Cryoballoon ablation for atrial fibrillation guided by real-time three-dimensional transoesophageal echocardiography : a feasibility study

Aims Cryoballoon ablation (CBA; Arctic Front, Medtronic) has proven very effective in achieving pulmonary vein isolation. Real-time three-dimensional transoesophageal echocardiography (RT 3D TEE) is a novel technology, which permits detailed visualization of cardiac structures in a 3D perspective. T...

Full description

Bibliographic Details
Published in:EP Europace
Main Authors: L. Ottaviano, G. Chierchia, N. Bruno, A. Antonelli, A. T. A. Alsheraei, A. M. Porrini, E. Gronda, A. Duijnhower, P. Brugada, A. S. Montenero, A. Bregasi, F. Donatelli
Other Authors: A.T.A. Alsheraei, A.M. Porrini, A.S. Montenero
Format: Article in Journal/Newspaper
Language:English
Published: Oxford Journals 2013
Subjects:
Online Access:http://hdl.handle.net/2434/226365
https://doi.org/10.1093/europace/eus431
_version_ 1821840999488421888
author L. Ottaviano
G. Chierchia
N. Bruno
A. Antonelli
A. T. A. Alsheraei
A. M. Porrini
E. Gronda
A. Duijnhower
P. Brugada
A. S. Montenero
A. Bregasi
F. Donatelli
author2 L. Ottaviano
G. Chierchia
A. Bregasi
N. Bruno
A. Antonelli
A.T.A. Alsheraei
A.M. Porrini
E. Gronda
F. Donatelli
A. Duijnhower
P. Brugada
A.S. Montenero
author_facet L. Ottaviano
G. Chierchia
N. Bruno
A. Antonelli
A. T. A. Alsheraei
A. M. Porrini
E. Gronda
A. Duijnhower
P. Brugada
A. S. Montenero
A. Bregasi
F. Donatelli
author_sort L. Ottaviano
collection The University of Milan: Archivio Istituzionale della Ricerca (AIR)
container_issue 7
container_start_page 944
container_title EP Europace
container_volume 15
description Aims Cryoballoon ablation (CBA; Arctic Front, Medtronic) has proven very effective in achieving pulmonary vein isolation. Real-time three-dimensional transoesophageal echocardiography (RT 3D TEE) is a novel technology, which permits detailed visualization of cardiac structures in a 3D perspective. The aim of the present study was to assess the feasibility, advantages, and safety of RT 3D TEE in guiding CBA in a series of patients affected by paroxysmal atrial fibrillation. Methods and results Forty-five patients (34 males, mean age: 63 ± 12 years) underwent CBA guided by 3D TEE. A total of 190 veins could be documented by TEE. Real-time three-dimensional transoesophageal echocardiography successfully guided the operator to position the CB in the pulmonary vein (PV) ostium and obtain complete occlusion in all 190 (100%) veins. Transoesophageal echocardiography identified leakages in 25 (13%) veins led to successful elimination of PV–left atrium (LA) backflow by guiding correct balloon repositioning. In four (2%) veins, this imaging tool led to perform successful pull-down manoeuvres. After a mean 2.6 ± 1.4 applications, isolation could be documented in 190 (100%) PVs. Median procedural and fluoroscopy times were 145 and 24 min. During a median follow-up of 278 days, 37 (82%) patients did not experience atrial fibrillation recurrence following a 3-month blanking period. Conclusion Cryoballoon ablation is safe and feasible under RT 3D TEE guidance. This imaging tool permits perfect visualization of all PV ostia and neighbouring LA structures. Most importantly, it proved very efficient in guiding the operator to achieve complete occlusion and successful isolation in all veins.
format Article in Journal/Newspaper
genre Arctic
genre_facet Arctic
geographic Arctic
geographic_facet Arctic
id ftunivmilanoair:oai:air.unimi.it:2434/226365
institution Open Polar
language English
op_collection_id ftunivmilanoair
op_container_end_page 950
op_doi https://doi.org/10.1093/europace/eus431
op_relation info:eu-repo/semantics/altIdentifier/pmid/23430006
info:eu-repo/semantics/altIdentifier/wos/WOS:000320858100007
volume:15
issue:7
firstpage:944
lastpage:950
numberofpages:7
journal:EUROPACE
http://hdl.handle.net/2434/226365
doi:10.1093/europace/eus431
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84879570044
op_rights info:eu-repo/semantics/closedAccess
publishDate 2013
publisher Oxford Journals
record_format openpolar
