (70.1; 52.2–111.5) (p = 0.013) and group C (72.1; 59.4–100.0) (p = 0.002), CNRscar-rem was lower in group A (62.9; 52.2–87.4) than in group B (96.5; 73.1–152.8) (p = 0.008) and in group C (103.9; 83.9–132.0) (p = 0.001). No other significant differences were found (p ≥ 0.335). Conclusions: Gadobutrol at 0.10 mmol/kg provides inferior scar image quality of CMI than 0.15 and 0.20 mmol/kg; the last two dosages seem to provide similar LGE. Thus, for CMR of CMI, 0.15 mmol/kg of gadobutrol can be suggested instead of 0.20 mmol/kg, with no hindrance to scar visualisation. Dose reduction would not impact on diagnostic utility of CMR examinations. Article in Journal/Newspaper SCAR The University of Milan: Archivio Istituzionale della Ricerca (AIR) European Radiology Experimental 4 1
institution Open Polar
collection The University of Milan: Archivio Istituzionale della Ricerca (AIR)
op_collection_id ftunivmilanoair
language English
topic Contrast media
Gadobutrol
Gadolinium
Magnetic resonance imaging
Myocardial infarction
Settore MED/36 - Diagnostica per Immagini e Radioterapia
spellingShingle Contrast media
Gadobutrol
Gadolinium
Magnetic resonance imaging
Myocardial infarction
Settore MED/36 - Diagnostica per Immagini e Radioterapia
Monti C. B.
Codari M.
Cozzi A.
Ali M.
Saggiante L.
Sardanelli F.
Secchi F.
Image quality of late gadolinium enhancement in cardiac magnetic resonance with different doses of contrast material in patients with chronic myocardial infarction
topic_facet Contrast media
Gadobutrol
Gadolinium
Magnetic resonance imaging
Myocardial infarction
Settore MED/36 - Diagnostica per Immagini e Radioterapia
description Background: Contrast-enhanced cardiac magnetic resonance (CMR) is pivotal for evaluating chronic myocardial infarction (CMI). Concerns about safety of gadolinium-based contrast agents favour dose reduction. We assessed image quality of scar tissue in CMRs performed with different doses of gadobutrol in CMI patients. Methods: Informed consent was waived for this Ethics Committee-approved single-centre retrospective study. Consecutive contrast-enhanced CMRs from CMI patients were retrospectively analysed according to the administered gadobutrol dose (group A, 0.10 mmol/kg; group B, 0.15 mmol/kg; group C, 0.20 mmol/kg). We calculated the signal-to-noise ratio for scar tissue (SNRscar) and contrast-to-noise ratio between scar and either remote myocardium (CNRscar-rem) or blood (CNRscar-blood). Results: Of 79 CMRs from 79 patients, 22 belonged to group A, 26 to group B, and 31 to group C. The groups were homogeneous for age, sex, left ventricular morpho-functional parameters, and percentage of scar tissue over whole myocardium (p ≥ 0.300). SNRscar was lower in group A (46.4; 40.3–65.1) than in group B (70.1; 52.2–111.5) (p = 0.013) and group C (72.1; 59.4–100.0) (p = 0.002), CNRscar-rem was lower in group A (62.9; 52.2–87.4) than in group B (96.5; 73.1–152.8) (p = 0.008) and in group C (103.9; 83.9–132.0) (p = 0.001). No other significant differences were found (p ≥ 0.335). Conclusions: Gadobutrol at 0.10 mmol/kg provides inferior scar image quality of CMI than 0.15 and 0.20 mmol/kg; the last two dosages seem to provide similar LGE. Thus, for CMR of CMI, 0.15 mmol/kg of gadobutrol can be suggested instead of 0.20 mmol/kg, with no hindrance to scar visualisation. Dose reduction would not impact on diagnostic utility of CMR examinations.
author2 C.B. Monti
M. Codari
A. Cozzi
M. Ali
L. Saggiante
F. Sardanelli
F. Secchi
format Article in Journal/Newspaper
author Monti C. B.
Codari M.
Cozzi A.
Ali M.
Saggiante L.
Sardanelli F.
Secchi F.
author_facet Monti C. B.
Codari M.
Cozzi A.
Ali M.
Saggiante L.
Sardanelli F.
Secchi F.
author_sort Monti C. B.
title Image quality of late gadolinium enhancement in cardiac magnetic resonance with different doses of contrast material in patients with chronic myocardial infarction
title_short Image quality of late gadolinium enhancement in cardiac magnetic resonance with different doses of contrast material in patients with chronic myocardial infarction
title_full Image quality of late gadolinium enhancement in cardiac magnetic resonance with different doses of contrast material in patients with chronic myocardial infarction
title_fullStr Image quality of late gadolinium enhancement in cardiac magnetic resonance with different doses of contrast material in patients with chronic myocardial infarction
title_full_unstemmed Image quality of late gadolinium enhancement in cardiac magnetic resonance with different doses of contrast material in patients with chronic myocardial infarction
title_sort image quality of late gadolinium enhancement in cardiac magnetic resonance with different doses of contrast material in patients with chronic myocardial infarction
publisher Springer
publishDate 2020
url http://hdl.handle.net/2434/733620
https://doi.org/10.1186/s41747-020-00149-2
genre SCAR
genre_facet SCAR
op_relation info:eu-repo/semantics/altIdentifier/pmid/32242266
info:eu-repo/semantics/altIdentifier/wos/WOS:000705622900001
volume:4
issue:1
firstpage:1
lastpage:9
numberofpages:9
journal:EUROPEAN RADIOLOGY EXPERIMENTAL
http://hdl.handle.net/2434/733620
doi:10.1186/s41747-020-00149-2
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85082953802
op_rights info:eu-repo/semantics/openAccess
op_doi https://doi.org/10.1186/s41747-020-00149-2
container_title European Radiology Experimental
container_volume 4
container_issue 1
_version_ 1789972734793482240