spelling ftunivmilanoair:oai:air.unimi.it:2434/226365 2025-01-16T20:46:01+00:00 Cryoballoon ablation for atrial fibrillation guided by real-time three-dimensional transoesophageal echocardiography : a feasibility study L. Ottaviano G. Chierchia N. Bruno A. Antonelli A. T. A. Alsheraei A. M. Porrini E. Gronda A. Duijnhower P. Brugada A. S. Montenero A. Bregasi F. Donatelli L. Ottaviano G. Chierchia A. Bregasi N. Bruno A. Antonelli A.T.A. Alsheraei A.M. Porrini E. Gronda F. Donatelli A. Duijnhower P. Brugada A.S. Montenero 2013-07 http://hdl.handle.net/2434/226365 https://doi.org/10.1093/europace/eus431 eng eng Oxford Journals info:eu-repo/semantics/altIdentifier/pmid/23430006 info:eu-repo/semantics/altIdentifier/wos/WOS:000320858100007 volume:15 issue:7 firstpage:944 lastpage:950 numberofpages:7 journal:EUROPACE http://hdl.handle.net/2434/226365 doi:10.1093/europace/eus431 info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84879570044 info:eu-repo/semantics/closedAccess 3D TEE Atrial fibrillation ablation Cryoballoon Settore MED/11 - Malattie dell'Apparato Cardiovascolare Settore MED/23 - Chirurgia Cardiaca info:eu-repo/semantics/article 2013 ftunivmilanoair https://doi.org/10.1093/europace/eus431 2024-01-23T23:28:00Z Aims Cryoballoon ablation (CBA; Arctic Front, Medtronic) has proven very effective in achieving pulmonary vein isolation. Real-time three-dimensional transoesophageal echocardiography (RT 3D TEE) is a novel technology, which permits detailed visualization of cardiac structures in a 3D perspective. The aim of the present study was to assess the feasibility, advantages, and safety of RT 3D TEE in guiding CBA in a series of patients affected by paroxysmal atrial fibrillation. Methods and results Forty-five patients (34 males, mean age: 63 ± 12 years) underwent CBA guided by 3D TEE. A total of 190 veins could be documented by TEE. Real-time three-dimensional transoesophageal echocardiography successfully guided the operator to position the CB in the pulmonary vein (PV) ostium and obtain complete occlusion in all 190 (100%) veins. Transoesophageal echocardiography identified leakages in 25 (13%) veins led to successful elimination of PV–left atrium (LA) backflow by guiding correct balloon repositioning. In four (2%) veins, this imaging tool led to perform successful pull-down manoeuvres. After a mean 2.6 ± 1.4 applications, isolation could be documented in 190 (100%) PVs. Median procedural and fluoroscopy times were 145 and 24 min. During a median follow-up of 278 days, 37 (82%) patients did not experience atrial fibrillation recurrence following a 3-month blanking period. Conclusion Cryoballoon ablation is safe and feasible under RT 3D TEE guidance. This imaging tool permits perfect visualization of all PV ostia and neighbouring LA structures. Most importantly, it proved very efficient in guiding the operator to achieve complete occlusion and successful isolation in all veins. Article in Journal/Newspaper Arctic The University of Milan: Archivio Istituzionale della Ricerca (AIR) Arctic EP Europace 15 7 944 950
spellingShingle 3D TEE
Atrial fibrillation ablation
Cryoballoon
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Settore MED/23 - Chirurgia Cardiaca
L. Ottaviano
G. Chierchia
N. Bruno
A. Antonelli
A. T. A. Alsheraei
A. M. Porrini
E. Gronda
A. Duijnhower
P. Brugada
A. S. Montenero
A. Bregasi
F. Donatelli
Cryoballoon ablation for atrial fibrillation guided by real-time three-dimensional transoesophageal echocardiography : a feasibility study
title Cryoballoon ablation for atrial fibrillation guided by real-time three-dimensional transoesophageal echocardiography : a feasibility study
title_full Cryoballoon ablation for atrial fibrillation guided by real-time three-dimensional transoesophageal echocardiography : a feasibility study
title_fullStr Cryoballoon ablation for atrial fibrillation guided by real-time three-dimensional transoesophageal echocardiography : a feasibility study
title_full_unstemmed Cryoballoon ablation for atrial fibrillation guided by real-time three-dimensional transoesophageal echocardiography : a feasibility study
title_short Cryoballoon ablation for atrial fibrillation guided by real-time three-dimensional transoesophageal echocardiography : a feasibility study
title_sort cryoballoon ablation for atrial fibrillation guided by real-time three-dimensional transoesophageal echocardiography : a feasibility study
topic 3D TEE
Atrial fibrillation ablation
Cryoballoon
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Settore MED/23 - Chirurgia Cardiaca
topic_facet 3D TEE
Atrial fibrillation ablation
Cryoballoon
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Settore MED/23 - Chirurgia Cardiaca
url http://hdl.handle.net/2434/226365
https://doi.org/10.1093/europace/eus431